  77   Wed Oct 26 08:00:03 2022 RD50 Generic UserEnd of SuccessHEPHY_DUT11.2FEi4 | Mimosa949-977 111mm/77.75mmGoodGreetings from Berhard, Christian and Patrick
from CERN H6B ;)

 
  
  76   Wed Oct 26 07:58:43 2022 RD50 Generic UserLong night runsHEPHY_DUT11.2FEi4 | Mimosa949-977 111mm/77.75mmGoodwith new Firmware, streched t0   
  75   Tue Oct 25 16:50:02 2022 RD50 Generic UserSyncable Data RunHEPHY_DUT11.2FEi4 | Mimosa941-948 111mm/77.75mmGoodwith new Firmware, streched t0   
  74   Tue Oct 25 11:53:44 2022 RD50 Generic UserSyncable Data RunHEPHY_DUT11.2FEi4 | Mimosa940 111mm/77.75mmGoodwith new Firmware, streched t0, 10min run
for loading into corry
  
  73   Tue Oct 25 11:44:25 2022 RD50 Generic UserSyncable Data RunHEPHY_DUT11.2FEi4 | Mimosa939 111mm/77.75mmGoodwith new Firmware, streched t0, short run   
  72   Tue Oct 25 11:44:20 2022 RD50 Generic UserSyncable Data RunHEPHY_DUT11.2FEi4 | Mimosa938 111mm/77.75mmGoodwith new Firmware, streched t0, short run   
  71   Tue Oct 25 11:43:45 2022 RD50 Generic UserSyncable Data RunHEPHY_DUT11.2FEi4 | Mimosa937 111mm/77.75mmGoodwith new Firmware, streched t0, short run   
  70   Tue Oct 25 11:43:01 2022 RD50 Generic UserNight runs with 1min noiseHEPHY_DUT11.2FEi4 | Mimosa925-936 111mm/77.75mmCraptesting t0   
  69   Tue Oct 25 11:42:29 2022 RD50 Generic UserNight runs with 1min noiseHEPHY_DUT11.2FEi4 | Mimosa910-925 111mm/77.75mmUnknownshort runs for t0 tests and 30s noise test   
  68   Tue Oct 25 01:29:03 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa906-909 111mm/77.75mmUnknownshort runs for t0 tests and 30s noise test   
  67   Tue Oct 25 01:07:36 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa905 111mm/77.75mmUnknownshort run for t0 tests, start during spill   
  66   Tue Oct 25 01:07:26 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa904 111mm/77.75mmUnknownshort run for t0 tests   
  65   Tue Oct 25 01:04:20 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa900-903 111mm/77.75mmUnknownshort run for t0 tests   
  64   Tue Oct 25 00:15:19 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa899 111mm/77.75mmUnknownshort run for t0 tests   
  63   Tue Oct 25 00:15:09 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa898 111mm/77.75mmUnknownshort run for t0 tests   
  62   Mon Oct 24 23:38:51 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa897 111mm/77.75mmUnknownshort run with new 1us UDP query again...   
  61   Mon Oct 24 23:38:21 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa896 111mm/77.75mmUnknownshort run with old 100us UDP query   
  60   Mon Oct 24 23:37:48 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa884-895 111mm/77.75mmCrapstart/stop for testing t0   
  59   Mon Oct 24 22:39:44 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa883 111mm/77.75mmUnknownshortrun for checking after powercycling
ZYNC
  
  58   Mon Oct 24 22:39:23 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa874-882 111mm/77.75mmUnknown    
  57   Mon Oct 24 18:34:25 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa873 111mm/77.75mmCrappressed start too early   
  56   Mon Oct 24 18:33:15 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa872 111mm/77.75mmGoodshort run for t0 check   
  55   Mon Oct 24 18:10:56 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa871 111mm/77.75mmCrapno beam, checking....   
  54   Mon Oct 24 18:01:34 2022 RD50 Generic UserSyncable data runHEPHY_DUT21.2FEi4 | Mimosa870 111mm/77.75mmGoodno t0, screw in hephy 1 again   
  53   Mon Oct 24 18:00:40 2022 RD50 Generic UserSyncable data runHEPHY_DUT21.2FEi4 | Mimosa869 111mm/77.75mmGoodshort testrun for bernhard if he can see
t0

DUT exchange, IFIC_DUT has t0 connected
  
  52   Mon Oct 24 17:29:14 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa868 111mm/77.75mmGood 

 
  
  51   Mon Oct 24 17:29:07 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa867 111mm/77.75mmGood 

 
  
  50   Mon Oct 24 17:29:02 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa866 111mm/77.75mmGood 

 
  
  49   Mon Oct 24 17:28:53 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa865 111mm/77.75mmGood 

 
  
  48   Mon Oct 24 15:19:00 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa864 111mm/77.75mmGoodRun with new DUT

 
  
  47   Mon Oct 24 15:18:26 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa863 111mm/77.75mmCrapEUDAQ crashed

 
  
  46   Mon Oct 24 15:10:11 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa858-862 111mm/77.75mmGoodAccess to change DUT after 862

 
  
  45   Mon Oct 24 11:50:11 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa857 111mm/77.75mmGoodaccess ended for 136 beam again for run
starting 857

 
  
  44   Mon Oct 24 11:06:01 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa856 111mm/77.75mmGoodaccess again for 136

 
  
  43   Mon Oct 24 10:56:49 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa856 111mm/77.75mmGoodaccess ended at 10:56

beam again for run 856 onwards

 
  
  42   Mon Oct 24 09:26:01 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa826-852 111mm/77.75mmGoodarrived at 9:24

overnight the automate script has
created 27 runs
  
  41   Sun Oct 23 18:22:38 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa825 111mm/77.75mmGoodDUT changed to Ricardo1

-> maybe re-align telescope
  
  40   Sun Oct 23 18:22:23 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa824 111mm/77.75mmGood    
  39   Sun Oct 23 18:22:13 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa823 111mm/77.75mmGood    
  38   Sun Oct 23 16:46:05 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa822 111mm/77.75mmGoodLong run

stopped for access

 
  
  37   Sun Oct 23 15:35:42 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGoodLong run

FEI4 crashed

restarted
  
  Draft   Sun Oct 23 15:14:30 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGood    
  35   Sun Oct 23 15:14:09 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGoodLong one, stopped for access of the other
users
  
  34   Sun Oct 23 13:48:33 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa820 111mm/77.75mmGoodLong one, stopped for access of the other
users
  
  33   Sun Oct 23 12:06:50 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa819 111mm/77.75mmGoodLong one, stopped for access of the other
users
  
  32   Sun Oct 23 11:31:58 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa818 111mm/77.75mmUnknownanother short one because the fei4 is so
reliable :)
  
  31   Sun Oct 23 11:29:43 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa817 111mm/77.75mmGoodanother short one because the fei4 is so
reliable :)
  
  30   Sun Oct 23 11:18:19 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa816 111mm/77.75mmGoodshort run from 11:10 to 11:18

 

fei4 crashed
  
  29   Sun Oct 23 11:14:44 2022 RD50 Generic Userbeam start time       beam stared at 11:10 events and particles
counting up
  
  28   Sun Oct 23 10:07:44 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa815 111mm/77.75mmGoodOvernight run

New Firmware with 64bit TS

FEI4 with busy (with timing for
  
  27   Sat Oct 22 21:11:13 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa814 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  26   Sat Oct 22 21:11:04 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa813 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  25   Sat Oct 22 21:10:24 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa810-812 111mm/77.75mmCrapNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  24   Sat Oct 22 16:42:51 2022 Christian IrmlerMikrotik Router Confignone      Backup of Mikrotik Router configuration.

Binary and rules as script
 rd50_tb_h6b-20221022.backuprd50_tb-h6b-20221022.rsc 
  23   Sat Oct 22 14:55:06 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa809 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  22   Sat Oct 22 14:07:34 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa808 111mm/77.75mmUnknownRepeat of ID 20 as it was interrupted

New Firmware with 64bit TS

FEI4 without busy
  
  21   Sat Oct 22 11:36:53 2022 RD50 Generic Usert0 testsHEPHY_DUT11.2FEi4 | Mimosa786-807 111mm/77.75mmCrapt0 tests   
  20   Sat Oct 22 10:01:21 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa785 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 without busy
(test if the FEI4 kills th run)
  
  19   Sat Oct 22 09:33:06 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa784 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  18   Sat Oct 22 09:30:17 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa781-783 111mm/77.75mmCrapSystem test checking if the TLU sends triggers
without terminating the Runcontrol (answer:
No)
  
  17   Fri Oct 21 19:23:28 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa780 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  16   Fri Oct 21 19:22:44 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa779 111mm/77.75mmCrapNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  15   Fri Oct 21 19:07:50 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa778 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  14   Fri Oct 21 18:59:05 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa777 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  13   Fri Oct 21 18:37:26 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa776 111mm/77.75mmCrapNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  12   Fri Oct 21 18:36:50 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa775 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 without busy (no timing for
tracking)
  
  11   Fri Oct 21 15:25:54 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa760-774 111mm/77.75mmCrapSystem test   
  10   Fri Oct 21 15:24:45 2022 RD50 Generic Usershort data run with CPU TSHEPHY_DUT11.2FEi4 | Mimosa759 111mm/77.75mmGoodshould be the correct run, maybe it was
another. Firmware and software with CPU TS
  
  9   Fri Oct 21 15:24:04 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa757-758 111mm/77.75mmCrapSystem test   
  8   Fri Oct 21 13:31:58 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa753-756 111mm/77.75mmCrapSystem test   
  7   Fri Oct 21 10:49:30 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa752 111mm/77.75mmCrapSystem test   
  6   Fri Oct 21 10:49:15 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa751 111mm/77.75mmCrapSystem test   
  5   Fri Oct 21 10:48:24 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa750 111mm/77.75mmCrapSystem test   
  4   Thu Oct 20 22:18:23 2022 RD50 Generic Usernight run with DUTHEPHY_DUT11.2FEi4 | Mimosa7491.25M111mm/77.75mmGoodOld software version -> No timestamp
overflow or 64bit counter

Will try to fix software tomorrow
  
  3   Thu Oct 20 22:06:26 2022 RD50 Generic Usernight run with DUTHEPHY_DUT11.2FEi4 | Mimosa74862k on TLU111mm/77.75mmGoodOld software version -> No timestamp
overflow or 64bit counter

Will try to fix software tomorrow
  
  2   Thu Oct 20 22:05:18 2022 RD50 Generic Usershort test with FEI4none-FEi4 | Mimosa747 111mm/77.75mmGoodNeeds to be checked for data integrity
with FEI4
  
  1   Thu Oct 20 22:00:22 2022 RD50 Generic UserLong Night Run (Mimosa)none-Mimosa710 111mm/77.75mmGoodNeeds to be checked for data integrity   