Tue Aug 5 14:43:42 2025, elog_producer, Castid, , TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Crap, , , , HV, None,
|
| test |
Tue Aug 5 16:02:12 2025, elog_producer, Castid, , TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Crap, , , , HV, None,
|
| manual test |
Tue Aug 5 16:12:07 2025, elog_producer, Castid, , TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Crap, , , , HV, None,
|
| Test debugging tests for debugging to test debugging |
Sat Aug 16 23:44:00 2025, Maximilian Babeluk, CASTID - Summary, , TJ-Monopix2, 800 MeV, , Proton, , , , , , ,
|
Summary for the CASTID shift RO Aug 16, 2025
We measured four TJ-Monopix2 DUTS with HV/HVC frontends using AIDA mode in a stacked telescope configuration. We used 800MeV protons at low flux settings from very low to high.
We took two high statistics runs on each of the 4 rates. Then we repeated the measurements at medium and high settings for following readout speeds (40 is the default): 30, 20, 10, 2 (minimum).
At increased readout speed, we shoudl be able to recover (part) of the efficiency drop at increased rates.
- Occasionally (maybe a few times an hour but in clusters) we got 8b/10b errors. If so, they all came from the W02R01 DUT using BDAQ board #063/50 and the TLU adapter 1. This is the main source of having 'crap' data
- About 3 times during the test beam, one of the chips (each time a different one) stopped sending data which was possible to recover with a power cycle.
|
Sat Sep 20 16:49:03 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, , , , Normal, ,
|
| tracker debugging |
Sat Sep 20 17:20:34 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, , , , Normal, ,
|
| tracker storing files, path was wrong |
Sat Sep 20 17:28:07 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, , , , Normal, ,
|
| debugging mpw4, config problems |
Sat Sep 20 17:50:13 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, , , , Normal, ,
|
| hunting for Correlations |
Sat Sep 20 17:53:53 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, , , , Normal, ,
|
| Correlations found in 1013 |
Sat Sep 20 18:10:06 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Unknown, , , , Normal, ,
|
| changing rate |
Sat Sep 20 19:55:38 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Unknown, , , , Normal, ,
|
| bias voltage scan shows top/ -backside diff expectations |
Sat Sep 20 19:55:54 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Unknown, , , , Normal, ,
|
| bias voltage scan going for low voltages now |
Sat Sep 20 20:18:40 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Unknown, , , , Normal, ,
|
| going for higher rates |
Sat Sep 20 20:33:23 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,
|
| high rate now |
Sat Sep 20 20:40:49 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,
|
| data collector starts to loose frames |
Sat Sep 20 20:41:39 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,
|
| data collector starts to loose frames |
Sat Sep 20 20:59:07 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,
|
| lost one right at the end 20:58:44 |
Sat Sep 20 21:00:14 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,
|
| changing Peary readout to DMA |
Sat Sep 20 21:00:20 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,
|
| changing Peary readout to DMA |
Sat Sep 20 21:19:04 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,
|
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now |
|