Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025 testbeam-MA2026
  Testbeams at MedAustron in 2026, Page 1 of 6  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Datadown t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  1   Sat Jan 17 09:35:25 2026 elog_producerTest0ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uNominalHeliumUnknown17.01.2026 08:29:2917.01.2026 09:35:2865NormalNone 
automatic log for run 0
Comment:
System Test
  2   Sat Jan 17 09:47:28 2026 elog_producerTest1ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumUnknown17.01.2026 09:35:3617.01.2026 09:47:3111NormalNone 
automatic log for run 1
Comment:
System Test till run 3
  3   Sat Jan 17 09:49:36 2026 elog_producerAlignment4ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux MediumHeliumUnknown17.01.2026 09:47:5217.01.2026 09:49:401NormalNone 
automatic log for run 4
Comment:
Alignment

wrong energy, 402.8!
  51   Sun Jun 7 00:30:29 2026 elog_producerTest DAQ1ToF-iCT-Setup + DS LGAD + Ramon402MeV/uLow Flux HighHeliumUnknown07.06.2026 00:19:4307.06.2026 00:30:4110NormalNone 
automatic log for run 1
Comment:
402.8 MeV/u
Aufnahme: 150kHz
Schreiben: 250Mbyte/s
  52   Sun Jun 7 01:18:32 2026 elog_producerGSI Sensor Test2ToF-iCT-Setup + DS LGAD + Ramon800 MeVLow Flux HighProtonUnknown07.06.2026 00:37:1507.06.2026 01:18:4441NormalNone 
automatic log for run 2
Comment:
  53   Sun Jun 7 02:41:32 2026 elog_producerGSI Sensor Test3ToF-iCT-Setup + DS LGAD + Ramon800 MeVLow Flux HighProtonUnknown07.06.2026 01:19:4707.06.2026 02:41:4381NormalNone 
automatic log for run 3
Comment:
Trigger on last detector
  54   Sun Jun 7 03:20:58 2026 elog_producerAlignment He4ToF-iCT-Setup + DS LGAD + Ramon402MeV/uLow Flux HighHeliumUnknown07.06.2026 02:59:5507.06.2026 03:21:1021NormalNone 
automatic log for run 4
Comment:
Alignment run
70 MB/s / eb
  55   Sun Jun 7 03:44:28 2026 elog_producerRate Test5ToF-iCT-Setup + DS LGAD + Ramon402MeV/uLow Flux HighHeliumUnknown07.06.2026 03:23:4907.06.2026 03:44:4020NormalNone 
automatic log for run 5
Comment:
3 us trigger window
110 mb/s /eb
rejected: 70 mb/s
  56   Sun Jun 7 04:04:12 2026 elog_producerRate Test6ToF-iCT-Setup + DS LGAD + Ramon402MeV/uLow Flux HighHeliumUnknown07.06.2026 03:52:4807.06.2026 04:04:2411NormalNone 
automatic log for run 6
Comment:
new threshold scan

trigger window: 200 ns
threshold at 1500
  57   Sun Jun 7 04:22:48 2026 elog_producerEnergy Calibration7ToF-iCT-Setup + DS LGAD + Ramon205.2 MeV/uLow Flux HighHeliumUnknown07.06.2026 04:06:0907.06.2026 04:23:0016NormalNone 
automatic log for run 7
Comment:
  58   Sun Jun 7 04:46:11 2026 elog_producerEnergy Calibration9ToF-iCT-Setup + DS LGAD + Ramon177.8 MeV/uLow Flux HighHeliumUnknown07.06.2026 04:33:5707.06.2026 04:46:2312NormalNone 
automatic log for run 9
Comment:
  59   Sun Jun 7 04:56:18 2026 Harald HanderkasEnergy Calibration8ToF-iCT-Setup + DS LGAD + Ramon205.2 MeV/uLow Flux HighHeliumUnknown   NormalNone 
Comment:
threshold 2500
  60   Sun Jun 7 04:57:46 2026 elog_producerEnergy Calibration10ToF-iCT-Setup + DS LGAD + Ramon147.2 MeV/uLow Flux HighHeliumUnknown07.06.2026 04:48:5707.06.2026 04:57:589NormalNone 
automatic log for run 10
Comment:
  61   Sun Jun 7 05:13:06 2026 elog_producerEnergy Calibration11ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumUnknown07.06.2026 04:58:3907.06.2026 05:13:1814NormalNone 
automatic log for run 11
Comment:
  62   Sun Jun 7 05:28:09 2026 elog_producerEnergy Calibration12ToF-iCT-Setup + DS LGAD + Ramon97.2MeV/uLow Flux HighHeliumUnknown07.06.2026 05:13:5307.06.2026 05:28:2214NormalNone 
automatic log for run 12
Comment:
eventbuilder eb 811 last files contain run 13 -> delete last files (eb was started 2x with wrong xml)
  63   Sun Jun 7 05:48:23 2026 elog_producerEnergy Calibration13ToF-iCT-Setup + DS LGAD + Ramon73.2 MeV/uLow Flux HighHeliumUnknown07.06.2026 05:29:3907.06.2026 05:48:3518NormalNone 
automatic log for run 13
Comment:
  64   Sun Jun 7 06:09:04 2026 elog_producerEnergy Calibration14ToF-iCT-Setup + DS LGAD + Ramon63.3 MeV/uLow Flux HighHeliumUnknown07.06.2026 05:49:1707.06.2026 06:09:1719NormalNone 
automatic log for run 14
Comment:
  65   Sun Jun 7 06:48:30 2026 elog_producerPhantom Testrun without DAQ15ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumUnknown07.06.2026 06:43:5107.06.2026 06:48:424NormalNone 
automatic log for run 15
Comment:
  66   Sun Jun 7 11:06:43 2026 elog_producerPhantom Testrun without DAQ16ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumUnknown07.06.2026 06:49:1507.06.2026 11:06:55257NormalNone 
automatic log for run 16
Comment:
iCT tomographie runs
  67   Sun Jun 7 11:09:39 2026 Harald HanderkasPhantom iCT runs log entries16-295ToF-iCT-Setup + DS LGAD + Ramon124.4 MeV/uLow Flux HighHeliumUnknown07.06.2026 06:49:1507.06.2026 11:06:55257NormalCylinder with inserts 
Run settings and log file for runs
ELOG V3.1.5-fc6679b