1
|
Thu Oct 20 22:00:22 2022 |
RD50 Generic User | Long Night Run (Mimosa) | none | - | Mimosa | 710 | | 111mm/77.75mm | Good |
Needs to be checked for data integrity |
2
|
Thu Oct 20 22:05:18 2022 |
RD50 Generic User | short test with FEI4 | none | - | FEi4 | Mimosa | 747 | | 111mm/77.75mm | Good |
Needs to be checked for data integrity with FEI4 |
3
|
Thu Oct 20 22:06:26 2022 |
RD50 Generic User | night run with DUT | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 748 | 62k on TLU | 111mm/77.75mm | Good |
Old software version -> No timestamp overflow or 64bit counter
Will try to fix software tomorrow
Mimosen are not in the mood of sending data -> restart mimosen
Data should be good |
4
|
Thu Oct 20 22:18:23 2022 |
RD50 Generic User | night run with DUT | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 749 | 1.25M | 111mm/77.75mm | Good |
Old software version -> No timestamp overflow or 64bit counter
Will try to fix software tomorrow |
5
|
Fri Oct 21 10:48:24 2022 |
RD50 Generic User | SYSTEM TEST | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 750 | | 111mm/77.75mm | Crap |
System test |
6
|
Fri Oct 21 10:49:15 2022 |
RD50 Generic User | SYSTEM TEST | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 751 | | 111mm/77.75mm | Crap |
System test |
7
|
Fri Oct 21 10:49:30 2022 |
RD50 Generic User | SYSTEM TEST | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 752 | | 111mm/77.75mm | Crap |
System test |
8
|
Fri Oct 21 13:31:58 2022 |
RD50 Generic User | SYSTEM TEST | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 753-756 | | 111mm/77.75mm | Crap |
System test |
9
|
Fri Oct 21 15:24:04 2022 |
RD50 Generic User | SYSTEM TEST | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 757-758 | | 111mm/77.75mm | Crap |
System test |
10
|
Fri Oct 21 15:24:45 2022 |
RD50 Generic User | short data run with CPU TS | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 759 | | 111mm/77.75mm | Good |
should be the correct run, maybe it was another. Firmware and software with CPU TS |
11
|
Fri Oct 21 15:25:54 2022 |
RD50 Generic User | SYSTEM TEST | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 760-774 | | 111mm/77.75mm | Crap |
System test |
12
|
Fri Oct 21 18:36:50 2022 |
RD50 Generic User | FEI4 busy test | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 775 | | 111mm/77.75mm | Good |
New Firmware with 64bit TS
FEI4 without busy (no timing for tracking) |
13
|
Fri Oct 21 18:37:26 2022 |
RD50 Generic User | FEI4 busy test | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 776 | | 111mm/77.75mm | Crap |
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking)
FEI4 crashed -> restart |
14
|
Fri Oct 21 18:59:05 2022 |
RD50 Generic User | FEI4 busy test | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 777 | | 111mm/77.75mm | Good |
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking) |
15
|
Fri Oct 21 19:07:50 2022 |
RD50 Generic User | Night run test | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 778 | | 111mm/77.75mm | Good |
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking)
Should give latest and greatest tracking results :)
Mimosa crashing |
16
|
Fri Oct 21 19:22:44 2022 |
RD50 Generic User | Night run test | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 779 | | 111mm/77.75mm | Crap |
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking)
Should give latest and greatest tracking results :)
No data from mimosa |
17
|
Fri Oct 21 19:23:28 2022 |
RD50 Generic User | Night run test | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 780 | | 111mm/77.75mm | Unknown |
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking)
Should give latest and greatest tracking results :)
End result: AIDA TLU Stopped data taking and sending triggers after 40 minutes. Possible reaso : FEI4 stuck in busy, TLU error (whatever that may have been)
|
18
|
Sat Oct 22 09:30:17 2022 |
RD50 Generic User | SYSTEM TEST | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 781-783 | | 111mm/77.75mm | Crap |
System test checking if the TLU sends triggers without terminating the Runcontrol (answer: No) |
19
|
Sat Oct 22 09:33:06 2022 |
RD50 Generic User | Night run test | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 784 | | 111mm/77.75mm | Unknown |
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking)
Repeat of night run.
End of Run comment: Stopped after half hour, same issue as before |
20
|
Sat Oct 22 10:01:21 2022 |
RD50 Generic User | Night run test | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 785 | | 111mm/77.75mm | Unknown |
New Firmware with 64bit TS
FEI4 without busy (test if the FEI4 kills th run) |
21
|
Sat Oct 22 11:36:53 2022 |
RD50 Generic User | t0 tests | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 786-807 | | 111mm/77.75mm | Crap |
t0 tests |
22
|
Sat Oct 22 14:07:34 2022 |
RD50 Generic User | Night run test | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 808 | | 111mm/77.75mm | Unknown |
Repeat of ID 20 as it was interrupted
New Firmware with 64bit TS
FEI4 without busy (test if the FEI4 kills th run) |
23
|
Sat Oct 22 14:55:06 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 809 | | 111mm/77.75mm | Unknown |
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking)
Should give latest and greatest tracking results :)
|
25
|
Sat Oct 22 21:10:24 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 810-812 | | 111mm/77.75mm | Crap |
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking)
Should give latest and greatest tracking results :)
|
26
|
Sat Oct 22 21:11:04 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 813 | | 111mm/77.75mm | Good |
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking)
Should give latest and greatest tracking results :)
|
27
|
Sat Oct 22 21:11:13 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 814 | | 111mm/77.75mm | Good |
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking)
Should give latest and greatest tracking results :)
|
28
|
Sun Oct 23 10:07:44 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 815 | | 111mm/77.75mm | Good |
Overnight run
New Firmware with 64bit TS
FEI4 with busy (with timing for tracking)
Should give latest and greatest tracking results :)
|
30
|
Sun Oct 23 11:18:19 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 816 | | 111mm/77.75mm | Good |
short run from 11:10 to 11:18
fei4 crashed
restarted |
31
|
Sun Oct 23 11:29:43 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 817 | | 111mm/77.75mm | Good |
another short one because the fei4 is so reliable :) |
32
|
Sun Oct 23 11:31:58 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 818 | | 111mm/77.75mm | Unknown |
another short one because the fei4 is so reliable :) |
33
|
Sun Oct 23 12:06:50 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 819 | | 111mm/77.75mm | Good |
Long one, stopped for access of the other users |
34
|
Sun Oct 23 13:48:33 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 820 | | 111mm/77.75mm | Good |
Long one, stopped for access of the other users |
35
|
Sun Oct 23 15:14:09 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 821 | | 111mm/77.75mm | Good |
Long one, stopped for access of the other users |
Draft
|
Sun Oct 23 15:14:30 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 821 | | 111mm/77.75mm | Good |
|
37
|
Sun Oct 23 15:35:42 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 821 | | 111mm/77.75mm | Good |
Long run
FEI4 crashed
restarted |
38
|
Sun Oct 23 16:46:05 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 822 | | 111mm/77.75mm | Good |
Long run
stopped for access
|
39
|
Sun Oct 23 18:22:13 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 823 | | 111mm/77.75mm | Good |
|
40
|
Sun Oct 23 18:22:23 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 824 | | 111mm/77.75mm | Good |
|
41
|
Sun Oct 23 18:22:38 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT2 | 1.2 | FEi4 | Mimosa | 825 | | 111mm/77.75mm | Good |
DUT changed to Ricardo1
-> maybe re-align telescope |
42
|
Mon Oct 24 09:26:01 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT2 | 1.2 | FEi4 | Mimosa | 826-852 | | 111mm/77.75mm | Good |
arrived at 9:24
overnight the automate script has created 27 runs
FEI4 events still counting up
The script works! :) |
43
|
Mon Oct 24 10:56:49 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT2 | 1.2 | FEi4 | Mimosa | 856 | | 111mm/77.75mm | Good |
access ended at 10:56
beam again for run 856 onwards
|
44
|
Mon Oct 24 11:06:01 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT2 | 1.2 | FEi4 | Mimosa | 856 | | 111mm/77.75mm | Good |
access again for 136
|
45
|
Mon Oct 24 11:50:11 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT2 | 1.2 | FEi4 | Mimosa | 857 | | 111mm/77.75mm | Good |
access ended for 136 beam again for run starting 857
|
46
|
Mon Oct 24 15:10:11 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT2 | 1.2 | FEi4 | Mimosa | 858-862 | | 111mm/77.75mm | Good |
Access to change DUT after 862
|
47
|
Mon Oct 24 15:18:26 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT1 | 1.2 | FEi4 | Mimosa | 863 | | 111mm/77.75mm | Crap |
EUDAQ crashed
|
48
|
Mon Oct 24 15:19:00 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT1 | 1.2 | FEi4 | Mimosa | 864 | | 111mm/77.75mm | Good |
Run with new DUT
|
49
|
Mon Oct 24 17:28:53 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT1 | 1.2 | FEi4 | Mimosa | 865 | | 111mm/77.75mm | Good |
|
50
|
Mon Oct 24 17:29:02 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT1 | 1.2 | FEi4 | Mimosa | 866 | | 111mm/77.75mm | Good |
|
51
|
Mon Oct 24 17:29:07 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT1 | 1.2 | FEi4 | Mimosa | 867 | | 111mm/77.75mm | Good |
|
52
|
Mon Oct 24 17:29:14 2022 |
RD50 Generic User | Syncable data run | IFIC_DUT1 | 1.2 | FEi4 | Mimosa | 868 | | 111mm/77.75mm | Good |
|
53
|
Mon Oct 24 18:00:40 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT2 | 1.2 | FEi4 | Mimosa | 869 | | 111mm/77.75mm | Good |
short testrun for bernhard if he can see t0
DUT exchange, IFIC_DUT has t0 connected in wrong way |
54
|
Mon Oct 24 18:01:34 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT2 | 1.2 | FEi4 | Mimosa | 870 | | 111mm/77.75mm | Good |
no t0, screw in hephy 1 again |
55
|
Mon Oct 24 18:10:56 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 871 | | 111mm/77.75mm | Crap |
no beam, checking.... |
56
|
Mon Oct 24 18:33:15 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 872 | | 111mm/77.75mm | Good |
short run for t0 check |
57
|
Mon Oct 24 18:34:25 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 873 | | 111mm/77.75mm | Crap |
pressed start too early |
58
|
Mon Oct 24 22:39:23 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 874-882 | | 111mm/77.75mm | Unknown |
|
59
|
Mon Oct 24 22:39:44 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 883 | | 111mm/77.75mm | Unknown |
shortrun for checking after powercycling ZYNC |
60
|
Mon Oct 24 23:37:48 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 884-895 | | 111mm/77.75mm | Crap |
start/stop for testing t0 |
61
|
Mon Oct 24 23:38:21 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 896 | | 111mm/77.75mm | Unknown |
short run with old 100us UDP query |
62
|
Mon Oct 24 23:38:51 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 897 | | 111mm/77.75mm | Unknown |
short run with new 1us UDP query again... |
63
|
Tue Oct 25 00:15:09 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 898 | | 111mm/77.75mm | Unknown |
short run for t0 tests |
64
|
Tue Oct 25 00:15:19 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 899 | | 111mm/77.75mm | Unknown |
short run for t0 tests |
65
|
Tue Oct 25 01:04:20 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 900-903 | | 111mm/77.75mm | Unknown |
short run for t0 tests |
66
|
Tue Oct 25 01:07:26 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 904 | | 111mm/77.75mm | Unknown |
short run for t0 tests |
67
|
Tue Oct 25 01:07:36 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 905 | | 111mm/77.75mm | Unknown |
short run for t0 tests, start during spill |
68
|
Tue Oct 25 01:29:03 2022 |
RD50 Generic User | Syncable data run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 906-909 | | 111mm/77.75mm | Unknown |
short runs for t0 tests and 30s noise test |
69
|
Tue Oct 25 11:42:29 2022 |
RD50 Generic User | Night runs with 1min noise | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 910-925 | | 111mm/77.75mm | Unknown |
short runs for t0 tests and 30s noise test |
70
|
Tue Oct 25 11:43:01 2022 |
RD50 Generic User | Night runs with 1min noise | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 925-936 | | 111mm/77.75mm | Crap |
testing t0 |
71
|
Tue Oct 25 11:43:45 2022 |
RD50 Generic User | Syncable Data Run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 937 | | 111mm/77.75mm | Good |
with new Firmware, streched t0, short run |
72
|
Tue Oct 25 11:44:20 2022 |
RD50 Generic User | Syncable Data Run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 938 | | 111mm/77.75mm | Good |
with new Firmware, streched t0, short run |
73
|
Tue Oct 25 11:44:25 2022 |
RD50 Generic User | Syncable Data Run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 939 | | 111mm/77.75mm | Good |
with new Firmware, streched t0, short run |
74
|
Tue Oct 25 11:53:44 2022 |
RD50 Generic User | Syncable Data Run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 940 | | 111mm/77.75mm | Good |
with new Firmware, streched t0, 10min run for loading into corry |
75
|
Tue Oct 25 16:50:02 2022 |
RD50 Generic User | Syncable Data Run | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 941-948 | | 111mm/77.75mm | Good |
with new Firmware, streched t0 |
76
|
Wed Oct 26 07:58:43 2022 |
RD50 Generic User | Long night runs | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 949-977 | | 111mm/77.75mm | Good |
with new Firmware, streched t0 |
77
|
Wed Oct 26 08:00:03 2022 |
RD50 Generic User | End of Success | HEPHY_DUT1 | 1.2 | FEi4 | Mimosa | 949-977 | | 111mm/77.75mm | Good |
Greetings from Berhard, Christian and Patrick from CERN H6B ;)
|
24
|
Sat Oct 22 16:42:51 2022 |
Christian Irmler | Mikrotik Router Config | none | | | | | | |
Backup of Mikrotik Router configuration.
Binary and rules as script |
29
|
Sun Oct 23 11:14:44 2022 |
RD50 Generic User | beam start time | | | | | | | |
beam stared at 11:10 events and particles counting up |