Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2024  Not logged in ELOG logo
Message ID: 240     Entry time: Thu Apr 25 03:31:24 2024
Author: tb-crew 
Subject: threshold scan 
Run Number: 221 
DUT: Wxxx backside 
Fluence: unirradiated 
Beam Energy: 4.2 
Data: Unknown 
t-Start: 25.04.2024 03:11:39 
t-Stop: 25.04.2024 03:31:42 
Duration_min: 20 
automatic log for run 221
Comment:
Attachment 1: peary_config.cfg  1 kB  | Show | Hide all | Show all
Attachment 2: matrix_mpw4.txt  64 kB  | Show | Hide all | Show all
Attachment 3: default_15.conf  2 kB  | Hide | Hide all | Show all
Name = /home/silicon/RD50-MPW4/tb_desy_apr24/mpw4.conf

[DataCollector.mpw4_dc]
DISABLE_PRINT = 1
EUDAQ_DATACOL_SEND_MONITOR_FRACTION = 100
EUDAQ_FW = native
EUDAQ_FW_PATTERN = /media/silicon/testbeam_data/desy2404/mpw4_run$6R$X
EUDAQ_MN = mpw4_mon
XILINX_IP = 192.168.201.1

[DataCollector.tel_dc]
DISABLE_PRINT = 1
EUDAQ_FW = native
EUDAQ_FW_PATTERN = /data1/rd50-mpw4/adenium/adenium_run$6R$X

[DataCollector.tlu_dc]
DISABLE_PRINT = 1
EUDAQ_FW = native
EUDAQ_FW_PATTERN = /data1/rd50-mpw4/tlu/tlu_run$6R$X

[LogCollector.log]

[Monitor.mpw4_mon]
buffer_size = 50000
update_thr = 50

[Producer.MuPix8]
#EUDAQ_DC = tel_dc
#lazyFrog = -25
#register_value = 0
ThPix = 144

[Producer.RD50_MPW4_0]
voltage_key = th
voltage_value = 1.16

[Producer.aida_tlu]
#  Clock source (0 = no clock, 1= Si5345, 2= FPGA)
# Generate internal triggers (in Hz, 0 = no triggers)
# In EUDET mode: 0 = standard trigger/busy mode, 1 = raising BUSY outside handshake vetoes triggers (2 bits per DUT, 0x3= DUT 4! -backwards!)
#DUTMask = 0x3
#DUTMaskModeModifier = 0x30
#PMT1_V = 0.8
#PMT2_V = 0.85
#PMT3_V = 0.8
#PMT4_V = 0.0
#trigMaskLo = 0x00000040
DACThreshold0 = +0.3
DACThreshold1 = -0.04
DACThreshold2 = -0.04
DACThreshold3 = +0.5
DACThreshold4 = -0.12
DACThreshold5 = -0.12
DUTIgnoreBusy = 0x0
DUTIgnoreShutterVeto = 0x0
DUTMask = 0xD
DUTMaskMode = 0xF1
EUDAQ_DC = tlu_dc
EnableRecordData = 1
EnableShutterMode = 0x0
FileComment = mpw3
HDMI1_clk = 1
HDMI1_set = 0x7
HDMI2_clk = 1
HDMI2_set = 0x7
HDMI3_clk = 1
HDMI3_set = 0x7
HDMI4_clk = 1
HDMI4_set = 0x7
InternalShutterInterval = 0
InternalTriggerFreq = 0
LEMOclk = 0
MinSpillTimeOnins = 4.5
MinSpilldownTimeins = 0.5
PlotWindowSizeinns = 40e9
ShutterOffTime = 200000000
ShutterOnTime = 0
ShutterSource = 5
ShutterVetoOffTime = 0
ThreshEvBegin = 1
ThreshEvEnd = 1
ThreshPartBegin = 1
ThreshPartEnd = 1
confid = 20201311
delayStart = 200
in0_DEL = 0
in0_STR = 0x3F
in1_DEL = 0
in1_STR = 1
in2_DEL = 0
in2_STR = 0x3F
in3_DEL = 0
in3_STR = 1
in4_DEL = 0
in4_STR = 0
in5_DEL = 0
in5_STR = 0
skipconf = 0
trigMaskHi = 0x00000000
trigMaskLo = 0x00000002
trigPol = 0x3E
verbose = 1

[Producer.altel]
EUDAQ_DC = tel_dc
EUDAQ_ID = 1

[Producer.elog1]
files2log = "peary_config.cfg, matrix_mpw4.txt"
start_cmd = "./get_mpw4_configs.sh"

[Producer.keithleyPS]
max_current = 15e-6
voltage = -210

[RunControl]
#EUDAQ_CTRL_PRODUCER_FIRST_STOP = my_pd0
#EUDAQ_CTRL_PRODUCER_LAST_START = my_pd0
#pCT_STOP_RUN_AFTER_N_SECONDS = 3000000
ADDITIONAL_DISPLAY_NUMBERS = log,_SERVER