Threshold set to 5000
dead channels on last LGAD, changed trigger from LGAD 12 to LGAD 11
Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12.
Threshold set to 3000
moved Ripple filters back in
100GB data collected
Threshold set to 4000
40GB data collected
Threshold set to 2000
50GB data collected
Room Entry Request: 18:21
new callibration was done, dimanond detector connected to readout
Threshold = 4000
thresholds were too low -> run was canceled
Threshold change from 50 to 500
10GB collected
16GB collected
16.2 GB collected
last events already with 400MeV/u
rejected roughly 10-20%, 8MHz beam
rejected quite a lot of data later -> eventloader restarted
1.041 WET RW3 (mm)
Recorded data: 20GB
auf hades p81 sind alle files ab 008 einschließend sind keine daten sonder kalibrationspulse
position 23 in x (axis 2) and 9 in y (axis 1)