Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 7 of 10  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Sat Mar 15 09:51:23 2025, RD50 Generic User, Alignment Run 800MeV, 3, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux High, Proton, Unknown, 9:44, 10:03, 19, , ,  
RaMon Rate 2MHz

front sensors 200mu: ~50-100kHz pro Streifen

Comments:
Entry  Sat Mar 15 10:07:28 2025, RD50 Generic User, Alignment Run 252MeV, 4, Sandwich-iCT setup(GSI)+RaMon, 252.7 MeV, Low Flux Medium, Proton, Good, 10:07, 11:43, 96, , ,  
RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen
Entry  Sat Jun 21 17:01:05 2025, Julia Müllner, 97.2 MeV systemtest , 4, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 16:58, 17:11, 13, , ,  
Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12.
Entry  Sat Jun 21 17:13:34 2025, Julia Müllner, 97.2 MeV systemtest , 5, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:31, 17:54, 23, , ,  
Threshold set to 3000

moved Ripple filters back in 

100GB data collected
Entry  Sat Jun 21 17:54:27 2025, Julia Müllner, 97.2 MeV systemtest , 6, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:56, 18:04, 8, , ,  
Threshold set to 4000

40GB data collected
Entry  Sat Jun 21 18:05:21 2025, Julia Müllner, 97.2 MeV systemtest , 7, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 18:06, 18:21, 15, , ,  
Threshold set to 2000

50GB data collected

Room Entry Request: 18:21
Entry  Sat Jun 21 14:30:29 2025, Julia Müllner, 800MeV systemtest , 1, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 14:45, 15:42, 57, , ,  
first spills were done with low flux medium, changed to high at 14:49

again changed to medium at 14:55

again changed to high at 15:00
Entry  Sat Jun 21 15:43:47 2025, Julia Müllner, 800MeV systemtest , 2, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 16:02, 16:29, 27, , ,  
Threshold set to 1000

Factor 4 chosen for future runs, 80 GB in total recorded in this run
Entry  Sat Jun 21 18:22:28 2025, Julia Müllner, 73.2 MeV systemtest , 8, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Crap, 19:10, 19:21, 11, , ,  
new callibration was done, dimanond detector connected to readout

Threshold = 4000

thresholds were too low -> run was canceled
Entry  Sat Jun 21 19:22:45 2025, Julia Müllner, 73.2 MeV systemtest , 9, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Good, 19:23, 19:35, 12, , ,  
Threshold change from 50 to 500

10GB collected
Entry  Sat Jun 21 19:35:59 2025, Julia Müllner, 63.3 MeV systemtest , 10, TOF-Cal GSI, 63.3 MeV/u, Low Flux High, Helium, Good, 19:37, 19:53, 16, , ,  
 
Entry  Sat Jun 21 20:32:58 2025, Julia Müllner, 402MeV systemtest , 15, TOF-Cal GSI, 402MeV/u, Low Flux High, Helium, Good, 20:35, 20:47, 12, , ,  
rejected roughly 10-20%, 8MHz beam

rejected quite a lot of data later -> eventloader restarted
Entry  Sun Jun 22 05:16:32 2025, Julia Müllner, 402 MeV mouse, 58, TOF-Cal GSI, 402MeV/u, Low Flux High, Carbon, Good, 5:29, 6:00, 31, , ,  
axis 1: 5

axis 2: 2

degrader 10, mouse is still inside
Entry  Sat Jun 21 16:30:44 2025, Julia Müllner, 205.2 MeV systemtest , 3, TOF-Cal GSI, 205.2 MeV/u, Low Flux High, Helium, Unknown, 16:38, 16:57, 19, , ,  
Threshold set to 5000

dead channels on last LGAD, changed trigger from LGAD 12 to LGAD 11
Entry  Sat Jun 21 20:24:05 2025, Julia Müllner, 205.2 MeV systemtest , 14, TOF-Cal GSI, 205.2 MeV/u, Low Flux High, Helium, Good, 20:24, 20:32, 8, , ,  
last events already with 400MeV/u
Entry  Fri Mar 14 21:54:32 2025, elog-producer, 1st tests with beam, , TJ-Monopix2, 800 MeV, Low Flux Very Low, Proton, Unknown, , , , HV, None,  
about to get p+
Entry  Fri Mar 14 22:09:23 2025, elog-producer, 1st tests with beam, 200, TJ-Monopix2, 800 MeV, Low Flux Very Low, Proton, Unknown, 14.03.2025 22:04:01, 14.03.2025 22:09:49, 5, HV, None,  tjmonopix2.conftjmonopix2_1.conf
automatic log for run 200
Comment:
Entry  Fri Mar 14 22:13:14 2025, elog-producer, 1st tests with beam, , TJ-Monopix2, 800 MeV, Low Flux Very Low, Proton, Unknown, , , , HV, None,  
APV25 latency 42 required for these input stretches
Entry  Fri Mar 14 22:20:25 2025, elog-producer, 1st tests with beam, 201, TJ-Monopix2, 800 MeV, Low Flux Very Low, Proton, Unknown, 14.03.2025 22:11:23, 14.03.2025 22:20:51, 9, HV, None,  tjmonopix2.conftjmonopix2_1.conf
automatic log for run 201
Comment:
Entry  Fri Mar 14 22:41:04 2025, elog-producer, 1st tests with beam, 202, TJ-Monopix2, 800 MeV, Low Flux Very Low, Proton, Unknown, 14.03.2025 22:38:51, 14.03.2025 22:41:30, 2, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 202
Comment:
ELOG V3.1.5-fc6679b