Entry  Sat Jan 17 11:06:15 2026, elog_producer, Rate Test, 12, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Good, 17.01.2026 11:02:01, 17.01.2026 11:06:19, 4, Normal, None,  ramon.conf
automatic log for run 12
Comment:
trigger window 85ns post, 3.915 us pre, 100mb/s events, 40mb/s drop, 9E+6 particle rate ramon
Entry  Sat Jan 17 11:00:50 2026, elog_producer, Rate Test, 11, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Good, 17.01.2026 10:57:22, 17.01.2026 11:00:54, 3, Normal, None,  ramon.conf
automatic log for run 11
Comment:
trigger window 85ns post, 2.915 us pre, 80mb/s events, 25mb/s drop, 9E+6 particle rate ramon
Entry  Sat Jan 17 10:55:49 2026, elog_producer, Rate Test, 10, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Good, 17.01.2026 10:51:15, 17.01.2026 10:55:53, 4, Normal, None,  ramon.conf
automatic log for run 10
Comment:
trigger window 65 ns post, 640 ns pre, 52mb/s events, 4mb/s drop, 9E+6 particle rate ramon
Entry  Sat Jan 17 10:48:31 2026, elog_producer, Rate Test, 9, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Good, 17.01.2026 10:42:23, 17.01.2026 10:48:35, 6, Normal, None,  ramon.conf
automatic log for run 9
Comment:
trigger window 85 ns post, 1.915 us pre, 70mb/s events, 15mb/s drop
Entry  Sat Jan 17 10:40:24 2026, elog_producer, Rate Test, 8, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Good, 17.01.2026 10:31:12, 17.01.2026 10:40:28, 9, Normal, None,  ramon.conf
automatic log for run 8
Comment:
trigger window: 58ns post, 1.915 us pre
Entry  Sat Jan 17 10:28:47 2026, elog_producer, Rate Test, 7, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Good, 17.01.2026 10:08:42, 17.01.2026 10:28:51, 20, Normal, None,  ramon.conf
automatic log for run 7
Comment:
rate test
Entry  Sat Jan 17 10:03:40 2026, elog_producer, Alignment, 5, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Good, 17.01.2026 09:49:51, 17.01.2026 10:03:44, 13, Normal, None,  ramon.conf
automatic log for run 5
Comment:
Alignment + system test
Entry  Sat Jan 17 09:49:36 2026, elog_producer, Alignment, 4, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Unknown, 17.01.2026 09:47:52, 17.01.2026 09:49:40, 1, Normal, None,  ramon.conf
automatic log for run 4
Comment:
Alignment

wrong energy, 402.8!
Entry  Sat Jan 17 09:47:28 2026, elog_producer, Test, 1, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Unknown, 17.01.2026 09:35:36, 17.01.2026 09:47:31, 11, Normal, None,  ramon.conf
automatic log for run 1
Comment:
System Test till run 3
Entry  Sat Jan 17 09:35:25 2026, elog_producer, Test, 0, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Nominal, Helium, Unknown, 17.01.2026 08:29:29, 17.01.2026 09:35:28, 65, Normal, None,  ramon.conf
automatic log for run 0
Comment:
System Test