  69   Sat Mar 15 16:50:39 2025 RD50 Generic UserSlab Test Water 1cm9Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood16:3517:2348 Plastic Water Slabs1cm

RaMon Rate: 1.3MHz

  66   Sat Mar 15 13:15:25 2025 RD50 Generic UserSlab Measurement 205MeV6Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood13:2714:4982   

RaMon Rate 1.3 MHz

Comments:

We entered the room and connected the second LAN Port to the ReadOut-PC. The Eventbuilder-parameter got changed.

  65   Sat Mar 15 11:46:28 2025 RD50 Generic UserSlab Measurement 145MeV5Sandwich-iCT setup(GSI)+RaMon145.4 MeVLow Flux MediumProtonGood11:4813:1385   

RaMon Rate 600kHz

front sensors 200mu: ~1kHz pro Streifen

Comments:

change of the trigger settings inbetween, we saw inefficency on all detectors

  67   Sat Mar 15 15:02:39 2025 RD50 Generic UserRate testing7Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood15:0415:2521   

RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)

  68   Sat Mar 15 15:26:08 2025 RD50 Generic UserRate testing8Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 15:3116:3059   

RaMon Rate: 1.3MHz

Comments:

Tested different evenbuilder settings which made things worse, probably switch is the bottleneck, changed rate settings inbetween, requires sergey

  30   Sat Mar 15 01:05:30 2025 elog-producerFast RO Test213TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown15.03.2025 00:50:3615.03.2025 01:05:5615HVNone 
automatic log for run 213
Comment:
Fast RO for Monopix:

Delay = 2
rd_frz_delay = 2

LOAD_CONF=10
FREEZE_STOP_CONF=11
STOP_CONF=10
  31   Sat Mar 15 01:22:54 2025 elog-producerFast RO Test214TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown15.03.2025 01:08:5415.03.2025 01:23:2114HVNone 
automatic log for run 214
Comment:
Fast RO for Monopix: Medium

Delay = 20
rd_frz_delay = 20

LOAD_CONF=20
FREEZE_STOP_CONF=21
STOP_CONF=20
  32   Sat Mar 15 01:29:25 2025 elog-producerFast RO Test215TJ-Monopix2800 MeVLow Flux LowProtonUnknown15.03.2025 01:26:1315.03.2025 01:29:513HVNone 
automatic log for run 215
Comment:
Lower rates then Very low settings, so just a quick run here
Fast RO for Monopix:

Delay = 2
rd_frz_delay = 2

LOAD_CONF=10
FREEZE_STOP_CONF=11
STOP_CONF=10
  33   Sat Mar 15 01:38:17 2025 elog-producerFast RO Test216TJ-Monopix2800 MeVLow Flux MediumProtonUnknown   HVNone 
Fast RO for Monopix:
W02W01 8b10b error quite early

Delay = 2
rd_frz_delay = 2

LOAD_CONF=10
FREEZE_STOP_CONF=11
STOP_CONF=10
  34   Sat Mar 15 01:51:31 2025 elog-producerFast RO Test TJ-Monopix2800 MeVLow Flux MediumProtonUnknown   HVNone 
Run 219, Medium settings, fast RO, W02R01 to 8b10b a few minutes in
  35   Sat Mar 15 01:58:29 2025 elog-producerFast RO Test TJ-Monopix2800 MeVLow Flux MediumProtonUnknown   HVNone 
Run 220, 8b10b error
  36   Sat Mar 15 02:15:34 2025 elog-producerFast RO Test221TJ-Monopix2800 MeVLow Flux LowProtonUnknown15.03.2025 02:02:1515.03.2025 02:16:0013HVNone 
automatic log for run 221
Comment:
  37   Sat Mar 15 02:34:31 2025 elog-producerFast RO Test TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
Run 223, 8b10b error again
  61   Sat Mar 15 08:52:52 2025 RD50 Generic UserAlignment Run 800MeV2Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux MediumProtonGood08:229:4078   

RaMon Rate 400kHz

front sensors 200mu: ~10-20kHz pro Streifen

Comments:

In between run, sensors were shifted by 2mm to the left (left and right in online DAQ is mirrored)

 

  62   Sat Mar 15 08:58:26 2025 RD50 Generic UserAlignment Run 800MeV1Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux LowProtonGood07:4008:2040   

RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro Streifen

Comments:

stopped run due to too low rate

 

  63   Sat Mar 15 09:51:23 2025 RD50 Generic UserAlignment Run 800MeV3Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux HighProtonUnknown9:4410:0319   

RaMon Rate 2MHz

front sensors 200mu: ~50-100kHz pro Streifen

Comments:

Factor 10 lost more data than measured

 

  64   Sat Mar 15 10:07:28 2025 RD50 Generic UserAlignment Run 252MeV4Sandwich-iCT setup(GSI)+RaMon252.7 MeVLow Flux MediumProtonGood10:0711:4396   

RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen

  14   Fri Mar 14 21:54:32 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
about to get p+
  15   Fri Mar 14 22:09:23 2025 elog-producer1st tests with beam200TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 22:04:0114.03.2025 22:09:495HVNone 
automatic log for run 200
Comment:
  16   Fri Mar 14 22:13:14 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
APV25 latency 42 required for these input stretches