Message ID: 85     Entry time: Sat Jul 11 19:34:51 2026
Author: elog_producer 
Subject: Rate Test 
Run Number:
DUT: TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup 
Beam Energy: 200 MeV/u 
Rate Setting: Nominal 
Particle Type: Mixed Beam (He+C) 
Data: Unknown 
t-Start: 11.07.2026 19:01:26 
t-Stop: 11.07.2026 19:34:51 
Duration_min: 33 
Frontend: Normal 
Phantom: RW3 
Phantom thickness:  
automatic log for run 5
Comment:
In beam: 3 cm RW3 + PTW34070 Ionization Chamber + 11 cm RW3 + PTW34070 Ionization Chamber + 1 cm RW3

trigger on plane 4
use max rate settings (nominal with 10% He) of mixed beam
rate per strip: 60-90khz for front detector
about MHz per detector
data written: 12MB/s per eb
absolut: 50 MB/s leading