Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
|
|
testbeam-MA2018
testbeam-MA2019
testbeam-MA2020
testbeam-MA2021
testbeam-MA2023
testbeam-MA2024
testbeam-MA2025
testbeam-MA2026
|
| Testbeams at MedAustron in 2026 |
Not logged in |
 |
|
|
Message ID: 85
Entry time: Sat Jul 11 19:34:51 2026
|
| Author: |
elog_producer |
| Subject: |
Rate Test |
| Run Number: |
5 |
| DUT: |
TOF-Cal_GSI_8LGAD+RaMon+SIPM-Setup |
| Beam Energy: |
200 MeV/u |
| Rate Setting: |
Nominal |
| Particle Type: |
Mixed Beam (He+C) |
| Data: |
Unknown |
| t-Start: |
11.07.2026 19:01:26 |
| t-Stop: |
11.07.2026 19:34:51 |
| Duration_min: |
33 |
| Frontend: |
Normal |
| Phantom: |
RW3 |
| Phantom thickness: |
|
|
|
automatic log for run 5
Comment:
In beam: 3 cm RW3 + PTW34070 Ionization Chamber + 11 cm RW3 + PTW34070 Ionization Chamber + 1 cm RW3
trigger on plane 4
use max rate settings (nominal with 10% He) of mixed beam
rate per strip: 60-90khz for front detector
about MHz per detector
data written: 12MB/s per eb
absolut: 50 MB/s leading |
|