Sat Jan 17 10:40:24 2026, elog_producer, Rate Test, 8, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Good, 17.01.2026 10:31:12, 17.01.2026 10:40:28, 9, Normal, None,
|
automatic log for run 8
Comment:
trigger window: 85ns post, 1.915 us pre |
Sat Jan 17 10:48:31 2026, elog_producer, Rate Test, 9, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Good, 17.01.2026 10:42:23, 17.01.2026 10:48:35, 6, Normal, None,
|
automatic log for run 9
Comment:
trigger window 85 ns post, 1.915 us pre, 70mb/s events, 15mb/s drop |
Sat Jan 17 10:55:49 2026, elog_producer, Rate Test, 10, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Good, 17.01.2026 10:51:15, 17.01.2026 10:55:53, 4, Normal, None,
|
automatic log for run 10
Comment:
trigger window 85 ns post, 640 ns pre, 52mb/s events, 4mb/s drop, 9E+6 particle rate ramon |
Sat Jan 17 11:00:50 2026, elog_producer, Rate Test, 11, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Good, 17.01.2026 10:57:22, 17.01.2026 11:00:54, 3, Normal, None,
|
automatic log for run 11
Comment:
trigger window 85ns post, 2.915 us pre, 80mb/s events, 25mb/s drop, 9E+6 particle rate ramon |
Sat Jan 17 11:06:15 2026, elog_producer, Rate Test, 12, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Good, 17.01.2026 11:02:01, 17.01.2026 11:06:19, 4, Normal, None,
|
automatic log for run 12
Comment:
trigger window 85ns post, 3.915 us pre, 100mb/s events, 40mb/s drop, 9E+6 particle rate ramon |
Sat Jan 17 11:13:44 2026, elog_producer, Rate Test, 13, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Good, 17.01.2026 11:06:51, 17.01.2026 11:13:48, 6, Normal, None,
|
automatic log for run 13
Comment:
trigger window 85ns post, 3.915 us pre, 33mb/s events, 1mb/s drop, 4E+6 particle rate ramon |
Sat Jan 17 11:30:05 2026, elog_producer, Rate Test, 14, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Good, 17.01.2026 11:14:46, 17.01.2026 11:30:09, 15, Normal, None,
|
automatic log for run 14
Comment:
trigger window 85ns post, 2.915 us pre, 30mb/s events, 0.6mb/s drop, 4E+6 particle rate ramon |
Sat Jan 17 11:33:33 2026, elog_producer, Rate Test, 15, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Low, Helium, Good, 17.01.2026 11:31:19, 17.01.2026 11:33:37, 2, Normal, None,
|
automatic log for run 15
Comment:
trigger window 85ns post, 2.915 us pre, 25kb/s events, 0mb/s drop, 6E+3 particle rate ramon |
Sun Jun 7 03:44:28 2026, elog_producer, Rate Test, 5, ToF-iCT-Setup + DS LGAD + Ramon, 402MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 03:23:49, 07.06.2026 03:44:40, 20, Normal, None,
|
automatic log for run 5
Comment:
3 us trigger window
110 mb/s /eb
rejected: 70 mb/s |
Sun Jun 7 04:04:12 2026, elog_producer, Rate Test, 6, ToF-iCT-Setup + DS LGAD + Ramon, 402MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 03:52:48, 07.06.2026 04:04:24, 11, Normal, None,
|
automatic log for run 6
Comment:
new threshold scan
trigger window: 200 ns
threshold at 1500 |
Sat Jul 11 19:34:51 2026, elog_producer, Rate Test, 5, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 200 MeV/u, Nominal, Mixed Beam (He+C), Unknown, 11.07.2026 19:01:26, 11.07.2026 19:34:51, 33, Normal, RW3,
|
automatic log for run 5
Comment:
In beam: 3 cm RW3 + PTW34070 Ionization Chamber + 11 cm RW3 + PTW34070 Ionization Chamber + 1 cm RW3
trigger on plane 4
use max rate settings (nominal with 10% He) of mixed beam
rate per strip: 60-90khz for front detector
about MHz per detector
data written: 12MB/s per eb
absolut: 50 MB/s leading |
Sat Jul 11 18:48:23 2026, elog_producer, QA+alignment, 3, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 200 MeV/u, Nominal, Mixed Beam (He+C), Unknown, 11.07.2026 18:19:25, 11.07.2026 18:48:24, 28, Normal, RW3,
|
automatic log for run 3
Comment:
In beam: 3 cm RW3 + PTW34070 Ionization Chamber + 11 cm RW3 + PTW34070 Ionization Chamber + 1 cm RW3
Alignment mixed beam:
y-axis: aligned
x-axis: maximum at strip 18 (setup is 4-5 strips off to the right (beam is left))
SIPM
18:45: thr rescanned |
Sun Jun 7 11:09:39 2026, Harald Handerkas, Phantom iCT runs log entries, 16-295, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 06:49:15, 07.06.2026 11:06:55, 257, Normal, Cylinder with inserts, 
|
| Run settings and log file for runs |
Sun Jun 7 06:48:30 2026, elog_producer, Phantom Testrun without DAQ, 15, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 06:43:51, 07.06.2026 06:48:42, 4, Normal, None,
|
automatic log for run 15
Comment: |
Sun Jun 7 11:06:43 2026, elog_producer, Phantom Testrun without DAQ, 16, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 06:49:15, 07.06.2026 11:06:55, 257, Normal, None,
|
automatic log for run 16
Comment:
iCT tomographie runs |
Sun Jul 12 06:52:16 2026, elog_producer, Head Phantom, 21, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 200 MeV/u, Nominal, Mixed Beam (He+C), Unknown, 12.07.2026 02:20:25, 12.07.2026 06:52:17, 271, Normal, Head, 
|
automatic log for run 21
Comment:
Start automatet Spot measurements of head phantom
2:19: thr were not set correctly, no data at beginning of run 21
2:23: reset trigger window to 3us
runs 21-25 high statistics spots
ab run 81: 1mm Platte zusätzlich |
Sat Jul 11 20:53:37 2026, elog_producer, He Alignment + mixed beam verification, 6, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 402MeV/u, Low Flux High, Helium, Unknown, 11.07.2026 19:45:15, 11.07.2026 20:53:38, 68, Normal, None,
|
automatic log for run 6
Comment:
ohne empty bucket
now ripple filter are in
setup moved by 3mm
moved back by 6mm
He only first sensor: mean is strip 21
last sensor: mean is on strip 19
20:36: go back to mixed beam for verification
alignment looks good for mixed beam |
Sun Jun 7 01:18:32 2026, elog_producer, GSI Sensor Test, 2, ToF-iCT-Setup + DS LGAD + Ramon, 800 MeV, Low Flux High, Proton, Unknown, 07.06.2026 00:37:15, 07.06.2026 01:18:44, 41, Normal, None,
|
automatic log for run 2
Comment: |
Sun Jun 7 02:41:32 2026, elog_producer, GSI Sensor Test, 3, ToF-iCT-Setup + DS LGAD + Ramon, 800 MeV, Low Flux High, Proton, Unknown, 07.06.2026 01:19:47, 07.06.2026 02:41:43, 81, Normal, None,
|
automatic log for run 3
Comment:
Trigger on last detector |
Sat Jul 11 16:26:54 2026, elog_producer, GSI Sensor Test, 1, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 800 MeV, Low Flux High, Proton, Unknown, 11.07.2026 16:17:29, 11.07.2026 16:26:54, 9, Normal, RW3,
|
automatic log for run 1
Comment:
In beam: 3 cm RW3 + PTW34070 Ionization Chamber + 11 cm RW3 + PTW34070 Ionization Chamber + 1 cm RW3
Powersupply failed, restart in next run |
|