Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-MA2018
testbeam-MA2019
testbeam-MA2020
testbeam-MA2021
testbeam-MA2023
testbeam-MA2024
testbeam-MA2025
Testbeams at MedAustron in 2025, Page 7 of 10
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
DSSD-Tracker
RD50-MPW4
TJ-Monopix2
TOF-Cal GSI
RaMon
TOF-Cal GSI \(TRB)+DOGMA setup\(diamond+LGAD)+RaMon
Sandwich-iCT setup\(GSI)+RaMon
-- Beam Energy --
800 MeV
252.7 MeV
194.3 MeV
175.3 MeV
145.4 MeV
100.4 MeV
83 MeV
62.4 MeV
115.7MeV
205.2 MeV/u
177.8 MeV/u
147.2 MeV/u
124.4 MeV/u
97.2MeV/u
73.2 MeV/u
63.3 MeV/u
402MeV/u
197 Entries
Goto page
Previous
1
,
2
,
3
...
6
, 7,
8
,
9
,
10
Next
All
ID
Date
Author
Subject
Run Number
DUT
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Frontend
Phantom
Phantom thickness
Text
63
Sat Mar 15 09:51:23 2025
RD50 Generic User
Alignment Run 800MeV
3
Sandwich-iCT setup(GSI)+RaMon
800 MeV
Low Flux High
Proton
Unknown
9:44
10:03
19
RaMon Rate 2MHz
front sensors 200mu: ~50-100kHz
pro Streifen
64
Sat Mar 15 10:07:28 2025
RD50 Generic User
Alignment Run 252MeV
4
Sandwich-iCT setup(GSI)+RaMon
252.7 MeV
Low Flux Medium
Proton
Good
10:07
11:43
96
RaMon Rate 1MHz
front sensors 200mu: ~10-25kHz
pro Streifen
78
Sat Jun 21 17:01:05 2025
Julia Müllner
97.2 MeV systemtest
4
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
16:58
17:11
13
Data was good, we have to shuft the setup
in x direction and slightly down. Enter room
request 17:12.
79
Sat Jun 21 17:13:34 2025
Julia Müllner
97.2 MeV systemtest
5
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
17:31
17:54
23
Threshold set to 3000
moved Ripple filters back in
100GB data collected
80
Sat Jun 21 17:54:27 2025
Julia Müllner
97.2 MeV systemtest
6
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
17:56
18:04
8
Threshold set to 4000
40GB data collected
81
Sat Jun 21 18:05:21 2025
Julia Müllner
97.2 MeV systemtest
7
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
18:06
18:21
15
Threshold set to 2000
50GB data collected
Room Entry Request: 18:21
75
Sat Jun 21 14:30:29 2025
Julia Müllner
800MeV systemtest
1
TOF-Cal GSI
800 MeV
Low Flux High
Proton
Good
14:45
15:42
57
first spills were done with low flux medium,
changed to high at 14:49
again changed to medium at 14:55
76
Sat Jun 21 15:43:47 2025
Julia Müllner
800MeV systemtest
2
TOF-Cal GSI
800 MeV
Low Flux High
Proton
Good
16:02
16:29
27
Threshold set to 1000
Factor 4 chosen for future runs,
80 GB in total recorded in this run
82
Sat Jun 21 18:22:28 2025
Julia Müllner
73.2 MeV systemtest
8
TOF-Cal GSI
73.2 MeV/u
Low Flux High
Helium
Crap
19:10
19:21
11
new callibration was done, dimanond detector
connected to readout
Threshold = 4000
83
Sat Jun 21 19:22:45 2025
Julia Müllner
73.2 MeV systemtest
9
TOF-Cal GSI
73.2 MeV/u
Low Flux High
Helium
Good
19:23
19:35
12
Threshold change from 50 to 500
10GB collected
84
Sat Jun 21 19:35:59 2025
Julia Müllner
63.3 MeV systemtest
10
TOF-Cal GSI
63.3 MeV/u
Low Flux High
Helium
Good
19:37
19:53
16
89
Sat Jun 21 20:32:58 2025
Julia Müllner
402MeV systemtest
15
TOF-Cal GSI
402MeV/u
Low Flux High
Helium
Good
20:35
20:47
12
rejected roughly 10-20%, 8MHz beam
rejected quite a lot of data later
-> eventloader restarted
132
Sun Jun 22 05:16:32 2025
Julia Müllner
402 MeV mouse
58
TOF-Cal GSI
402MeV/u
Low Flux High
Carbon
Good
5:29
6:00
31
axis 1: 5
axis 2: 2
degrader 10, mouse is still inside
77
Sat Jun 21 16:30:44 2025
Julia Müllner
205.2 MeV systemtest
3
TOF-Cal GSI
205.2 MeV/u
Low Flux High
Helium
Unknown
16:38
16:57
19
Threshold set to 5000
dead channels on last LGAD, changed
trigger from LGAD 12 to LGAD 11
88
Sat Jun 21 20:24:05 2025
Julia Müllner
205.2 MeV systemtest
14
TOF-Cal GSI
205.2 MeV/u
Low Flux High
Helium
Good
20:24
20:32
8
last events already with 400MeV/u
14
Fri Mar 14 21:54:32 2025
elog-producer
1st tests with beam
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
HV
None
about to get p+
15
Fri Mar 14 22:09:23 2025
elog-producer
1st tests with beam
200
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
14.03.2025 22:04:01
14.03.2025 22:09:49
5
HV
None
automatic log for run 200
Comment:
16
Fri Mar 14 22:13:14 2025
elog-producer
1st tests with beam
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
HV
None
APV25 latency 42 required for these input
stretches
17
Fri Mar 14 22:20:25 2025
elog-producer
1st tests with beam
201
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
14.03.2025 22:11:23
14.03.2025 22:20:51
9
HV
None
automatic log for run 201
Comment:
18
Fri Mar 14 22:41:04 2025
elog-producer
1st tests with beam
202
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
14.03.2025 22:38:51
14.03.2025 22:41:30
2
HV
None
automatic log for run 202