Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  RD50 MPW3 Beamtest at CERN SPS, Page 3 of 4  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject DUT Threshold RefDetectors Run Number Events XYPosition Data
  37   Sun Oct 23 15:35:42 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGood

Long run

FEI4 crashed

restarted

  Draft   Sun Oct 23 15:14:30 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGood
  35   Sun Oct 23 15:14:09 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGood

Long one, stopped for access of the other users

  34   Sun Oct 23 13:48:33 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa820 111mm/77.75mmGood

Long one, stopped for access of the other users

  33   Sun Oct 23 12:06:50 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa819 111mm/77.75mmGood

Long one, stopped for access of the other users

  32   Sun Oct 23 11:31:58 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa818 111mm/77.75mmUnknown

another short one because the fei4 is so reliable :)

  31   Sun Oct 23 11:29:43 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa817 111mm/77.75mmGood

another short one because the fei4 is so reliable :)

  30   Sun Oct 23 11:18:19 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa816 111mm/77.75mmGood

short run from 11:10 to 11:18

 

fei4 crashed

 

restarted

  29   Sun Oct 23 11:14:44 2022 RD50 Generic Userbeam start time       

beam stared at 11:10 events and particles counting up

  28   Sun Oct 23 10:07:44 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa815 111mm/77.75mmGood

Overnight run

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Should give latest and greatest tracking results :)

 

  27   Sat Oct 22 21:11:13 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa814 111mm/77.75mmGood

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Should give latest and greatest tracking results :)

 

  26   Sat Oct 22 21:11:04 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa813 111mm/77.75mmGood

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Should give latest and greatest tracking results :)

 

  25   Sat Oct 22 21:10:24 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa810-812 111mm/77.75mmCrap

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Should give latest and greatest tracking results :)

 

  24   Sat Oct 22 16:42:51 2022 Christian IrmlerMikrotik Router Confignone      

Backup of Mikrotik Router configuration.

Binary and rules as script

  23   Sat Oct 22 14:55:06 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa809 111mm/77.75mmUnknown

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Should give latest and greatest tracking results :)

 

  22   Sat Oct 22 14:07:34 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa808 111mm/77.75mmUnknown

Repeat of ID 20 as it was interrupted

New Firmware with 64bit TS

FEI4 without busy (test if the FEI4 kills th run)

  21   Sat Oct 22 11:36:53 2022 RD50 Generic Usert0 testsHEPHY_DUT11.2FEi4 | Mimosa786-807 111mm/77.75mmCrap

t0 tests

  20   Sat Oct 22 10:01:21 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa785 111mm/77.75mmUnknown

New Firmware with 64bit TS

FEI4 without busy (test if the FEI4 kills th run)

  19   Sat Oct 22 09:33:06 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa784 111mm/77.75mmUnknown

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Repeat of night run.

 

End of Run comment: Stopped after half hour, same issue as before

  18   Sat Oct 22 09:30:17 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa781-783 111mm/77.75mmCrap

System test checking if the TLU sends triggers without terminating the Runcontrol (answer: No)

ELOG V3.1.5-fc6679b