ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness Text Attachments
  46   Sat Jan 17 20:06:29 2026 elog_producersensor test51ToF-iCT-Setup + DS LGAD + Ramon800 MeVLow Flux HighProtonGood17.01.2026 20:01:2017.01.2026 20:06:335NormalNone automatic log for run 51
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  45   Sat Jan 17 19:48:15 2026 elog_producersensor test50ToF-iCT-Setup + DS LGAD + Ramon800 MeVLow Flux HighProtonGood17.01.2026 19:45:3217.01.2026 19:48:192NormalNone automatic log for run 50
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  44   Sat Jan 17 19:32:19 2026 elog_producersensor test49ToF-iCT-Setup + DS LGAD + Ramon800 MeVLow Flux HighProtonGood17.01.2026 19:14:0017.01.2026 19:32:2318NormalNone automatic log for run 49
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  43   Sat Jan 17 18:48:53 2026 elog_producerradiographie48ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 18:44:2517.01.2026 18:48:574NormalNone automatic log for run 48
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  42   Sat Jan 17 18:43:38 2026 elog_producerradiographie47ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 18:39:2017.01.2026 18:43:434NormalNone automatic log for run 47
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  41   Sat Jan 17 18:38:43 2026 elog_producerradiographie46ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 18:34:5817.01.2026 18:38:473NormalNone automatic log for run 46
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  40   Sat Jan 17 18:34:21 2026 elog_producerradiographie45ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 18:31:0117.01.2026 18:34:243NormalNone automatic log for run 45
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  39   Sat Jan 17 18:30:20 2026 elog_producerradiographie44ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 18:27:1717.01.2026 18:30:243NormalNone automatic log for run 44
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  38   Sat Jan 17 18:26:28 2026 elog_producerradiographie43ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 18:22:3917.01.2026 18:26:323NormalNone automatic log for run 43
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  37   Sat Jan 17 18:21:57 2026 elog_producerradiographie42ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 18:17:4617.01.2026 18:22:014NormalNone automatic log for run 42
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  36   Sat Jan 17 18:14:19 2026 elog_producerradiographie41ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 18:10:0017.01.2026 18:14:234NormalNone automatic log for run 41
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  35   Sat Jan 17 18:09:21 2026 elog_producerradiographie40ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 18:05:0517.01.2026 18:09:254NormalNone automatic log for run 40
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  34   Sat Jan 17 18:04:23 2026 elog_producerradiographie39ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 17:57:5017.01.2026 18:04:276NormalNone automatic log for run 39
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  33   Sat Jan 17 17:57:07 2026 elog_producerradiographie38ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 17:51:1817.01.2026 17:57:115NormalNone automatic log for run 38
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  32   Sat Jan 17 17:50:08 2026 elog_producerradiographie37ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 17:43:0217.01.2026 17:50:127NormalNone automatic log for run 37
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  31   Sat Jan 17 17:34:20 2026 elog_producerradiographie36ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumGood17.01.2026 17:29:1317.01.2026 17:34:235NormalNone automatic log for run 36
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  30   Sat Jan 17 16:43:52 2026 elog_producerradiographie35ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumGood17.01.2026 16:38:5717.01.2026 16:43:564NormalNone automatic log for run 35
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  29   Sat Jan 17 16:37:36 2026 elog_producerradiographie34ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumGood17.01.2026 16:32:4417.01.2026 16:37:404NormalNone automatic log for run 34
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  28   Sat Jan 17 16:32:13 2026 elog_producerradiographie33ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumGood17.01.2026 16:28:4917.01.2026 16:32:163NormalNone automatic log for run 33
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
  27   Sat Jan 17 16:27:50 2026 elog_producerradiographie32ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumGood17.01.2026 16:24:0417.01.2026 16:27:533NormalNone automatic log for run 32
Comment:
trigger window  85ns post, 1.915 us pre,
 ramon.conf 
ELOG V3.1.5-fc6679b