Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  RD50 MPW3 Beamtest at CERN SPS, Page 4 of 4  Not logged in ELOG logo
ID Date Author Subjectdown DUT Threshold RefDetectors Run Number Events XYPosition Data Text Attachments
  11   Fri Oct 21 15:25:54 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa760-774 111mm/77.75mmCrapSystem test   
  18   Sat Oct 22 09:30:17 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa781-783 111mm/77.75mmCrapSystem test checking if the TLU sends triggers
without terminating the Runcontrol (answer:
No)
  
  69   Tue Oct 25 11:42:29 2022 RD50 Generic UserNight runs with 1min noiseHEPHY_DUT11.2FEi4 | Mimosa910-925 111mm/77.75mmUnknownshort runs for t0 tests and 30s noise test   
  70   Tue Oct 25 11:43:01 2022 RD50 Generic UserNight runs with 1min noiseHEPHY_DUT11.2FEi4 | Mimosa925-936 111mm/77.75mmCraptesting t0   
  15   Fri Oct 21 19:07:50 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa778 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  16   Fri Oct 21 19:22:44 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa779 111mm/77.75mmCrapNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  17   Fri Oct 21 19:23:28 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa780 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  19   Sat Oct 22 09:33:06 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa784 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  20   Sat Oct 22 10:01:21 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa785 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 without busy
(test if the FEI4 kills th run)
  
  22   Sat Oct 22 14:07:34 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa808 111mm/77.75mmUnknownRepeat of ID 20 as it was interrupted

New Firmware with 64bit TS

FEI4 without busy
  
  24   Sat Oct 22 16:42:51 2022 Christian IrmlerMikrotik Router Confignone      Backup of Mikrotik Router configuration.

Binary and rules as script
 rd50_tb_h6b-20221022.backuprd50_tb-h6b-20221022.rsc 
  76   Wed Oct 26 07:58:43 2022 RD50 Generic UserLong night runsHEPHY_DUT11.2FEi4 | Mimosa949-977 111mm/77.75mmGoodwith new Firmware, streched t0   
  1   Thu Oct 20 22:00:22 2022 RD50 Generic UserLong Night Run (Mimosa)none-Mimosa710 111mm/77.75mmGoodNeeds to be checked for data integrity   
  12   Fri Oct 21 18:36:50 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa775 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 without busy (no timing for
tracking)
  
  13   Fri Oct 21 18:37:26 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa776 111mm/77.75mmCrapNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  14   Fri Oct 21 18:59:05 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa777 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  77   Wed Oct 26 08:00:03 2022 RD50 Generic UserEnd of SuccessHEPHY_DUT11.2FEi4 | Mimosa949-977 111mm/77.75mmGoodGreetings from Berhard, Christian and Patrick
from CERN H6B ;)

 
  
ELOG V3.1.5-fc6679b