  Testbeams at MedAustron in 2025, Page 3 of 4  Not logged in ELOG logo
ID Date Author Subject Run Numberdown DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  22   Fri Mar 14 23:21:11 2025 elog-producer1st tests with beam208TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 23:19:4714.03.2025 23:21:371HVNone 
automatic log for run 208
Comment:
  20   Fri Mar 14 22:47:46 2025 elog-producer1st tests with beam203TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 22:42:3014.03.2025 22:48:125HVNone 
automatic log for run 203
Comment:
  18   Fri Mar 14 22:41:04 2025 elog-producer1st tests with beam202TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 22:38:5114.03.2025 22:41:302HVNone 
automatic log for run 202
Comment:
  17   Fri Mar 14 22:20:25 2025 elog-producer1st tests with beam201TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 22:11:2314.03.2025 22:20:519HVNone 
automatic log for run 201
Comment:
  15   Fri Mar 14 22:09:23 2025 elog-producer1st tests with beam200TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 22:04:0114.03.2025 22:09:495HVNone 
automatic log for run 200
Comment:
  61   Sat Mar 15 08:52:52 2025 RD50 Generic UserAlignment Run 800MeV2Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux MediumProtonGood08:229:4078   

RaMon Rate 400kHz

front sensors 200mu: ~10-20kHz pro Streifen

Comments:

In between run, sensors were shifted by 2mm to the left (left and right in online DAQ is mirrored)

 

  73   Sat Mar 15 21:25:18 2025 RD50 Generic UserSlab Test Water 5cm14Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood21:2621:5024 Plastic Water Slabs5cm

RaMon rate: 4.5MHz

  74   Sat Mar 15 21:29:28 2025 RD50 Generic UserSlab and rate testing (with Michael)13Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood20:4421:2238 Plastic Water Slabs4cm

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600

  72   Sat Mar 15 19:37:42 2025 RD50 Generic UserSlab Test Water 4cm12Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 19:3920:4162 Plastic Water Slabs4cm

RaMon Rate 1.4MHz

  12   Fri Mar 14 21:44:46 2025 elog-producervalidating setup118TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 21:44:2014.03.2025 21:45:120HVNone 
automatic log for run 118
Comment:
tracker test without beam
  11   Fri Mar 14 21:43:10 2025 elog-producervalidating setup117TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 21:42:4614.03.2025 21:43:360HVNone 
automatic log for run 117
Comment:
tracker test without beam
  10   Fri Mar 14 21:41:12 2025 elog-producervalidating setup116TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 21:41:0514.03.2025 21:41:380HVNone 
automatic log for run 116
Comment:
tracker test without beam
  8   Fri Mar 14 20:40:06 2025 elog-producervalidating setup112TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 20:07:4714.03.2025 20:40:3232HVNone 
automatic log for run 112
Comment:
still testing nonsense
  7   Fri Mar 14 20:04:41 2025 elog-producervalidating setup111TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 20:03:3414.03.2025 20:05:071HVNone 
automatic log for run 111
Comment:
bla
  6   Fri Mar 14 19:57:28 2025 elog-producervalidating setup110TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 19:51:5114.03.2025 19:57:546HVNone 
automatic log for run 110
Comment:
bla
  71   Sat Mar 15 18:37:36 2025 RD50 Generic UserSlab Test Water 3cm11Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 18:4119:2847 Plastic Water Slabs3cm

RaMon Rate 1.5MHz

  5   Fri Mar 14 19:50:29 2025 elog-producervalidating setup109TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown14.03.2025 19:49:1014.03.2025 19:50:551HVNone 
automatic log for run 109
Comment:
system tests
  70   Sat Mar 15 17:30:18 2025 RD50 Generic UserSlab Test Water 2cm10Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 17:3018:2454 Plastic Water Slabs2cm

RaMon Rate 1.5 MHz

  62   Sat Mar 15 08:58:26 2025 RD50 Generic UserAlignment Run 800MeV1Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux LowProtonGood07:4008:2040   

RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro Streifen

Comments:

stopped run due to too low rate

 

  1   Wed Mar 12 09:29:08 2025 tb-crewvalidating setup TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
1st test