Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  RD50 MPW3 Beamtest at CERN SPS, Page 1 of 4  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject DUT Threshold RefDetectorsdown Run Number Events XYPosition Data
  1   Thu Oct 20 22:00:22 2022 RD50 Generic UserLong Night Run (Mimosa)none-Mimosa710 111mm/77.75mmGood

Needs to be checked for data integrity

  2   Thu Oct 20 22:05:18 2022 RD50 Generic Usershort test with FEI4none-FEi4 | Mimosa747 111mm/77.75mmGood

Needs to be checked for data integrity with FEI4

  3   Thu Oct 20 22:06:26 2022 RD50 Generic Usernight run with DUTHEPHY_DUT11.2FEi4 | Mimosa74862k on TLU111mm/77.75mmGood

Old software version -> No timestamp overflow or 64bit counter

Will try to fix software tomorrow

Mimosen are not in the mood of sending data -> restart mimosen

Data should be good

  4   Thu Oct 20 22:18:23 2022 RD50 Generic Usernight run with DUTHEPHY_DUT11.2FEi4 | Mimosa7491.25M111mm/77.75mmGood

Old software version -> No timestamp overflow or 64bit counter

Will try to fix software tomorrow

  5   Fri Oct 21 10:48:24 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa750 111mm/77.75mmCrap

System test

  6   Fri Oct 21 10:49:15 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa751 111mm/77.75mmCrap

System test

  7   Fri Oct 21 10:49:30 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa752 111mm/77.75mmCrap

System test

  8   Fri Oct 21 13:31:58 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa753-756 111mm/77.75mmCrap

System test

  9   Fri Oct 21 15:24:04 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa757-758 111mm/77.75mmCrap

System test

  10   Fri Oct 21 15:24:45 2022 RD50 Generic Usershort data run with CPU TSHEPHY_DUT11.2FEi4 | Mimosa759 111mm/77.75mmGood

should be the correct run, maybe it was another. Firmware and software with CPU TS

  11   Fri Oct 21 15:25:54 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa760-774 111mm/77.75mmCrap

System test

  12   Fri Oct 21 18:36:50 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa775 111mm/77.75mmGood

New Firmware with 64bit TS

FEI4 without busy (no timing for tracking)

  13   Fri Oct 21 18:37:26 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa776 111mm/77.75mmCrap

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

FEI4 crashed -> restart

  14   Fri Oct 21 18:59:05 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa777 111mm/77.75mmGood

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

  15   Fri Oct 21 19:07:50 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa778 111mm/77.75mmGood

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Should give latest and greatest tracking results :)

Mimosa crashing

  16   Fri Oct 21 19:22:44 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa779 111mm/77.75mmCrap

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Should give latest and greatest tracking results :)

No data from mimosa

  17   Fri Oct 21 19:23:28 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa780 111mm/77.75mmUnknown

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Should give latest and greatest tracking results :)

 

End result: AIDA TLU Stopped data taking and sending triggers after  40 minutes. Possible reaso : FEI4 stuck in busy, TLU error (whatever that may have been)

 

  18   Sat Oct 22 09:30:17 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa781-783 111mm/77.75mmCrap

System test checking if the TLU sends triggers without terminating the Runcontrol (answer: No)

  19   Sat Oct 22 09:33:06 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa784 111mm/77.75mmUnknown

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Repeat of night run.

 

End of Run comment: Stopped after half hour, same issue as before

  20   Sat Oct 22 10:01:21 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa785 111mm/77.75mmUnknown

New Firmware with 64bit TS

FEI4 without busy (test if the FEI4 kills th run)

ELOG V3.1.5-fc6679b