Sat Jan 17 13:24:58 2026, elog_producer, energy calibration, 23, ToF-iCT-Setup + DS LGAD + Ramon, 63.3 MeV/u, Low Flux High, Helium, Good, 17.01.2026 12:54:33, 17.01.2026 13:25:02, 30, Normal, None,
|
automatic log for run 23
Comment:
trigger window 85ns post, 1.915 us pre, 30mb/s events, 0.6mb/s drop, 2.5E+5 particle rate ramon, dogma 160kHz |
Sat Jan 17 12:53:45 2026, elog_producer, energy calibration, 22, ToF-iCT-Setup + DS LGAD + Ramon, 73.2 MeV/u, Low Flux High, Helium, Good, 17.01.2026 12:30:24, 17.01.2026 12:53:49, 23, Normal, None,
|
automatic log for run 22
Comment:
trigger window 85ns post, 1.915 us pre, 31mb/s events, 1mb/s drop, 1.8E+6 particle rate ramon, dogma 160kHz |
Sat Jan 17 12:29:24 2026, elog_producer, energy calibration, 21, ToF-iCT-Setup + DS LGAD + Ramon, 97.2MeV/u, Low Flux High, Helium, Good, 17.01.2026 12:21:43, 17.01.2026 12:29:27, 7, Normal, None,
|
automatic log for run 21
Comment:
trigger window 85ns post, 1.915 us pre, 51mb/s events, 6mb/s drop, 6.4E+6 particle rate ramon, dogma 160kHz |
Sun Jul 12 06:52:16 2026, elog_producer, Head Phantom, 21, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 200 MeV/u, Nominal, Mixed Beam (He+C), Unknown, 12.07.2026 02:20:25, 12.07.2026 06:52:17, 271, Normal, Head, 
|
automatic log for run 21
Comment:
Start automatet Spot measurements of head phantom
2:19: thr were not set correctly, no data at beginning of run 21
2:23: reset trigger window to 3us
runs 21-25 high statistics spots
ab run 81: 1mm Platte zusätzlich |
Sat Jan 17 12:20:18 2026, elog_producer, energy calibration, 20, ToF-iCT-Setup + DS LGAD + Ramon, 147.2 MeV/u, Low Flux High, Helium, Good, 17.01.2026 12:11:18, 17.01.2026 12:20:21, 9, Normal, None,
|
automatic log for run 20
Comment:
trigger window 85ns post, 1.915 us pre, 65mb/s events, 11mb/s drop, 8E+6 particle rate ramon, dogma 160kHz |
Sun Jul 12 01:12:43 2026, elog_producer, Slabs, 20, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 200 MeV/u, Nominal, Mixed Beam (He+C), Unknown, 12.07.2026 01:06:36, 12.07.2026 01:12:43, 6, Normal, RW3, 13 cm
|
automatic log for run 20
Comment:
He only |
Sun Jun 7 01:18:32 2026, elog_producer, GSI Sensor Test, 2, ToF-iCT-Setup + DS LGAD + Ramon, 800 MeV, Low Flux High, Proton, Unknown, 07.06.2026 00:37:15, 07.06.2026 01:18:44, 41, Normal, None,
|
automatic log for run 2
Comment: |
Sat Jul 11 17:35:21 2026, elog_producer, GSI Sensor Test, 2, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 800 MeV, Low Flux High, Proton, Unknown, 11.07.2026 17:24:28, 11.07.2026 17:35:21, 10, Normal, RW3,
|
automatic log for run 2
Comment:
In beam: 3 cm RW3 + PTW34070 Ionization Chamber + 11 cm RW3 + PTW34070 Ionization Chamber + 1 cm RW3
Testing DS LGAD/SIPM, trigger on DS
DS: thr 1000-200
SIPM thr scan, current limit: 300uA, saturated at 250 uA
thr:1000 |
Sat Jan 17 12:09:44 2026, elog_producer, energy calibration, 19, ToF-iCT-Setup + DS LGAD + Ramon, 177.8 MeV/u, Low Flux High, Helium, Good, 17.01.2026 12:01:45, 17.01.2026 12:09:48, 8, Normal, None,
|
automatic log for run 19
Comment:
trigger window 85ns post, 1.915 us pre, 81mb/s events, 40mb/s drop, 1.15E+7 particle rate ramon, dogma 160kHz |
Sun Jul 12 01:06:26 2026, elog_producer, Slabs, 19, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 200 MeV/u, Nominal, Mixed Beam (He+C), Unknown, 12.07.2026 00:55:52, 12.07.2026 01:06:26, 10, Normal, RW3, 13 cm
|
automatic log for run 19
Comment:
Carbon only |
Sat Jan 17 12:00:49 2026, elog_producer, energy calibration, 18, ToF-iCT-Setup + DS LGAD + Ramon, 205.2 MeV/u, Low Flux High, Helium, Good, 17.01.2026 11:52:18, 17.01.2026 12:00:53, 8, Normal, None,
|
automatic log for run 18
Comment:
trigger window 85ns post, 1.915 us pre, 84mb/s events, 50mb/s drop, 1.15E+7 particle rate ramon, dogma 160kHz |
Sun Jul 12 00:54:55 2026, elog_producer, Slabs, 18, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 200 MeV/u, Nominal, Mixed Beam (He+C), Unknown, 12.07.2026 00:41:46, 12.07.2026 00:54:56, 13, Normal, RW3, 13 cm
|
automatic log for run 18
Comment:
mixed beam
TDC died again (00:50)
TDC back again (00:53) |
Sat Jan 17 11:50:32 2026, elog_producer, alignment run, 17, ToF-iCT-Setup + DS LGAD + Ramon, 402MeV/u, Low Flux High, Helium, Good, 17.01.2026 11:39:20, 17.01.2026 11:50:35, 11, Normal, None,
|
automatic log for run 17
Comment:
trigger window 85ns post, 1.915 us pre, 87mb/s events, 77mb/s drop, 1.15E+7 particle rate ramon, dogma 160kHz |
Sun Jul 12 00:40:25 2026, elog_producer, Slabs, 17, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 200 MeV/u, Nominal, Mixed Beam (He+C), Unknown, 12.07.2026 00:23:03, 12.07.2026 00:40:26, 17, Normal, RW3, 15 cm
|
automatic log for run 17
Comment:
Carbon only |
Sun Jun 7 11:09:39 2026, Harald Handerkas, Phantom iCT runs log entries, 16-295, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 06:49:15, 07.06.2026 11:06:55, 257, Normal, Cylinder with inserts, 
|
| Run settings and log file for runs |
Sat Jan 17 11:37:32 2026, elog_producer, alignment run, 16, ToF-iCT-Setup + DS LGAD + Ramon, 402MeV/u, Low Flux High, Helium, Good, 17.01.2026 11:34:37, 17.01.2026 11:37:36, 2, Normal, None,
|
automatic log for run 16
Comment:
trigger window 85ns post, 2.915 us pre, 95mb/s events, 100mb/s drop, 1.15E+7 particle rate ramon, dogma 160kHz |
Sun Jun 7 11:06:43 2026, elog_producer, Phantom Testrun without DAQ, 16, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 06:49:15, 07.06.2026 11:06:55, 257, Normal, None,
|
automatic log for run 16
Comment:
iCT tomographie runs |
Sun Jul 12 00:22:16 2026, elog_producer, Slabs, 16, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 200 MeV/u, Nominal, Mixed Beam (He+C), Unknown, 12.07.2026 00:06:28, 12.07.2026 00:22:16, 15, Normal, RW3, 15 cm
|
automatic log for run 16
Comment:
Helium only
lost one TDC (00:09)
back again (00:18) |
Sat Jan 17 11:33:33 2026, elog_producer, Rate Test, 15, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Low, Helium, Good, 17.01.2026 11:31:19, 17.01.2026 11:33:37, 2, Normal, None,
|
automatic log for run 15
Comment:
trigger window 85ns post, 2.915 us pre, 25kb/s events, 0mb/s drop, 6E+3 particle rate ramon |
Sun Jun 7 06:48:30 2026, elog_producer, Phantom Testrun without DAQ, 15, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 06:43:51, 07.06.2026 06:48:42, 4, Normal, None,
|
automatic log for run 15
Comment: |
|