Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 6 of 13  Not logged in ELOG logo
Entry  Sat Sep 20 19:49:27 2025, elog_producer, Caribou 1.5, 1031, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Unknown, 20.09.2025 19:44:43, 20.09.2025 19:49:39, 4, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1031
Comment:
bias voltage scan
Entry  Sat Mar 15 21:29:28 2025, RD50 Generic User, Slab and rate testing (with Michael), 13, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 20:44, 21:22, 38, , Plastic Water Slabs, 4cm 
totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
Entry  Fri Mar 14 20:40:06 2025, elog-producer, validating setup, 112, TJ-Monopix2, 800 MeV, Low Flux Very Low, Proton, Unknown, 14.03.2025 20:07:47, 14.03.2025 20:40:32, 32, HV, None,  tjmonopix2.conf
automatic log for run 112
Comment:
still testing nonsense
Entry  Sun Jun 22 05:16:32 2025, Julia Müllner, 402 MeV mouse, 58, TOF-Cal GSI, 402MeV/u, Low Flux High, Carbon, Good, 5:29, 6:00, 31, , ,  
axis 1: 5

axis 2: 2

degrader 10, mouse is still inside
Entry  Sat Mar 15 01:29:25 2025, elog-producer, Fast RO Test, 215, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 15.03.2025 01:26:13, 15.03.2025 01:29:51, 3, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 215
Comment:
Lower rates then Very low settings, so just a quick run here
Entry  Sat Mar 15 02:53:18 2025, elog-producer, energy scans, 224, TJ-Monopix2, 252.7 MeV, Low Flux Very Low, Proton, Unknown, 15.03.2025 02:49:44, 15.03.2025 02:53:44, 3, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 224
Comment:
Entry  Sat Mar 15 05:42:14 2025, elog-producer, test 8b10b, 246, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 15.03.2025 05:38:42, 15.03.2025 05:42:41, 3, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 246
Comment:
BDAQ Board to Monopix connection swapped - and now the W02R01 chip works fine with full rate
Entry  Tue Aug 5 17:49:22 2025, elog_producer, Castid, 50, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Crap, 05.08.2025 17:46:44, 05.08.2025 17:49:50, 3, HV, None,  tjmonopix2_tracker.conf
automatic log for run 50
Comment:
Entry  Sat Aug 16 15:11:38 2025, elog_producer, Castid, 57, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 16.08.2025 15:08:18, 16.08.2025 15:11:39, 3, HV, None,  tjmonopix2.conf
automatic log for run 57
Comment:
Testrun with beam, TLU does not trigger but monopixes should be fine
Entry  Sat Aug 16 16:03:13 2025, elog_producer, Castid, 63, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Crap, 16.08.2025 15:59:56, 16.08.2025 16:03:15, 3, HV, None,  tjmonopix2.conf
automatic log for run 63
Comment:
debug tlu
Entry  Sat Aug 16 18:45:42 2025, elog_producer, Castid, 87, TJ-Monopix2, 800 MeV, Low Flux High, Proton, Crap, 16.08.2025 18:42:42, 16.08.2025 18:45:44, 3, HV, None,  tjmonopix2.conf
automatic log for run 87
Comment:
self.configure_rx(delay=10, rd_frz_dly=10) (4x)
Entry  Sat Aug 16 19:22:06 2025, elog_producer, Castid, 93, TJ-Monopix2, 800 MeV, Low Flux High, Proton, Crap, 16.08.2025 19:18:19, 16.08.2025 19:22:08, 3, HV, None,  tjmonopix2.conf
automatic log for run 93
Comment:
self.configure_rx(delay=30, rd_frz_dly=30) (1.5x)
Entry  Sat Aug 16 20:18:49 2025, elog_producer, Castid, 103, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Crap, 16.08.2025 20:15:36, 16.08.2025 20:18:51, 3, HV, None,  tjmonopix2.conf
automatic log for run 103
Comment:
self.configure_rx(delay=2, rd_frz_dly=2) (20x)
Entry  Sat Sep 20 18:08:47 2025, elog_producer, Caribou 1.5, 1016, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 20.09.2025 18:05:28, 20.09.2025 18:08:58, 3, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1016
Comment:
Bias voltage scan
Entry  Tue Aug 5 16:45:37 2025, elog_producer, Castid, 47, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Crap, 05.08.2025 16:16:11, 05.08.2025 16:46:04, 29, HV, None,  tjmonopix2_tracker.conf
automatic log for run 47
Comment:
Test debugging tests for debugging
Entry  Sat Jun 21 15:43:47 2025, Julia Müllner, 800MeV systemtest , 2, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 16:02, 16:29, 27, , ,  
Threshold set to 1000

Factor 4 chosen for future runs, 80 GB in total recorded in this run
Entry  Sat Mar 15 21:25:18 2025, RD50 Generic User, Slab Test Water 5cm, 14, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 21:26, 21:50, 24, , Plastic Water Slabs, 5cm 
RaMon rate: 4.5MHz
Entry  Sat Jun 21 17:13:34 2025, Julia Müllner, 97.2 MeV systemtest , 5, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:31, 17:54, 23, , ,  
Threshold set to 3000

moved Ripple filters back in 

100GB data collected
Entry  Sat Mar 15 15:02:39 2025, RD50 Generic User, Rate testing, 7, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 15:04, 15:25, 21, , ,  
RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)
Entry  Thu Mar 13 16:36:43 2025, tb-crew, validating setup, 95, TJ-Monopix2, 800 MeV, Low Flux Very Low, Proton, Unknown, 13.03.2025 16:34:19, 13.03.2025 16:37:08, 2, HV, None,  tjmonopix2.conf
automatic log for run 95
Comment:
tests without beam 
ELOG V3.1.5-fc6679b