  Testbeams at MedAustron in 2025, Page 8 of 10  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energydown Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  69   Sat Mar 15 16:50:39 2025 RD50 Generic UserSlab Test Water 1cm9Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood16:3517:2348 Plastic Water Slabs1cm

RaMon Rate: 1.3MHz

  70   Sat Mar 15 17:30:18 2025 RD50 Generic UserSlab Test Water 2cm10Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 17:3018:2454 Plastic Water Slabs2cm

RaMon Rate 1.5 MHz

  71   Sat Mar 15 18:37:36 2025 RD50 Generic UserSlab Test Water 3cm11Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 18:4119:2847 Plastic Water Slabs3cm

RaMon Rate 1.5MHz

  72   Sat Mar 15 19:37:42 2025 RD50 Generic UserSlab Test Water 4cm12Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 19:3920:4162 Plastic Water Slabs4cm

RaMon Rate 1.4MHz

  73   Sat Mar 15 21:25:18 2025 RD50 Generic UserSlab Test Water 5cm14Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood21:2621:5024 Plastic Water Slabs5cm

RaMon rate: 4.5MHz

  74   Sat Mar 15 21:29:28 2025 RD50 Generic UserSlab and rate testing (with Michael)13Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood20:4421:2238 Plastic Water Slabs4cm

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600

  77   Sat Jun 21 16:30:44 2025 Julia Müllner205.2 MeV systemtest 3TOF-Cal GSI205.2 MeV/uLow Flux HighHeliumUnknown16:3816:5719   

Threshold set to 5000

dead channels on last LGAD, changed trigger from LGAD 12 to LGAD 11

  88   Sat Jun 21 20:24:05 2025 Julia Müllner205.2 MeV systemtest 14TOF-Cal GSI205.2 MeV/uLow Flux HighHeliumGood20:2420:328   

last events already with 400MeV/u

  87   Sat Jun 21 20:15:25 2025 Julia Müllner177.8 MeV systemtest 13TOF-Cal GSI177.8 MeV/uLow Flux HighHeliumGood20:1620:237   

16.2 GB collected

  43   Sat Mar 15 03:29:19 2025 elog-producerenergy scans228TJ-Monopix2175.3 MeVLow Flux Very LowProtonUnknown15.03.2025 03:20:0215.03.2025 03:29:459HVNone 
automatic log for run 228
Comment:
  86   Sat Jun 21 20:05:49 2025 Julia Müllner147.2 MeV systemtest 12TOF-Cal GSI147.2 MeV/uLow Flux HighHeliumGood20:0620:159   
  44   Sat Mar 15 03:39:19 2025 elog-producerenergy scans229TJ-Monopix2145.4 MeVLow Flux Very LowProtonUnknown15.03.2025 03:30:4215.03.2025 03:39:459HVNone 
automatic log for run 229
Comment:
  65   Sat Mar 15 11:46:28 2025 RD50 Generic UserSlab Measurement 145MeV5Sandwich-iCT setup(GSI)+RaMon145.4 MeVLow Flux MediumProtonGood11:4813:1385   

RaMon Rate 600kHz

front sensors 200mu: ~1kHz pro Streifen

Comments:

change of the trigger settings inbetween, we saw inefficency on all detectors

  85   Sat Jun 21 19:54:12 2025 Julia Müllner124.4 MeV systemtest 11TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood19:5420:0511   

16GB collected

  90   Sat Jun 21 20:42:42 2025 Julia Müllner124.4 MeV/u w slabs16TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood21:0121:109 PTW Slabs1cm

1.041 WET RW3 (mm)

  91   Sat Jun 21 21:11:04 2025 Julia Müllner124.4 MeV/u w 2slabs17TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood21:1621:2913 PTW Slabs2cm
  92   Sat Jun 21 21:33:45 2025 Julia Müllner124.4 MeV/u w 3slabs18TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood21:3421:4713 PTW Slabs3cm
  93   Sat Jun 21 21:47:40 2025 Julia Müllner124.4 MeV/u w 4slabs19TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood21:5122:0514 PTW Slabs4cm
  94   Sat Jun 21 22:04:52 2025 Julia Müllner124.4 MeV w slab20TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood22:0922:2112 PTW Slabs0.5cm

Recorded data: 20GB

  95   Sat Jun 21 22:21:56 2025 Julia Müllner124.4 MeV w slab21TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood22:2622:359 PTW Slabs0.2cm

auf hades p81 sind alle files ab 008 einschließend sind keine daten sonder kalibrationspulse