Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  RD50 MPW3 Beamtest at CERN SPS, Page 1 of 4  Not logged in ELOG logo
ID Date Author Subject DUTdown Threshold RefDetectors Run Number Events XYPosition Data
  1   Thu Oct 20 22:00:22 2022 RD50 Generic UserLong Night Run (Mimosa)none-Mimosa710 111mm/77.75mmGood

Needs to be checked for data integrity

  2   Thu Oct 20 22:05:18 2022 RD50 Generic Usershort test with FEI4none-FEi4 | Mimosa747 111mm/77.75mmGood

Needs to be checked for data integrity with FEI4

  24   Sat Oct 22 16:42:51 2022 Christian IrmlerMikrotik Router Confignone      

Backup of Mikrotik Router configuration.

Binary and rules as script

  41   Sun Oct 23 18:22:38 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa825 111mm/77.75mmGood

DUT changed to Ricardo1

-> maybe re-align telescope

  42   Mon Oct 24 09:26:01 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa826-852 111mm/77.75mmGood

arrived at 9:24

overnight the automate script has created 27 runs

FEI4 events still counting up

The script works! :)

  43   Mon Oct 24 10:56:49 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa856 111mm/77.75mmGood

access ended at 10:56

beam again for run 856 onwards

 

 

  44   Mon Oct 24 11:06:01 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa856 111mm/77.75mmGood

access again for 136

 

  45   Mon Oct 24 11:50:11 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa857 111mm/77.75mmGood

access ended for 136 beam again for run starting 857

 

  46   Mon Oct 24 15:10:11 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa858-862 111mm/77.75mmGood

Access to change DUT after 862

 

  47   Mon Oct 24 15:18:26 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa863 111mm/77.75mmCrap

EUDAQ crashed

 

  48   Mon Oct 24 15:19:00 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa864 111mm/77.75mmGood

Run with new DUT

 

  49   Mon Oct 24 17:28:53 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa865 111mm/77.75mmGood

 

 

  50   Mon Oct 24 17:29:02 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa866 111mm/77.75mmGood

 

 

  51   Mon Oct 24 17:29:07 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa867 111mm/77.75mmGood

 

 

  52   Mon Oct 24 17:29:14 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa868 111mm/77.75mmGood

 

 

  53   Mon Oct 24 18:00:40 2022 RD50 Generic UserSyncable data runHEPHY_DUT21.2FEi4 | Mimosa869 111mm/77.75mmGood

short testrun for bernhard if he can see t0

DUT exchange, IFIC_DUT has t0 connected in wrong way

  54   Mon Oct 24 18:01:34 2022 RD50 Generic UserSyncable data runHEPHY_DUT21.2FEi4 | Mimosa870 111mm/77.75mmGood

no t0, screw in hephy 1 again

  3   Thu Oct 20 22:06:26 2022 RD50 Generic Usernight run with DUTHEPHY_DUT11.2FEi4 | Mimosa74862k on TLU111mm/77.75mmGood

Old software version -> No timestamp overflow or 64bit counter

Will try to fix software tomorrow

Mimosen are not in the mood of sending data -> restart mimosen

Data should be good

  4   Thu Oct 20 22:18:23 2022 RD50 Generic Usernight run with DUTHEPHY_DUT11.2FEi4 | Mimosa7491.25M111mm/77.75mmGood

Old software version -> No timestamp overflow or 64bit counter

Will try to fix software tomorrow

  5   Fri Oct 21 10:48:24 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa750 111mm/77.75mmCrap

System test

ELOG V3.1.5-fc6679b