Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 1 of 4  Not logged in ELOG logo
Entry  Wed Mar 19 11:27:46 2025, bp, just testing, , , , , , , , , , , ,  
This is message text
Entry  Wed Mar 19 11:23:53 2025, bp, just testing, , , , , , , , , , , ,  
This is message text
Entry  Sat Mar 15 21:29:28 2025, RD50 Generic User, Slab and rate testing (with Michael), 13, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 20:44, 21:22, 38, , Plastic Water Slabs, 4cm 

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600

Entry  Sat Mar 15 21:25:18 2025, RD50 Generic User, Slab Test Water 5cm, 14, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 21:26, 21:50, 14, , Plastic Water Slabs, 5cm 

RaMon rate: 4.5MHz

Entry  Sat Mar 15 19:37:42 2025, RD50 Generic User, Slab Test Water 4cm, 12, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 19:39, 20:41, 62, , Plastic Water Slabs, 4cm 

RaMon Rate 1.4MHz

Entry  Sat Mar 15 18:37:36 2025, RD50 Generic User, Slab Test Water 3cm, 11, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 18:41, 19:28, 47, , Plastic Water Slabs, 3cm 

RaMon Rate 1.5MHz

Entry  Sat Mar 15 17:30:18 2025, RD50 Generic User, Slab Test Water 2cm, 10, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 17:30, 18:24, 54, , Plastic Water Slabs, 2cm 

RaMon Rate 1.5 MHz

Entry  Sat Mar 15 16:50:39 2025, RD50 Generic User, Slab Test Water 1cm, 9, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 16:35, 17:23, 48, , Plastic Water Slabs, 1cm 

RaMon Rate: 1.3MHz

Entry  Sat Mar 15 15:26:08 2025, RD50 Generic User, Rate testing, 8, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 15:31, 16:30, 59, , ,  

RaMon Rate: 1.3MHz

Comments:

Tested different evenbuilder settings which made things worse, probably switch is the bottleneck, changed rate settings inbetween, requires sergey

Entry  Sat Mar 15 15:02:39 2025, RD50 Generic User, Rate testing, 7, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 15:04, 15:25, 21, , ,  

RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)

Entry  Sat Mar 15 13:15:25 2025, RD50 Generic User, Slab Measurement 205MeV, 6, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 13:27, 14:49, 82, , ,  

RaMon Rate 1.3 MHz

Comments:

We entered the room and connected the second LAN Port to the ReadOut-PC. The Eventbuilder-parameter got changed.

Entry  Sat Mar 15 11:46:28 2025, RD50 Generic User, Slab Measurement 145MeV, 5, Sandwich-iCT setup(GSI)+RaMon, 145.4 MeV, Low Flux Medium, Proton, Good, 11:48, 13:13, 85, , ,  

RaMon Rate 600kHz

front sensors 200mu: ~1kHz pro Streifen

Comments:

change of the trigger settings inbetween, we saw inefficency on all detectors

Entry  Sat Mar 15 10:07:28 2025, RD50 Generic User, Alignment Run 252MeV, 4, Sandwich-iCT setup(GSI)+RaMon, 252.7 MeV, Low Flux Medium, Proton, Good, 10:07, 11:43, 96, , ,  

RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen

Entry  Sat Mar 15 09:51:23 2025, RD50 Generic User, Alignment Run 800MeV, 3, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux High, Proton, Unknown, 9:44, 10:03, 19, , ,  

RaMon Rate 2MHz

front sensors 200mu: ~50-100kHz pro Streifen

Comments:

Factor 10 lost more data than measured

 

Entry  Sat Mar 15 08:58:26 2025, RD50 Generic User, Alignment Run 800MeV, 1, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Low, Proton, Good, 07:40, 08:20, 40, , ,  

RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro Streifen

Comments:

stopped run due to too low rate

 

Entry  Sat Mar 15 08:52:52 2025, RD50 Generic User, Alignment Run 800MeV, 2, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Medium, Proton, Good, 08:22, 9:40, 78, , ,  

RaMon Rate 400kHz

front sensors 200mu: ~10-20kHz pro Streifen

Comments:

In between run, sensors were shifted by 2mm to the left (left and right in online DAQ is mirrored)

 

Entry  Sat Mar 15 05:42:14 2025, elog-producer, test 8b10b, 246, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 15.03.2025 05:38:42, 15.03.2025 05:42:41, 3, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 246
Comment:
BDAQ Board to Monopix connection swapped - and now the W02R01 chip works fine with full rate
Entry  Sat Mar 15 05:27:08 2025, elog-producer, test 8b10b, 245, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 15.03.2025 05:26:52, 15.03.2025 05:27:34, 0, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 245
Comment:
test with swapped ethernet ports and bsaq IP adresses
Entry  Sat Mar 15 05:12:19 2025, elog-producer, test 8b10b, 244, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 15.03.2025 05:08:03, 15.03.2025 05:12:46, 4, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 244
Comment:
both chips, more stat with small window on W02R01
Entry  Sat Mar 15 05:06:44 2025, elog-producer, test 8b10b, 243, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 15.03.2025 05:05:59, 15.03.2025 05:07:10, 1, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 243
Comment:
ELOG V3.1.5-fc6679b