Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  RD50 MPW3 Beamtest at CERN SPS, Page 3 of 4  Not logged in ELOG logo
ID Date Author Subject DUTdown Threshold RefDetectors Run Number Events XYPosition Data Text Attachments
  27   Sat Oct 22 21:11:13 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa814 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  28   Sun Oct 23 10:07:44 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa815 111mm/77.75mmGoodOvernight run

New Firmware with 64bit TS

FEI4 with busy (with timing for
  
  30   Sun Oct 23 11:18:19 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa816 111mm/77.75mmGoodshort run from 11:10 to 11:18

 

fei4 crashed
  
  31   Sun Oct 23 11:29:43 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa817 111mm/77.75mmGoodanother short one because the fei4 is so
reliable :)
  
  32   Sun Oct 23 11:31:58 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa818 111mm/77.75mmUnknownanother short one because the fei4 is so
reliable :)
  
  33   Sun Oct 23 12:06:50 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa819 111mm/77.75mmGoodLong one, stopped for access of the other
users
  
  34   Sun Oct 23 13:48:33 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa820 111mm/77.75mmGoodLong one, stopped for access of the other
users
  
  35   Sun Oct 23 15:14:09 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGoodLong one, stopped for access of the other
users
  
  Draft   Sun Oct 23 15:14:30 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGood    
  37   Sun Oct 23 15:35:42 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGoodLong run

FEI4 crashed

restarted
  
  38   Sun Oct 23 16:46:05 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa822 111mm/77.75mmGoodLong run

stopped for access

 
  
  39   Sun Oct 23 18:22:13 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa823 111mm/77.75mmGood    
  40   Sun Oct 23 18:22:23 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa824 111mm/77.75mmGood    
  55   Mon Oct 24 18:10:56 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa871 111mm/77.75mmCrapno beam, checking....   
  56   Mon Oct 24 18:33:15 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa872 111mm/77.75mmGoodshort run for t0 check   
  57   Mon Oct 24 18:34:25 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa873 111mm/77.75mmCrappressed start too early   
  58   Mon Oct 24 22:39:23 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa874-882 111mm/77.75mmUnknown    
  59   Mon Oct 24 22:39:44 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa883 111mm/77.75mmUnknownshortrun for checking after powercycling
ZYNC
  
  60   Mon Oct 24 23:37:48 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa884-895 111mm/77.75mmCrapstart/stop for testing t0   
  61   Mon Oct 24 23:38:21 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa896 111mm/77.75mmUnknownshort run with old 100us UDP query   
ELOG V3.1.5-fc6679b