Message ID: 371     Entry time: Fri Apr 26 23:21:13 2024
Author: tb-crew 
Subject: HV scan (hi range) 
Run Number: 333 
DUT: W3 LIV 
Fluence: unirradiated 
Beam Energy: 4.2 
Data: Unknown 
t-Start: 26.04.2024 23:17:16 
t-Stop: 26.04.2024 23:21:33 
Duration_min:
automatic log for run 333
Comment:
telepix masking happening
Attachment 1: peary_config.cfg  1 kB  | Show | Hide all | Show all
Attachment 2: matrix_mpw4.txt  940 Bytes  | Hide | Hide all | Show all
# Config-File of the Pixel-Matrix; generated by MPW3-Config-Creator
# each line represents the configuration of an individual pixel
# format: {row} {col} {masked} {en_inj} {en_hb} {en_sfout} {trimDAC} 

# default values (which are not printed) are:
# {row} {col} 0 0 0 0 -1 
00 28 1 0 0 0 -1 
00 36 1 0 0 0 -1 
02 43 1 0 0 0 -1 
03 13 1 0 0 0 -1 
05 00 1 0 0 0 -1 
05 52 1 0 0 0 -1 
06 60 1 0 0 0 -1 
08 20 1 0 0 0 -1 
10 42 1 0 0 0 -1 
12 48 1 0 0 0 -1 
12 61 1 0 0 0 -1 
13 56 1 0 0 0 -1 
14 57 1 0 0 0 -1 
15 60 1 0 0 0 -1 
18 01 1 0 0 0 -1 
18 20 1 0 0 0 -1 
20 55 1 0 0 0 -1 
22 04 1 0 0 0 -1 
22 10 1 0 0 0 -1 
22 58 1 0 0 0 -1 
23 52 1 0 0 0 -1 
25 56 1 0 0 0 -1 
27 47 1 0 0 0 -1 
29 30 1 0 0 0 -1 
31 55 1 0 0 0 -1 
35 30 1 0 0 0 -1 
36 62 1 0 0 0 -1 
38 16 1 0 0 0 -1 
39 11 1 0 0 0 -1 
41 44 1 0 0 0 -1 
48 50 1 0 0 0 -1 
50 16 1 0 0 0 -1 
51 00 1 0 0 0 -1 
52 00 1 0 0 0 -1 
54 08 1 0 0 0 -1 
60 54 1 0 0 0 -1 
60 59 1 0 0 0 -1 
Attachment 3: mpw4.conf  4 kB  | Show | Hide all | Show all