Sat Jun 21 14:30:29 2025, Julia Müllner, 800MeV systemtest , 1, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 14:45, 15:42, 57, , ,
|
first spills were done with low flux medium, changed to high at 14:49
again changed to medium at 14:55
again changed to high at 15:00 |
Sat Jun 21 15:43:47 2025, Julia Müllner, 800MeV systemtest , 2, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 16:02, 16:29, 27, , ,
|
Threshold set to 1000
Factor 4 chosen for future runs, 80 GB in total recorded in this run |
Sat Jun 21 16:30:44 2025, Julia Müllner, 205.2 MeV systemtest , 3, TOF-Cal GSI, 205.2 MeV/u, Low Flux High, Helium, Unknown, 16:38, 16:57, 19, , ,
|
Threshold set to 5000
dead channels on last LGAD, changed trigger from LGAD 12 to LGAD 11 |
Sat Jun 21 17:01:05 2025, Julia Müllner, 97.2 MeV systemtest , 4, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 16:58, 17:11, 13, , ,
|
Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12. |
Sat Jun 21 17:13:34 2025, Julia Müllner, 97.2 MeV systemtest , 5, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:31, 17:54, 23, , ,
|
Threshold set to 3000
moved Ripple filters back in
100GB data collected |
Sat Jun 21 17:54:27 2025, Julia Müllner, 97.2 MeV systemtest , 6, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:56, 18:04, 8, , ,
|
Threshold set to 4000
40GB data collected |
Sat Jun 21 18:05:21 2025, Julia Müllner, 97.2 MeV systemtest , 7, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 18:06, 18:21, 15, , ,
|
Threshold set to 2000
50GB data collected
Room Entry Request: 18:21 |
Sat Jun 21 18:22:28 2025, Julia Müllner, 73.2 MeV systemtest , 8, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Crap, 19:10, 19:21, 11, , ,
|
new callibration was done, dimanond detector connected to readout
Threshold = 4000
thresholds were too low -> run was canceled |
Sat Jun 21 19:22:45 2025, Julia Müllner, 73.2 MeV systemtest , 9, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Good, 19:23, 19:35, 12, , ,
|
Threshold change from 50 to 500
10GB collected |
Sat Jun 21 19:35:59 2025, Julia Müllner, 63.3 MeV systemtest , 10, TOF-Cal GSI, 63.3 MeV/u, Low Flux High, Helium, Good, 19:37, 19:53, 16, , ,
|
|
Sat Jun 21 19:54:12 2025, Julia Müllner, 124.4 MeV systemtest , 11, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, Good, 19:54, 20:05, 11, , ,
|
16GB collected |
Sat Jun 21 20:05:49 2025, Julia Müllner, 147.2 MeV systemtest , 12, TOF-Cal GSI, 147.2 MeV/u, Low Flux High, Helium, Good, 20:06, 20:15, 9, , ,
|
|
Sat Jun 21 20:15:25 2025, Julia Müllner, 177.8 MeV systemtest , 13, TOF-Cal GSI, 177.8 MeV/u, Low Flux High, Helium, Good, 20:16, 20:23, 7, , ,
|
16.2 GB collected |
Sat Jun 21 20:24:05 2025, Julia Müllner, 205.2 MeV systemtest , 14, TOF-Cal GSI, 205.2 MeV/u, Low Flux High, Helium, Good, 20:24, 20:32, 8, , ,
|
last events already with 400MeV/u |
Sat Jun 21 20:32:58 2025, Julia Müllner, 402MeV systemtest , 15, TOF-Cal GSI, 402MeV/u, Low Flux High, Helium, Good, 20:35, 20:47, 12, , ,
|
rejected roughly 10-20%, 8MHz beam
rejected quite a lot of data later -> eventloader restarted |
Sat Jun 21 23:23:15 2025, Julia Müllner, 124.4 MeV mouse, 22, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, Good, 23:24, 23:38, 14, , ,
|
position 23 in x (axis 2) and 9 in y (axis 1) |
Sat Jun 21 23:38:17 2025, Julia Müllner, 124.4 MeV mouse, 23, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, Good, 23:41, 23:49, 8, , ,
|
axis 1: 9
axis 2: 20
24Gb of collected data |
Sat Jun 21 23:49:42 2025, Julia Müllner, 124.4 MeV mouse, 24, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, , 23:50, 23:59, 9, , ,
|
axis 1: 9
axis 2: 17 |
Sun Jun 22 00:00:11 2025, Julia Müllner, 124.4 MeV mouse, 25, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, Good, 0:00, 0:08, 8, , ,
|
axis 1: 9
axis 2: 14 |
Sun Jun 22 00:08:17 2025, Julia Müllner, 124.4 MeV mouse, 26, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, , 0:09, 0:17, 8, , ,
|
axis 1: 9
axis 2: 11 |
|