Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 4 of 4  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Settingdown Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness Text Attachments
  69   Sat Mar 15 16:50:39 2025 RD50 Generic UserSlab Test Water 1cm9Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood16:3517:2348 Plastic Water Slabs1cmRaMon Rate: 1.3MHz   
  70   Sat Mar 15 17:30:18 2025 RD50 Generic UserSlab Test Water 2cm10Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 17:3018:2454 Plastic Water Slabs2cmRaMon Rate 1.5 MHz   
  71   Sat Mar 15 18:37:36 2025 RD50 Generic UserSlab Test Water 3cm11Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 18:4119:2847 Plastic Water Slabs3cmRaMon Rate 1.5MHz   
  72   Sat Mar 15 19:37:42 2025 RD50 Generic UserSlab Test Water 4cm12Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 19:3920:4162 Plastic Water Slabs4cmRaMon Rate 1.4MHz   
  32   Sat Mar 15 01:29:25 2025 elog-producerFast RO Test215TJ-Monopix2800 MeVLow Flux LowProtonUnknown15.03.2025 01:26:1315.03.2025 01:29:513HVNone automatic log for run 215
Comment:
Lower rates then Very low settings, so just
 tjmonopix2.initjmonopix2.conf 
  36   Sat Mar 15 02:15:34 2025 elog-producerFast RO Test221TJ-Monopix2800 MeVLow Flux LowProtonUnknown15.03.2025 02:02:1515.03.2025 02:16:0013HVNone automatic log for run 221
Comment:
 tjmonopix2.initjmonopix2.conf 
  40   Sat Mar 15 02:56:07 2025 elog-producerenergy scans225TJ-Monopix2252.7 MeVLow Flux LowProtonUnknown   HVNone 8b10b W02R01, 1 MHz rate (low flux low)   
  62   Sat Mar 15 08:58:26 2025 RD50 Generic UserAlignment Run 800MeV1Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux LowProtonGood07:4008:2040   RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro
Streifen
  
  51   Sat Mar 15 04:39:13 2025 elog-producertest rate limits236TJ-Monopix2800 MeVLow Flux HighProtonUnknown15.03.2025 04:38:0415.03.2025 04:39:391HVNone automatic log for run 236
Comment:
Increase csinti thr to -0.2
 tjmonopix2.initjmonopix2.conf 
  52   Sat Mar 15 04:42:48 2025 elog-producertest rate limits237TJ-Monopix2800 MeVLow Flux HighProtonUnknown15.03.2025 04:40:2815.03.2025 04:43:142HVNone automatic log for run 237
Comment:
Increase csinti thr to -0.3
 tjmonopix2.initjmonopix2.conf 
  63   Sat Mar 15 09:51:23 2025 RD50 Generic UserAlignment Run 800MeV3Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux HighProtonUnknown9:4410:0319   RaMon Rate 2MHz

front sensors 200mu: ~50-100kHz
pro Streifen
  
  67   Sat Mar 15 15:02:39 2025 RD50 Generic UserRate testing7Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood15:0415:2521   RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false,
  
  73   Sat Mar 15 21:25:18 2025 RD50 Generic UserSlab Test Water 5cm14Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood21:2621:5014 Plastic Water Slabs5cmRaMon rate: 4.5MHz   
  74   Sat Mar 15 21:29:28 2025 RD50 Generic UserSlab and rate testing (with Michael)13Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood20:4421:2238 Plastic Water Slabs4cmtotzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
  
  75   Wed Mar 19 11:23:53 2025 bpjust testing            This is message text   
  76   Wed Mar 19 11:27:46 2025 bpjust testing            This is message text   
ELOG V3.1.5-fc6679b