Entry  Sat Jun 21 21:33:45 2025, Julia Müllner, 124.4 MeV/u w 3slabs, 18, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, Good, 21:34, 21:47, 13, , PTW Slabs, 3cm 
 
Entry  Sat Jun 21 21:11:04 2025, Julia Müllner, 124.4 MeV/u w 2slabs, 17, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, Good, 21:16, 21:29, 13, , PTW Slabs, 2cm 
 
Entry  Sat Jun 21 20:42:42 2025, Julia Müllner, 124.4 MeV/u w slabs, 16, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, Good, 21:01, 21:10, 9, , PTW Slabs, 1cm 

1.041 WET RW3 (mm)

Entry  Sat Jun 21 20:32:58 2025, Julia Müllner, 402MeV systemtest , 15, TOF-Cal GSI, 402MeV/u, Low Flux High, Helium, Good, 20:35, 20:47, 12, , ,  

rejected roughly 10-20%, 8MHz beam

rejected quite a lot of data later -> eventloader restarted

Entry  Sat Jun 21 20:24:05 2025, Julia Müllner, 205.2 MeV systemtest , 14, TOF-Cal GSI, 205.2 MeV/u, Low Flux High, Helium, Good, 20:24, 20:32, 8, , ,  

last events already with 400MeV/u

Entry  Sat Jun 21 20:15:25 2025, Julia Müllner, 177.8 MeV systemtest , 13, TOF-Cal GSI, 177.8 MeV/u, Low Flux High, Helium, Good, 20:16, 20:23, 7, , ,  

16.2 GB collected

Entry  Sat Jun 21 20:05:49 2025, Julia Müllner, 147.2 MeV systemtest , 12, TOF-Cal GSI, 147.2 MeV/u, Low Flux High, Helium, Good, 20:06, 20:15, 9, , ,  
 
Entry  Sat Jun 21 19:54:12 2025, Julia Müllner, 124.4 MeV systemtest , 11, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, Good, 19:54, 20:05, 11, , ,  

16GB collected

Entry  Sat Jun 21 19:35:59 2025, Julia Müllner, 63.3 MeV systemtest , 10, TOF-Cal GSI, 63.3 MeV/u, Low Flux High, Helium, Good, 19:37, 19:53, 16, , ,  
 
Entry  Sat Jun 21 19:22:45 2025, Julia Müllner, 73.2 MeV systemtest , 9, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Good, 19:23, 19:35, 12, , ,  

Threshold change from 50 to 500

10GB collected

Entry  Sat Jun 21 18:22:28 2025, Julia Müllner, 73.2 MeV systemtest , 8, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Crap, 19:10, 19:21, 11, , ,  

new callibration was done, dimanond detector connected to readout

Threshold = 4000

thresholds were too low -> run was canceled

Entry  Sat Jun 21 18:05:21 2025, Julia Müllner, 97.2 MeV systemtest , 7, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 18:06, 18:21, 15, , ,  

Threshold set to 2000

50GB data collected

Room Entry Request: 18:21

Entry  Sat Jun 21 17:54:27 2025, Julia Müllner, 97.2 MeV systemtest , 6, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:56, 18:04, 8, , ,  

Threshold set to 4000

40GB data collected

Entry  Sat Jun 21 17:13:34 2025, Julia Müllner, 97.2 MeV systemtest , 5, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:31, 17:54, 23, , ,  

Threshold set to 3000

moved Ripple filters back in 

100GB data collected

Entry  Sat Jun 21 17:01:05 2025, Julia Müllner, 97.2 MeV systemtest , 4, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 16:58, 17:11, 13, , ,  

Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12.

Entry  Sat Jun 21 16:30:44 2025, Julia Müllner, 205.2 MeV systemtest , 3, TOF-Cal GSI, 205.2 MeV/u, Low Flux High, Helium, Unknown, 16:38, 16:57, 19, , ,  

Threshold set to 5000

dead channels on last LGAD, changed trigger from LGAD 12 to LGAD 11

Entry  Sat Jun 21 15:43:47 2025, Julia Müllner, 800MeV systemtest , 2, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 16:02, 16:29, 27, , ,  

Threshold set to 1000

Factor 4 chosen for future runs, 80 GB in total recorded in this run

Entry  Sat Jun 21 14:30:29 2025, Julia Müllner, 800MeV systemtest , 1, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 14:45, 15:42, 57, , ,  

first spills were done with low flux medium, changed to high at 14:49

again changed to medium at 14:55

again changed to high at 15:00

30 MB pro event builder

last few spills were with the wrong threshold

thresholds were set to 2000 instead of 1000 

Entry  Sat Mar 15 21:29:28 2025, RD50 Generic User, Slab and rate testing (with Michael), 13, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 20:44, 21:22, 38, , Plastic Water Slabs, 4cm 

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600

Entry  Sat Mar 15 21:25:18 2025, RD50 Generic User, Slab Test Water 5cm, 14, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 21:26, 21:50, 24, , Plastic Water Slabs, 5cm 

RaMon rate: 4.5MHz