Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025 testbeam-MA2026
  Testbeams at MedAustron in 2026, Page 3 of 3  Not logged in ELOG logo
ID Date Author Subjectdown Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  6   Sat Jan 17 10:40:24 2026 elog_producerRate Test8ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 10:31:1217.01.2026 10:40:289NormalNone 
automatic log for run 8
Comment:
trigger window: 85ns post, 1.915 us pre
  7   Sat Jan 17 10:48:31 2026 elog_producerRate Test9ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumGood17.01.2026 10:42:2317.01.2026 10:48:356NormalNone 
automatic log for run 9
Comment:
trigger window 85 ns post, 1.915 us pre, 70mb/s events, 15mb/s drop
  8   Sat Jan 17 10:55:49 2026 elog_producerRate Test10ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumGood17.01.2026 10:51:1517.01.2026 10:55:534NormalNone 
automatic log for run 10
Comment:
trigger window 85 ns post, 640 ns pre, 52mb/s events, 4mb/s drop, 9E+6 particle rate ramon
  9   Sat Jan 17 11:00:50 2026 elog_producerRate Test11ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumGood17.01.2026 10:57:2217.01.2026 11:00:543NormalNone 
automatic log for run 11
Comment:
trigger window 85ns post, 2.915 us pre, 80mb/s events, 25mb/s drop, 9E+6 particle rate ramon
  10   Sat Jan 17 11:06:15 2026 elog_producerRate Test12ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumGood17.01.2026 11:02:0117.01.2026 11:06:194NormalNone 
automatic log for run 12
Comment:
trigger window 85ns post, 3.915 us pre, 100mb/s events, 40mb/s drop, 9E+6 particle rate ramon
  11   Sat Jan 17 11:13:44 2026 elog_producerRate Test13ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 11:06:5117.01.2026 11:13:486NormalNone 
automatic log for run 13
Comment:
trigger window 85ns post, 3.915 us pre, 33mb/s events, 1mb/s drop, 4E+6 particle rate ramon
  12   Sat Jan 17 11:30:05 2026 elog_producerRate Test14ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 11:14:4617.01.2026 11:30:0915NormalNone 
automatic log for run 14
Comment:
trigger window 85ns post, 2.915 us pre, 30mb/s events, 0.6mb/s drop, 4E+6 particle rate ramon
  13   Sat Jan 17 11:33:33 2026 elog_producerRate Test15ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux LowHeliumGood17.01.2026 11:31:1917.01.2026 11:33:372NormalNone 
automatic log for run 15
Comment:
trigger window 85ns post, 2.915 us pre, 25kb/s events, 0mb/s drop, 6E+3 particle rate ramon
  3   Sat Jan 17 09:49:36 2026 elog_producerAlignment4ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumUnknown17.01.2026 09:47:5217.01.2026 09:49:401NormalNone 
automatic log for run 4
Comment:
Alignment

wrong energy, 402.8!
  4   Sat Jan 17 10:03:40 2026 elog_producerAlignment5ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 09:49:5117.01.2026 10:03:4413NormalNone 
automatic log for run 5
Comment:
Alignment + system test
ELOG V3.1.5-fc6679b