Sat Sep 20 21:00:14 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,
|
changing Peary readout to DMA |
Sat Sep 20 21:00:20 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,
|
changing Peary readout to DMA |
Sat Sep 20 21:02:14 2025, elog_producer, Caribou 1.5, 1041, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:01:34, 20.09.2025 21:02:26, 0, Normal, ,  
|
automatic log for run 1041
Comment:
no data from DMA  |
Sat Sep 20 21:12:30 2025, elog_producer, Caribou 1.5, 1042, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:11:57, 20.09.2025 21:12:41, 0, Normal, ,  
|
automatic log for run 1042
Comment:
DMA debugging |
Sat Sep 20 21:19:04 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,
|
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now |
Sat Sep 20 21:19:29 2025, elog_producer, Caribou 1.5, 1043, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:18:09, 20.09.2025 21:19:40, 1, Normal, ,  
|
automatic log for run 1043
Comment:
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now |
Sat Sep 20 21:23:52 2025, elog_producer, Caribou 1.5, 1044, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:23:44, 20.09.2025 21:24:03, 0, Normal, ,  
|
automatic log for run 1044
Comment:
DMA debugging
no data |
Sat Aug 16 23:44:00 2025, Maximilian Babeluk, CASTID - Summary, , TJ-Monopix2, 800 MeV, , Proton, , , , , , ,
|
Summary for the CASTID shift RO Aug 16, 2025
We measured four TJ-Monopix2 DUTS with HV/HVC frontends using AIDA mode in a stacked telescope configuration. We used 800MeV protons at low flux settings from very low to high.
We took two high statistics runs on each of the 4 rates. Then we repeated the measurements at medium and high settings for following readout speeds (40 is the default): 30, 20, 10, 2 (minimum).
At increased readout speed, we shoudl be able to recover (part) of the efficiency drop at increased rates.
- Occasionally (maybe a few times an hour but in clusters) we got 8b/10b errors. If so, they all came from the W02R01 DUT using BDAQ board #063/50 and the TLU adapter 1. This is the main source of having 'crap' data
- About 3 times during the test beam, one of the chips (each time a different one) stopped sending data which was possible to recover with a power cycle.
|
Sat Mar 15 08:52:52 2025, RD50 Generic User, Alignment Run 800MeV, 2, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Medium, Proton, Good, 08:22, 9:40, 78, , ,
|
RaMon Rate 400kHz
front sensors 200mu: ~10-20kHz pro Streifen
Comments:
In between run, sensors were shifted by 2mm to the left (left and right in online DAQ is mirrored)
|
Sat Mar 15 08:58:26 2025, RD50 Generic User, Alignment Run 800MeV, 1, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Low, Proton, Good, 07:40, 08:20, 40, , ,
|
RaMon Rate not measured
front sensors 200mu: ~40-60Hz pro Streifen
Comments:
stopped run due to too low rate
|
Sat Mar 15 09:51:23 2025, RD50 Generic User, Alignment Run 800MeV, 3, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux High, Proton, Unknown, 9:44, 10:03, 19, , ,
|
RaMon Rate 2MHz
front sensors 200mu: ~50-100kHz pro Streifen
Comments:
Factor 10 lost more data than measured
|
Sat Mar 15 10:07:28 2025, RD50 Generic User, Alignment Run 252MeV, 4, Sandwich-iCT setup(GSI)+RaMon, 252.7 MeV, Low Flux Medium, Proton, Good, 10:07, 11:43, 96, , ,
|
RaMon Rate 1MHz
front sensors 200mu: ~10-25kHz pro Streifen |
Sat Jun 21 17:01:05 2025, Julia Müllner, 97.2 MeV systemtest , 4, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 16:58, 17:11, 13, , ,
|
Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12. |
Sat Jun 21 17:13:34 2025, Julia Müllner, 97.2 MeV systemtest , 5, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:31, 17:54, 23, , ,
|
Threshold set to 3000
moved Ripple filters back in
100GB data collected |
Sat Jun 21 17:54:27 2025, Julia Müllner, 97.2 MeV systemtest , 6, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:56, 18:04, 8, , ,
|
Threshold set to 4000
40GB data collected |
Sat Jun 21 18:05:21 2025, Julia Müllner, 97.2 MeV systemtest , 7, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 18:06, 18:21, 15, , ,
|
Threshold set to 2000
50GB data collected
Room Entry Request: 18:21 |
Sat Jun 21 14:30:29 2025, Julia Müllner, 800MeV systemtest , 1, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 14:45, 15:42, 57, , ,
|
first spills were done with low flux medium, changed to high at 14:49
again changed to medium at 14:55
again changed to high at 15:00
30 MB pro event builder
last few spills were with the wrong threshold
thresholds were set to 2000 instead of 1000 |
Sat Jun 21 15:43:47 2025, Julia Müllner, 800MeV systemtest , 2, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 16:02, 16:29, 27, , ,
|
Threshold set to 1000
Factor 4 chosen for future runs, 80 GB in total recorded in this run |
Sat Jun 21 18:22:28 2025, Julia Müllner, 73.2 MeV systemtest , 8, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Crap, 19:10, 19:21, 11, , ,
|
new callibration was done, dimanond detector connected to readout
Threshold = 4000
thresholds were too low -> run was canceled |
Sat Jun 21 19:22:45 2025, Julia Müllner, 73.2 MeV systemtest , 9, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Good, 19:23, 19:35, 12, , ,
|
Threshold change from 50 to 500
10GB collected |
|