Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 5 of 7  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantomdown Phantom thickness Text Attachments
  75   Sat Jun 21 14:30:29 2025 Julia Müllner800MeV systemtest 1TOF-Cal GSI800 MeVLow Flux HighProtonGood14:4515:4257   first spills were done with low flux medium,
changed to high at 14:49

again changed to medium at 14:55
  
  76   Sat Jun 21 15:43:47 2025 Julia Müllner800MeV systemtest 2TOF-Cal GSI800 MeVLow Flux HighProtonGood16:0216:2927   Threshold set to 1000

Factor 4 chosen for future runs,
80 GB in total recorded in this run
  
  77   Sat Jun 21 16:30:44 2025 Julia Müllner205.2 MeV systemtest 3TOF-Cal GSI205.2 MeV/uLow Flux HighHeliumUnknown16:3816:5719   Threshold set to 5000

dead channels on last LGAD, changed
trigger from LGAD 12 to LGAD 11
  
  78   Sat Jun 21 17:01:05 2025 Julia Müllner97.2 MeV systemtest 4TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood16:5817:1113   Data was good, we have to shuft the setup
in x direction and slightly down. Enter room
request 17:12.
  
  79   Sat Jun 21 17:13:34 2025 Julia Müllner97.2 MeV systemtest 5TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood17:3117:5423   Threshold set to 3000

moved Ripple filters back in 

100GB data collected
  
  80   Sat Jun 21 17:54:27 2025 Julia Müllner97.2 MeV systemtest 6TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood17:5618:048   Threshold set to 4000

40GB data collected
  
  81   Sat Jun 21 18:05:21 2025 Julia Müllner97.2 MeV systemtest 7TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood18:0618:2115   Threshold set to 2000

50GB data collected

Room Entry Request: 18:21
  
  82   Sat Jun 21 18:22:28 2025 Julia Müllner73.2 MeV systemtest 8TOF-Cal GSI73.2 MeV/uLow Flux HighHeliumCrap19:1019:2111   new callibration was done, dimanond detector
connected to readout

Threshold = 4000
  
  83   Sat Jun 21 19:22:45 2025 Julia Müllner73.2 MeV systemtest 9TOF-Cal GSI73.2 MeV/uLow Flux HighHeliumGood19:2319:3512   Threshold change from 50 to 500

10GB collected
  
  84   Sat Jun 21 19:35:59 2025 Julia Müllner63.3 MeV systemtest 10TOF-Cal GSI63.3 MeV/uLow Flux HighHeliumGood19:3719:5316       
  85   Sat Jun 21 19:54:12 2025 Julia Müllner124.4 MeV systemtest 11TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood19:5420:0511   16GB collected   
  86   Sat Jun 21 20:05:49 2025 Julia Müllner147.2 MeV systemtest 12TOF-Cal GSI147.2 MeV/uLow Flux HighHeliumGood20:0620:159       
  87   Sat Jun 21 20:15:25 2025 Julia Müllner177.8 MeV systemtest 13TOF-Cal GSI177.8 MeV/uLow Flux HighHeliumGood20:1620:237   16.2 GB collected   
  88   Sat Jun 21 20:24:05 2025 Julia Müllner205.2 MeV systemtest 14TOF-Cal GSI205.2 MeV/uLow Flux HighHeliumGood20:2420:328   last events already with 400MeV/u   
  89   Sat Jun 21 20:32:58 2025 Julia Müllner402MeV systemtest 15TOF-Cal GSI402MeV/uLow Flux HighHeliumGood20:3520:4712   rejected roughly 10-20%, 8MHz beam

rejected quite a lot of data later
-> eventloader restarted
  
  96   Sat Jun 21 23:23:15 2025 Julia Müllner124.4 MeV mouse22TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood23:2423:3814   position 23 in x (axis 2) and 9 in
y (axis 1)
  
  97   Sat Jun 21 23:38:17 2025 Julia Müllner124.4 MeV mouse23TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood23:4123:498   axis 1: 9

axis 2: 20

24Gb of collected data
  
  98   Sat Jun 21 23:49:42 2025 Julia Müllner124.4 MeV mouse24TOF-Cal GSI124.4 MeV/uLow Flux HighHelium 23:5023:599   axis 1: 9

axis 2: 17 
  
  99   Sun Jun 22 00:00:11 2025 Julia Müllner124.4 MeV mouse25TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood0:000:088   axis 1: 9

axis 2: 14
  
  100   Sun Jun 22 00:08:17 2025 Julia Müllner124.4 MeV mouse26TOF-Cal GSI124.4 MeV/uLow Flux HighHelium 0:090:178   axis 1: 9

axis 2: 11
  
ELOG V3.1.5-fc6679b