Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2024  Not logged in ELOG logo
Message ID: 213     Entry time: Wed Apr 24 17:01:47 2024
Author: RD50 Generic User 
Subject:  
Run Number:  
DUT:  
Fluence:  
Beam Energy:  
Data:  
t-Start:  
t-Stop:  
Duration_min:  

geo for rotated sample, 20 degrees still need to be added to the DUT (x -> 200)

full aligned

mask

Attachment 1: detectors_rotated.geo  2 kB  | Hide | Hide all | Show all
[Adenium_0]
coordinates = "cartesian"
material_budget = 0.00075
number_of_pixels = 1024, 512
orientation = 0deg,0deg,0deg
orientation_mode = "xyz"
pixel_pitch = 29.24um,26.88um
position = 0um,0um,0mm
spatial_resolution = 8.441um,7.76um
time_resolution = 10us
type = "adenium"

[Adenium_1]
coordinates = "cartesian"
material_budget = 0.00075
number_of_pixels = 1024, 512
orientation = 0deg,0deg,0deg
orientation_mode = "xyz"
pixel_pitch = 29.24um,26.88um
position = 0um,0um,26mm
spatial_resolution = 8.441um,7.76um
time_resolution = 10us
type = "adenium"

[Adenium_2]
coordinates = "cartesian"
material_budget = 0.00075
number_of_pixels = 1024, 512
orientation = 0deg,0deg,0deg
orientation_mode = "xyz"
pixel_pitch = 29.24um,26.88um
position = 0um,0um,52mm
role = "reference"
spatial_resolution = 8.441um,7.76um
time_resolution = 10us
type = "adenium"

[RD50_MPWx_base_0]
mask_file = mask_hephy_topside.txt
coordinates = "cartesian"
material_budget = 0.0032
number_of_pixels = 64, 64
orientation = 180deg,20deg,-90deg
orientation_mode = "xyz"
pixel_pitch = 62um,62um
position = 0mm,0um,90mm
role = "dut"
spatial_resolution = 17.898um,17.898um
time_resolution = 50ns
type = "rd50_mpwx"

[Adenium_3]
coordinates = "cartesian"
material_budget = 0.00075
number_of_pixels = 1024, 512
orientation = 0deg,0deg,0deg
orientation_mode = "xyz"
pixel_pitch = 29.24um,26.88um
position = 0um,0um,187mm
spatial_resolution = 8.441um,7.76um
time_resolution = 10us
type = "adenium"

[Adenium_4]
coordinates = "cartesian"
material_budget = 0.00075
number_of_pixels = 1024, 512
orientation = 0deg,0deg,0deg
orientation_mode = "xyz"
pixel_pitch = 29.24um,26.88um
position = 0um,0um,213mm
spatial_resolution = 8.441um,7.76um
time_resolution = 10us
type = "adenium"

[Adenium_5]
coordinates = "cartesian"
material_budget = 0.00075
number_of_pixels = 1024, 512
orientation = 0deg,0deg,0deg
orientation_mode = "xyz"
pixel_pitch = 29.24um,26.88um
position = 0um,0um,239mm
spatial_resolution = 8.441um,7.76um
time_resolution = 10us
type = "adenium"

[TLU_0]
coordinates = "cartesian"
number_of_pixels = 0, 0
orientation = 0.138197deg,-0deg,0deg
orientation_mode = "xyz"
pixel_pitch = 0um,0um
position = -48.379um,0um,50000mm
spatial_resolution = 0um,0um
time_resolution = 1ns
type = "tlu"

Attachment 2: full_aligned_backside_hephy_rotated_run_199.geo  2 kB  Uploaded Fri Apr 26 11:52:45 2024  | Show | Hide all | Show all
Attachment 3: mask_hephy_backside.txt  248 Bytes  Uploaded Fri Apr 26 11:52:45 2024  | Show | Hide all | Show all
ELOG V3.1.5-fc6679b