Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2024  Not logged in ELOG logo
Message ID: 376     Entry time: Sat Apr 27 09:29:54 2024
Author: tb-crew 
Subject: HV scan (hi range) 
Run Number: 335 
DUT: W8 LIV 
Fluence: unirradiated 
Beam Energy: 4.2 
Data: Unknown 
t-Start: 26.04.2024 23:40:34 
t-Stop: 27.04.2024 09:30:14 
Duration_min: 589 
automatic log for run 335
Comment:
HV = -190V, overnight
Attachment 1: peary_config.cfg  1 kB  | Show | Hide all | Show all
Attachment 2: matrix_mpw4.txt  382 Bytes  | Hide | Hide all | Show all
# Config-File of the Pixel-Matrix; generated by MPW3-Config-Creator
# each line represents the configuration of an individual pixel
# format: {row} {col} {masked} {en_inj} {en_hb} {en_sfout} {trimDAC} 

# default values (which are not printed) are:
# {row} {col} 0 0 0 0 -1 
13 04 1 0 0 0 -1 
20 38 1 0 0 0 -1 
36 16 1 0 0 0 -1 
48 54 1 0 0 0 -1 
57 39 1 0 0 0 -1 
60 00 1 0 0 0 -1 
Attachment 3: mpw4.conf  4 kB  | Show | Hide all | Show all
ELOG V3.1.5-fc6679b