Sat Jan 17 10:40:24 2026, elog_producer, Rate Test, 8, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Good, 17.01.2026 10:31:12, 17.01.2026 10:40:28, 9, Normal, None,
|
automatic log for run 8
Comment:
trigger window: 85ns post, 1.915 us pre |
Sat Jan 17 12:20:18 2026, elog_producer, energy calibration, 20, ToF-iCT-Setup + DS LGAD + Ramon, 147.2 MeV/u, Low Flux High, Helium, Good, 17.01.2026 12:11:18, 17.01.2026 12:20:21, 9, Normal, None,
|
automatic log for run 20
Comment:
trigger window 85ns post, 1.915 us pre, 65mb/s events, 11mb/s drop, 8E+6 particle rate ramon, dogma 160kHz |
Sun Jun 7 04:57:46 2026, elog_producer, Energy Calibration, 10, ToF-iCT-Setup + DS LGAD + Ramon, 147.2 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 04:48:57, 07.06.2026 04:57:58, 9, Normal, None,
|
automatic log for run 10
Comment: |
Sun Jun 7 13:23:15 2026, elog_producer, Sandwich ToF calibration, 304, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 13:14:24, 07.06.2026 13:23:27, 9, Normal, Dense Bone Slabs, 1 cm
|
automatic log for run 304
Comment:
Bone Plate 1 cm |
Sun Jun 7 13:57:40 2026, elog_producer, Sandwich ToF calibration, 307, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 13:48:48, 07.06.2026 13:57:52, 9, Normal, bone+lung, 2 cm
|
automatic log for run 307
Comment:
first 1cm lung, then 1 cm bone (in beam direction) |
Sat Jul 11 16:26:54 2026, elog_producer, GSI Sensor Test, 1, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 800 MeV, Low Flux High, Proton, Unknown, 11.07.2026 16:17:29, 11.07.2026 16:26:54, 9, Normal, RW3,
|
automatic log for run 1
Comment:
In beam: 3 cm RW3 + PTW34070 Ionization Chamber + 11 cm RW3 + PTW34070 Ionization Chamber + 1 cm RW3
|
Sun Jun 7 02:41:32 2026, elog_producer, GSI Sensor Test, 3, ToF-iCT-Setup + DS LGAD + Ramon, 800 MeV, Low Flux High, Proton, Unknown, 07.06.2026 01:19:47, 07.06.2026 02:41:43, 81, Normal, None,
|
automatic log for run 3
Comment:
Trigger on last detector |
Sat Jan 17 12:00:49 2026, elog_producer, energy calibration, 18, ToF-iCT-Setup + DS LGAD + Ramon, 205.2 MeV/u, Low Flux High, Helium, Good, 17.01.2026 11:52:18, 17.01.2026 12:00:53, 8, Normal, None,
|
automatic log for run 18
Comment:
trigger window 85ns post, 1.915 us pre, 84mb/s events, 50mb/s drop, 1.15E+7 particle rate ramon, dogma 160kHz |
Sat Jan 17 12:09:44 2026, elog_producer, energy calibration, 19, ToF-iCT-Setup + DS LGAD + Ramon, 177.8 MeV/u, Low Flux High, Helium, Good, 17.01.2026 12:01:45, 17.01.2026 12:09:48, 8, Normal, None,
|
automatic log for run 19
Comment:
trigger window 85ns post, 1.915 us pre, 81mb/s events, 40mb/s drop, 1.15E+7 particle rate ramon, dogma 160kHz |
Sun Jun 7 13:08:43 2026, elog_producer, Sandwich ToF calibration, 303, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 13:00:37, 07.06.2026 13:08:55, 8, Normal, RW3 Plate, 2.5 cm
|
automatic log for run 303
Comment:
RW Plate 2.5 cm |
Sat Jul 11 21:13:28 2026, elog_producer, Energy calibration, 7, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 402MeV/u, Low Flux High, Helium, Unknown, 11.07.2026 21:04:44, 11.07.2026 21:13:29, 8, Normal, None,
|
automatic log for run 7
Comment: |
Sat Jan 17 12:29:24 2026, elog_producer, energy calibration, 21, ToF-iCT-Setup + DS LGAD + Ramon, 97.2MeV/u, Low Flux High, Helium, Good, 17.01.2026 12:21:43, 17.01.2026 12:29:27, 7, Normal, None,
|
automatic log for run 21
Comment:
trigger window 85ns post, 1.915 us pre, 51mb/s events, 6mb/s drop, 6.4E+6 particle rate ramon, dogma 160kHz |
Sat Jan 17 17:50:08 2026, elog_producer, radiographie, 37, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Good, 17.01.2026 17:43:02, 17.01.2026 17:50:12, 7, Normal, None,
|
automatic log for run 37
Comment:
trigger window 85ns post, 1.915 us pre, 999mb/s events, 999mb/s drop, 5E+6 particle rate ramon, dogma 160kHz, x=0, y=-2, forsetzung von run036 |
Sun Jun 7 12:15:21 2026, elog_producer, Sandwich ToF calibration, 299, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 12:08:02, 07.06.2026 12:15:33, 7, Normal, RW3 Plate, 4 cm
|
automatic log for run 299
Comment:
RW Plate 4 cm |
Sun Jun 7 12:28:00 2026, elog_producer, Sandwich ToF calibration, 300, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 12:21:05, 07.06.2026 12:28:13, 7, Normal, RW3 Plate, 1 mm
|
automatic log for run 300
Comment:
RW Plate 1 mm |
Sun Jun 7 13:44:55 2026, elog_producer, Sandwich ToF calibration, 306, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Unknown, 07.06.2026 13:37:47, 07.06.2026 13:45:07, 7, Normal, bone+lung, 2 cm
|
automatic log for run 306
Comment:
first 1 cm bone, then 1cm lung (in beam direction) |
Sat Jul 11 20:53:37 2026, elog_producer, He Alignment + mixed beam verification, 6, TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup, 402MeV/u, Low Flux High, Helium, Unknown, 11.07.2026 19:45:15, 11.07.2026 20:53:38, 68, Normal, None,
|
automatic log for run 6
Comment:
ohne empty bucket
|
Sat Jan 17 09:35:25 2026, elog_producer, Test, 0, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Nominal, Helium, Unknown, 17.01.2026 08:29:29, 17.01.2026 09:35:28, 65, Normal, None,
|
automatic log for run 0
Comment:
System Test |
Sat Jan 17 10:48:31 2026, elog_producer, Rate Test, 9, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux High, Helium, Good, 17.01.2026 10:42:23, 17.01.2026 10:48:35, 6, Normal, None,
|
automatic log for run 9
Comment:
trigger window 85 ns post, 1.915 us pre, 70mb/s events, 15mb/s drop |
Sat Jan 17 11:13:44 2026, elog_producer, Rate Test, 13, ToF-iCT-Setup + DS LGAD + Ramon, 124.4 MeV/u, Low Flux Medium, Helium, Good, 17.01.2026 11:06:51, 17.01.2026 11:13:48, 6, Normal, None,
|
automatic log for run 13
Comment:
trigger window 85ns post, 3.915 us pre, 33mb/s events, 1mb/s drop, 4E+6 particle rate ramon |
|