Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-MA2018
testbeam-MA2019
testbeam-MA2020
testbeam-MA2021
testbeam-MA2023
testbeam-MA2024
testbeam-MA2025
Testbeams at MedAustron in 2025, Page 3 of 4
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
DSSD-Tracker
RD50-MPW4
TJ-Monopix2
TOF-Cal GSI
RaMon
TOF-Cal GSI \(TRB)+DOGMA setup\(diamond+LGAD)+RaMon
Sandwich-iCT setup\(GSI)+RaMon
-- Beam Energy --
800 MeV
252.7 MeV
194.3 MeV
175.3 MeV
145.4 MeV
100.4 MeV
83 MeV
62.4 MeV
115.7MeV
205.2 MeV/u
177.8 MeV/u
147.2 MeV/u
124.4 MeV/u
97.2MeV/u
73.2 MeV/u
63.3 MeV/u
402MeV/u
74 Entries
Goto page
Previous
1
,
2
, 3,
4
Next
All
ID
Date
Author
Subject
Run Number
DUT
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Frontend
Phantom
Phantom thickness
Text
69
Sat Mar 15 16:50:39 2025
RD50 Generic User
Slab Test Water 1cm
9
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
Good
16:35
17:23
48
Plastic Water Slabs
1cm
RaMon Rate: 1.3MHz
66
Sat Mar 15 13:15:25 2025
RD50 Generic User
Slab Measurement 205MeV
6
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
Good
13:27
14:49
82
RaMon Rate 1.3 MHz
Comments:
We entered the room and connected
65
Sat Mar 15 11:46:28 2025
RD50 Generic User
Slab Measurement 145MeV
5
Sandwich-iCT setup(GSI)+RaMon
145.4 MeV
Low Flux Medium
Proton
Good
11:48
13:13
85
RaMon Rate 600kHz
front sensors 200mu: ~1kHz pro
Streifen
67
Sat Mar 15 15:02:39 2025
RD50 Generic User
Rate testing
7
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux High
Helium
Good
15:04
15:25
21
RaMon Rate 4.5MHz
Comments:
From File 7 until 21 optional false,
68
Sat Mar 15 15:26:08 2025
RD50 Generic User
Rate testing
8
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
15:31
16:30
59
RaMon Rate: 1.3MHz
Comments:
Tested different evenbuilder settings
30
Sat Mar 15 01:05:30 2025
elog-producer
Fast RO Test
213
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
15.03.2025 00:50:36
15.03.2025 01:05:56
15
HV
None
automatic log for run 213
Comment:
Fast RO for Monopix:
31
Sat Mar 15 01:22:54 2025
elog-producer
Fast RO Test
214
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
15.03.2025 01:08:54
15.03.2025 01:23:21
14
HV
None
automatic log for run 214
Comment:
Fast RO for Monopix: Medium
32
Sat Mar 15 01:29:25 2025
elog-producer
Fast RO Test
215
TJ-Monopix2
800 MeV
Low Flux Low
Proton
Unknown
15.03.2025 01:26:13
15.03.2025 01:29:51
3
HV
None
automatic log for run 215
Comment:
Lower rates then Very low settings, so just
33
Sat Mar 15 01:38:17 2025
elog-producer
Fast RO Test
216
TJ-Monopix2
800 MeV
Low Flux Medium
Proton
Unknown
HV
None
Fast RO for Monopix:
W02W01 8b10b error quite early
34
Sat Mar 15 01:51:31 2025
elog-producer
Fast RO Test
TJ-Monopix2
800 MeV
Low Flux Medium
Proton
Unknown
HV
None
Run 219, Medium settings, fast RO, W02R01
to 8b10b a few minutes in
35
Sat Mar 15 01:58:29 2025
elog-producer
Fast RO Test
TJ-Monopix2
800 MeV
Low Flux Medium
Proton
Unknown
HV
None
Run 220, 8b10b error
36
Sat Mar 15 02:15:34 2025
elog-producer
Fast RO Test
221
TJ-Monopix2
800 MeV
Low Flux Low
Proton
Unknown
15.03.2025 02:02:15
15.03.2025 02:16:00
13
HV
None
automatic log for run 221
Comment:
37
Sat Mar 15 02:34:31 2025
elog-producer
Fast RO Test
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
HV
None
Run 223, 8b10b error again
61
Sat Mar 15 08:52:52 2025
RD50 Generic User
Alignment Run 800MeV
2
Sandwich-iCT setup(GSI)+RaMon
800 MeV
Low Flux Medium
Proton
Good
08:22
9:40
78
RaMon Rate 400kHz
front sensors 200mu: ~10-20kHz
pro Streifen
62
Sat Mar 15 08:58:26 2025
RD50 Generic User
Alignment Run 800MeV
1
Sandwich-iCT setup(GSI)+RaMon
800 MeV
Low Flux Low
Proton
Good
07:40
08:20
40
RaMon Rate not measured
front sensors 200mu: ~40-60Hz pro
Streifen
63
Sat Mar 15 09:51:23 2025
RD50 Generic User
Alignment Run 800MeV
3
Sandwich-iCT setup(GSI)+RaMon
800 MeV
Low Flux High
Proton
Unknown
9:44
10:03
19
RaMon Rate 2MHz
front sensors 200mu: ~50-100kHz
pro Streifen
64
Sat Mar 15 10:07:28 2025
RD50 Generic User
Alignment Run 252MeV
4
Sandwich-iCT setup(GSI)+RaMon
252.7 MeV
Low Flux Medium
Proton
Good
10:07
11:43
96
RaMon Rate 1MHz
front sensors 200mu: ~10-25kHz
pro Streifen
14
Fri Mar 14 21:54:32 2025
elog-producer
1st tests with beam
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
HV
None
about to get p+
15
Fri Mar 14 22:09:23 2025
elog-producer
1st tests with beam
200
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
14.03.2025 22:04:01
14.03.2025 22:09:49
5
HV
None
automatic log for run 200
Comment:
16
Fri Mar 14 22:13:14 2025
elog-producer
1st tests with beam
TJ-Monopix2
800 MeV
Low Flux Very Low
Proton
Unknown
HV
None
APV25 latency 42 required for these input
stretches
Goto page
Previous
1
,
2
, 3,
4
Next
All
ELOG V3.1.5-fc6679b