Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-MA2018
testbeam-MA2019
testbeam-MA2020
testbeam-MA2021
testbeam-MA2023
testbeam-MA2024
testbeam-MA2025
Testbeams at MedAustron in 2025, Page 4 of 4
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
DSSD-Tracker
RD50-MPW4
TJ-Monopix2
TOF-Cal GSI
RaMon
TOF-Cal GSI \(TRB)+DOGMA setup\(diamond+LGAD)+RaMon
Sandwich-iCT setup\(GSI)+RaMon
-- Beam Energy --
800 MeV
252.7 MeV
194.3 MeV
175.3 MeV
145.4 MeV
100.4 MeV
83 MeV
62.4 MeV
115.7MeV
205.2 MeV/u
177.8 MeV/u
147.2 MeV/u
124.4 MeV/u
97.2MeV/u
73.2 MeV/u
63.3 MeV/u
402MeV/u
74 Entries
Goto page
Previous
1
,
2
,
3
, 4
All
ID
Date
Author
Subject
Run Number
DUT
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Frontend
Phantom
Phantom thickness
Text
62
Sat Mar 15 08:58:26 2025
RD50 Generic User
Alignment Run 800MeV
1
Sandwich-iCT setup(GSI)+RaMon
800 MeV
Low Flux Low
Proton
Good
07:40
08:20
40
RaMon Rate not measured
front sensors 200mu: ~40-60Hz pro
Streifen
64
Sat Mar 15 10:07:28 2025
RD50 Generic User
Alignment Run 252MeV
4
Sandwich-iCT setup(GSI)+RaMon
252.7 MeV
Low Flux Medium
Proton
Good
10:07
11:43
96
RaMon Rate 1MHz
front sensors 200mu: ~10-25kHz
pro Streifen
65
Sat Mar 15 11:46:28 2025
RD50 Generic User
Slab Measurement 145MeV
5
Sandwich-iCT setup(GSI)+RaMon
145.4 MeV
Low Flux Medium
Proton
Good
11:48
13:13
85
RaMon Rate 600kHz
front sensors 200mu: ~1kHz pro
Streifen
66
Sat Mar 15 13:15:25 2025
RD50 Generic User
Slab Measurement 205MeV
6
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
Good
13:27
14:49
82
RaMon Rate 1.3 MHz
Comments:
We entered the room and connected
67
Sat Mar 15 15:02:39 2025
RD50 Generic User
Rate testing
7
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux High
Helium
Good
15:04
15:25
21
RaMon Rate 4.5MHz
Comments:
From File 7 until 21 optional false,
69
Sat Mar 15 16:50:39 2025
RD50 Generic User
Slab Test Water 1cm
9
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
Good
16:35
17:23
48
Plastic Water Slabs
1cm
RaMon Rate: 1.3MHz
73
Sat Mar 15 21:25:18 2025
RD50 Generic User
Slab Test Water 5cm
14
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux High
Helium
Good
21:26
21:50
24
Plastic Water Slabs
5cm
RaMon rate: 4.5MHz
74
Sat Mar 15 21:29:28 2025
RD50 Generic User
Slab and rate testing (with Michael)
13
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux High
Helium
Good
20:44
21:22
38
Plastic Water Slabs
4cm
totzeit optimieren und deadtime finden
hex wert mal 10ns deadtime
13 ab file 10 besat effort
27
Fri Mar 14 23:55:03 2025
elog-producer
1st tests with beam
210
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Crap
14.03.2025 23:37:02
14.03.2025 23:55:29
18
HV
None
automatic log for run 210
Comment:
46
Sat Mar 15 04:11:28 2025
elog-producer
energy scans
231
TJ-Monopix2
83 MeV
Low Flux Very Low
Proton
Crap
15.03.2025 04:00:20
15.03.2025 04:11:54
11
HV
None
automatic log for run 231
Comment:
68
Sat Mar 15 15:26:08 2025
RD50 Generic User
Rate testing
8
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
15:31
16:30
59
RaMon Rate: 1.3MHz
Comments:
Tested different evenbuilder settings
70
Sat Mar 15 17:30:18 2025
RD50 Generic User
Slab Test Water 2cm
10
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
17:30
18:24
54
Plastic Water Slabs
2cm
RaMon Rate 1.5 MHz
71
Sat Mar 15 18:37:36 2025
RD50 Generic User
Slab Test Water 3cm
11
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
18:41
19:28
47
Plastic Water Slabs
3cm
RaMon Rate 1.5MHz
72
Sat Mar 15 19:37:42 2025
RD50 Generic User
Slab Test Water 4cm
12
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
19:39
20:41
62
Plastic Water Slabs
4cm
RaMon Rate 1.4MHz