ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_mindown Frontend Phantom Phantom thickness
  14   Fri Mar 14 21:54:32 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
about to get p+
  16   Fri Mar 14 22:13:14 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
APV25 latency 42 required for these input stretches
  19   Fri Mar 14 22:41:16 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
ignored veto of tracker
  21   Fri Mar 14 22:48:01 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
max trigger 75 -> 100
  23   Fri Mar 14 23:21:26 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
wrong trigger mode used for tracker
  24   Fri Mar 14 23:22:22 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
changed telescope timing again to latency 40
  25   Fri Mar 14 23:32:56 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
208 shows correlation
  33   Sat Mar 15 01:38:17 2025 elog-producerFast RO Test216TJ-Monopix2800 MeVLow Flux MediumProtonUnknown   HVNone 
Fast RO for Monopix:
W02W01 8b10b error quite early

Delay = 2
rd_frz_delay = 2

LOAD_CONF=10
FREEZE_STOP_CONF=11
STOP_CONF=10
  34   Sat Mar 15 01:51:31 2025 elog-producerFast RO Test TJ-Monopix2800 MeVLow Flux MediumProtonUnknown   HVNone 
Run 219, Medium settings, fast RO, W02R01 to 8b10b a few minutes in
  35   Sat Mar 15 01:58:29 2025 elog-producerFast RO Test TJ-Monopix2800 MeVLow Flux MediumProtonUnknown   HVNone 
Run 220, 8b10b error
  37   Sat Mar 15 02:34:31 2025 elog-producerFast RO Test TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
Run 223, 8b10b error again
  38   Sat Mar 15 02:46:47 2025 elog-producerenergy scans TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown   HVNone 
sticking with fast RO settings
  40   Sat Mar 15 02:56:07 2025 elog-producerenergy scans225TJ-Monopix2252.7 MeVLow Flux LowProtonUnknown   HVNone 
8b10b W02R01, 1 MHz rate (low flux low)
  41   Sat Mar 15 03:14:22 2025 elog-producerenergy scans226TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown   HVNone 
Run 226