Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 8 of 19  Not logged in ELOG logo
Entry  Sun Dec 7 01:05:08 2025, Felix Ulrich-Pur, RW3 slab, 30, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 124.4 MeV/u, Low Flux High, Helium, Good, 1:06, 1:14, 8, , RW3, 1cm 
80Mb/s Events and 20Mb/s rejected

PreTriggerWindow 3360ns and PostTriggerWindow 640ns
Entry  Sun Jun 22 01:05:13 2025, Julia Müllner, 124.4 MeV mouse, 32, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, Good, 1:04, 1:13, 9, , ,  
axis 1: 13

axis 2: -4
Entry  Sun Dec 7 00:47:00 2025, Felix Ulrich-Pur, RW3 slab, 29, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 124.4 MeV/u, Low Flux High, Helium, Good, 00:47, 1:04, 17, , RW3, 1cm 
45Mb/s Events and 1Mb/s rejected

PreTriggerWindow 640ns and PostTriggerWindow 85ns
Entry  Sat Dec 6 19:47:32 2025, Felix Ulrich-Pur, 800MeV systemtest, 15, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 800 MeV, Low Flux High, Proton, Good, 19:48, 19:57, 9, , None,  
PreTriggerWindow: 640ns and PostTriggerWindow: 3.36µs

25Mb/s Events and 25Mb/s rejected
Entry  Sat Jun 21 19:35:59 2025, Julia Müllner, 63.3 MeV systemtest , 10, TOF-Cal GSI, 63.3 MeV/u, Low Flux High, Helium, Good, 19:37, 19:53, 16, , ,  
 
Entry  Sat Dec 6 19:20:24 2025, Felix Ulrich-Pur, 800MeV systemtest, 14, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 800 MeV, Low Flux High, Proton, Good, 19:30, 19:45, 15, , None,  
3360ns PreTriggerWindow and 640ns PostTriggerWindow

Had to restart eventbuilder at 19:39 due to high rejected rate

60Mb/s Events and 10-15Mb/s rejected
Entry  Sat Jun 21 19:22:45 2025, Julia Müllner, 73.2 MeV systemtest , 9, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Good, 19:23, 19:35, 12, , ,  
Threshold change from 50 to 500

10GB collected
Entry  Sat Mar 15 18:37:36 2025, RD50 Generic User, Slab Test Water 3cm, 11, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 18:41, 19:28, 47, , Plastic Water Slabs, 3cm 
RaMon Rate 1.5MHz
Entry  Sat Jun 21 18:22:28 2025, Julia Müllner, 73.2 MeV systemtest , 8, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Crap, 19:10, 19:21, 11, , ,  
new callibration was done, dimanond detector connected to readout

Threshold = 4000

thresholds were too low -> run was canceled
Entry  Sat Dec 6 18:36:14 2025, Felix Ulrich-Pur, 800MeV systemtest, 13, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 800 MeV, Low Flux Very Low, Proton, Good, 18:53, 19:18, 25, , None,  
Run nr. 12 wasn't recorded.

new calib from this run on
Entry  Sat Mar 15 17:30:18 2025, RD50 Generic User, Slab Test Water 2cm, 10, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 17:30, 18:24, 54, , Plastic Water Slabs, 2cm 
RaMon Rate 1.5 MHz
Entry  Sat Dec 6 18:08:39 2025, Felix Ulrich-Pur, 800MeV systemtest, 11, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 800 MeV, Low Flux High, Proton, Good, 18:16, 18:23, 7, , None,  
adjusted threshold for double-sided LGAD (accounted for polarity of signal)
Entry  Sat Jun 21 18:05:21 2025, Julia Müllner, 97.2 MeV systemtest , 7, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 18:06, 18:21, 15, , ,  
Threshold set to 2000

50GB data collected

Room Entry Request: 18:21
Entry  Sat Dec 6 17:45:43 2025, Felix Ulrich-Pur, 402MeV/u systemtest, 10, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, Low Flux High, Helium, Good, 17:47, 18:08, 21, , None,  
threshold = 2000
Entry  Sat Jun 21 17:54:27 2025, Julia Müllner, 97.2 MeV systemtest , 6, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:56, 18:04, 8, , ,  
Threshold set to 4000

40GB data collected
Entry  Sat Jun 21 17:13:34 2025, Julia Müllner, 97.2 MeV systemtest , 5, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:31, 17:54, 23, , ,  
Threshold set to 3000

moved Ripple filters back in 

100GB data collected
Entry  Sat Dec 6 17:24:05 2025, Felix Ulrich-Pur, 402MeV/u systemtest, 9, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, Low Flux High, Helium, Good, 17:24, 17:45, 21, , None,  
17:43: eventbuilder restart since lots of rejected triggers 
Entry  Sat Mar 15 16:50:39 2025, RD50 Generic User, Slab Test Water 1cm, 9, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 16:35, 17:23, 48, , Plastic Water Slabs, 1cm 
RaMon Rate: 1.3MHz
Entry  Sat Dec 6 17:12:41 2025, Felix Ulrich-Pur, 402MeV/u systemtest, 8, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, Low Flux High, Helium, Good, 17:15, 17:22, 7, , None,  
threshold = 2000

PreTriggerWindow 640ns und PostTriggerWindow 85ns
Entry  Sat Jun 21 17:01:05 2025, Julia Müllner, 97.2 MeV systemtest , 4, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 16:58, 17:11, 13, , ,  
Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12.
ELOG V3.1.5-fc6679b