Sat Aug 16 20:21:34 2025, elog_producer, Castid, 105, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Crap, 16.08.2025 20:21:28, 16.08.2025 20:21:36, 0, HV, None,
|
automatic log for run 105
Comment:
self.configure_rx(delay=2, rd_frz_dly=2) (20x) |
Sat Aug 16 20:47:06 2025, elog_producer, Castid, 106, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 16.08.2025 20:35:07, 16.08.2025 20:47:08, 12, HV, None,
|
automatic log for run 106
Comment:
self.configure_rx(delay=2, rd_frz_dly=2) (20x) |
Sat Aug 16 20:58:19 2025, elog_producer, Castid, 107, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 16.08.2025 20:47:55, 16.08.2025 20:58:21, 10, HV, None,
|
automatic log for run 107
Comment:
self.configure_rx(delay=2, rd_frz_dly=2) (20x) |
Sat Aug 16 21:08:36 2025, elog_producer, Castid, 108, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 16.08.2025 20:59:05, 16.08.2025 21:08:39, 9, HV, None,
|
automatic log for run 108
Comment:
self.configure_rx(delay=2, rd_frz_dly=2) (20x) |
Sat Mar 15 08:52:52 2025, RD50 Generic User, Alignment Run 800MeV, 2, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Medium, Proton, Good, 08:22, 9:40, 78, , ,
|
RaMon Rate 400kHz
front sensors 200mu: ~10-20kHz pro Streifen
Comments: |
Sat Mar 15 08:58:26 2025, RD50 Generic User, Alignment Run 800MeV, 1, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Low, Proton, Good, 07:40, 08:20, 40, , ,
|
RaMon Rate not measured
front sensors 200mu: ~40-60Hz pro Streifen
Comments: |
Sat Mar 15 09:51:23 2025, RD50 Generic User, Alignment Run 800MeV, 3, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux High, Proton, Unknown, 9:44, 10:03, 19, , ,
|
RaMon Rate 2MHz
front sensors 200mu: ~50-100kHz pro Streifen
Comments: |
Sat Mar 15 10:07:28 2025, RD50 Generic User, Alignment Run 252MeV, 4, Sandwich-iCT setup(GSI)+RaMon, 252.7 MeV, Low Flux Medium, Proton, Good, 10:07, 11:43, 96, , ,
|
RaMon Rate 1MHz
front sensors 200mu: ~10-25kHz pro Streifen |
Sat Mar 15 11:46:28 2025, RD50 Generic User, Slab Measurement 145MeV, 5, Sandwich-iCT setup(GSI)+RaMon, 145.4 MeV, Low Flux Medium, Proton, Good, 11:48, 13:13, 85, , ,
|
RaMon Rate 600kHz
front sensors 200mu: ~1kHz pro Streifen
Comments: |
Sat Mar 15 13:15:25 2025, RD50 Generic User, Slab Measurement 205MeV, 6, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 13:27, 14:49, 82, , ,
|
RaMon Rate 1.3 MHz
Comments:
We entered the room and connected the second LAN Port to the ReadOut-PC. The Eventbuilder-parameter got changed. |
Sat Mar 15 15:02:39 2025, RD50 Generic User, Rate testing, 7, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 15:04, 15:25, 21, , ,
|
RaMon Rate 4.5MHz
Comments:
From File 7 until 21 optional false, and from 22 true (everything deleted) |
Sat Mar 15 15:26:08 2025, RD50 Generic User, Rate testing, 8, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 15:31, 16:30, 59, , ,
|
RaMon Rate: 1.3MHz
Comments:
Tested different evenbuilder settings which made things worse, probably switch is the bottleneck, changed rate settings inbetween, requires sergey |
Sat Mar 15 16:50:39 2025, RD50 Generic User, Slab Test Water 1cm, 9, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 16:35, 17:23, 48, , Plastic Water Slabs, 1cm
|
RaMon Rate: 1.3MHz |
Sat Mar 15 17:30:18 2025, RD50 Generic User, Slab Test Water 2cm, 10, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 17:30, 18:24, 54, , Plastic Water Slabs, 2cm
|
RaMon Rate 1.5 MHz |
Sat Mar 15 18:37:36 2025, RD50 Generic User, Slab Test Water 3cm, 11, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 18:41, 19:28, 47, , Plastic Water Slabs, 3cm
|
RaMon Rate 1.5MHz |
Sat Mar 15 19:37:42 2025, RD50 Generic User, Slab Test Water 4cm, 12, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 19:39, 20:41, 62, , Plastic Water Slabs, 4cm
|
RaMon Rate 1.4MHz |
Sat Mar 15 21:25:18 2025, RD50 Generic User, Slab Test Water 5cm, 14, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 21:26, 21:50, 24, , Plastic Water Slabs, 5cm
|
RaMon rate: 4.5MHz |
Sat Mar 15 21:29:28 2025, RD50 Generic User, Slab and rate testing (with Michael), 13, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 20:44, 21:22, 38, , Plastic Water Slabs, 4cm
|
totzeit optimieren und deadtime finden
hex wert mal 10ns deadtime
13 ab file 10 besat effort |
Sat Jun 21 14:30:29 2025, Julia Müllner, 800MeV systemtest , 1, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 14:45, 15:42, 57, , ,
|
first spills were done with low flux medium, changed to high at 14:49
again changed to medium at 14:55
again changed to high at 15:00 |
Sat Jun 21 15:43:47 2025, Julia Müllner, 800MeV systemtest , 2, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 16:02, 16:29, 27, , ,
|
Threshold set to 1000
Factor 4 chosen for future runs, 80 GB in total recorded in this run |
|