Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 9 of 13  Not logged in ELOG logo
ID Date Author Subjectdown Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  241   Sat Sep 20 21:00:14 2025 elog_producerCaribou 1.5 RD50-MPW4800 MeVLow Flux HighProtonUnknown   Normal  
changing Peary readout to DMA
  242   Sat Sep 20 21:00:20 2025 elog_producerCaribou 1.5 RD50-MPW4800 MeVLow Flux HighProtonUnknown   Normal  
changing Peary readout to DMA
  243   Sat Sep 20 21:02:14 2025 elog_producerCaribou 1.51041RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:01:3420.09.2025 21:02:260Normal  
automatic log for run 1041
Comment:
no data from DMA Frown
  244   Sat Sep 20 21:12:30 2025 elog_producerCaribou 1.51042RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:11:5720.09.2025 21:12:410Normal  
automatic log for run 1042
Comment:
DMA debugging
  245   Sat Sep 20 21:19:04 2025 elog_producerCaribou 1.5 RD50-MPW4800 MeVLow Flux HighProtonUnknown   Normal  
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
  246   Sat Sep 20 21:19:29 2025 elog_producerCaribou 1.51043RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:18:0920.09.2025 21:19:401Normal  
automatic log for run 1043
Comment:
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
  247   Sat Sep 20 21:23:52 2025 elog_producerCaribou 1.51044RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:23:4420.09.2025 21:24:030Normal  
automatic log for run 1044
Comment:
DMA debugging
no data
  197   Sat Aug 16 23:44:00 2025 Maximilian BabelukCASTID - Summary TJ-Monopix2800 MeV Proton       

Summary for the CASTID shift RO Aug 16, 2025

We measured four TJ-Monopix2 DUTS with HV/HVC frontends using AIDA mode in a stacked telescope configuration. We used 800MeV protons at low flux settings from very low to high.

 

We took two high statistics runs on each of the 4 rates. Then we repeated the measurements at medium and high settings for following readout speeds (40 is the default): 30, 20, 10, 2 (minimum).

At increased readout speed, we shoudl be able to recover (part) of the efficiency drop at increased rates.

- Occasionally (maybe a few times an hour but in clusters) we got 8b/10b errors. If so, they all came from the W02R01 DUT using BDAQ board #063/50 and the TLU adapter 1. This is the main source of having 'crap' data

- About 3 times during the test beam, one of the chips (each time a different one) stopped sending data which was possible to recover with a power cycle.

 

  61   Sat Mar 15 08:52:52 2025 RD50 Generic UserAlignment Run 800MeV2Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux MediumProtonGood08:229:4078   

RaMon Rate 400kHz

front sensors 200mu: ~10-20kHz pro Streifen

Comments:

In between run, sensors were shifted by 2mm to the left (left and right in online DAQ is mirrored)

 

  62   Sat Mar 15 08:58:26 2025 RD50 Generic UserAlignment Run 800MeV1Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux LowProtonGood07:4008:2040   

RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro Streifen

Comments:

stopped run due to too low rate

 

  63   Sat Mar 15 09:51:23 2025 RD50 Generic UserAlignment Run 800MeV3Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux HighProtonUnknown9:4410:0319   

RaMon Rate 2MHz

front sensors 200mu: ~50-100kHz pro Streifen

Comments:

Factor 10 lost more data than measured

 

  64   Sat Mar 15 10:07:28 2025 RD50 Generic UserAlignment Run 252MeV4Sandwich-iCT setup(GSI)+RaMon252.7 MeVLow Flux MediumProtonGood10:0711:4396   

RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen

  78   Sat Jun 21 17:01:05 2025 Julia Müllner97.2 MeV systemtest 4TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood16:5817:1113   

Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12.

  79   Sat Jun 21 17:13:34 2025 Julia Müllner97.2 MeV systemtest 5TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood17:3117:5423   

Threshold set to 3000

moved Ripple filters back in 

100GB data collected

  80   Sat Jun 21 17:54:27 2025 Julia Müllner97.2 MeV systemtest 6TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood17:5618:048   

Threshold set to 4000

40GB data collected

  81   Sat Jun 21 18:05:21 2025 Julia Müllner97.2 MeV systemtest 7TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood18:0618:2115   

Threshold set to 2000

50GB data collected

Room Entry Request: 18:21

  75   Sat Jun 21 14:30:29 2025 Julia Müllner800MeV systemtest 1TOF-Cal GSI800 MeVLow Flux HighProtonGood14:4515:4257   

first spills were done with low flux medium, changed to high at 14:49

again changed to medium at 14:55

again changed to high at 15:00

30 MB pro event builder

last few spills were with the wrong threshold

thresholds were set to 2000 instead of 1000 

  76   Sat Jun 21 15:43:47 2025 Julia Müllner800MeV systemtest 2TOF-Cal GSI800 MeVLow Flux HighProtonGood16:0216:2927   

Threshold set to 1000

Factor 4 chosen for future runs, 80 GB in total recorded in this run

  82   Sat Jun 21 18:22:28 2025 Julia Müllner73.2 MeV systemtest 8TOF-Cal GSI73.2 MeV/uLow Flux HighHeliumCrap19:1019:2111   

new callibration was done, dimanond detector connected to readout

Threshold = 4000

thresholds were too low -> run was canceled

  83   Sat Jun 21 19:22:45 2025 Julia Müllner73.2 MeV systemtest 9TOF-Cal GSI73.2 MeV/uLow Flux HighHeliumGood19:2319:3512   

Threshold change from 50 to 500

10GB collected

ELOG V3.1.5-fc6679b