  242   Sat Sep 20 21:00:20 2025 elog_producerCaribou 1.5 RD50-MPW4800 MeVLow Flux HighProtonUnknown   Normal  
changing Peary readout to DMA
  243   Sat Sep 20 21:02:14 2025 elog_producerCaribou 1.51041RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:01:3420.09.2025 21:02:260Normal  
automatic log for run 1041
Comment:
no data from DMA Frown
  244   Sat Sep 20 21:12:30 2025 elog_producerCaribou 1.51042RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:11:5720.09.2025 21:12:410Normal  
automatic log for run 1042
Comment:
DMA debugging
  245   Sat Sep 20 21:19:04 2025 elog_producerCaribou 1.5 RD50-MPW4800 MeVLow Flux HighProtonUnknown   Normal  
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
  246   Sat Sep 20 21:19:29 2025 elog_producerCaribou 1.51043RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:18:0920.09.2025 21:19:401Normal  
automatic log for run 1043
Comment:
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
  247   Sat Sep 20 21:23:52 2025 elog_producerCaribou 1.51044RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:23:4420.09.2025 21:24:030Normal  
automatic log for run 1044
Comment:
DMA debugging
no data
  197   Sat Aug 16 23:44:00 2025 Maximilian BabelukCASTID - Summary TJ-Monopix2800 MeV Proton       

Summary for the CASTID shift RO Aug 16, 2025

We measured four TJ-Monopix2 DUTS with HV/HVC frontends using AIDA mode in a stacked telescope configuration. We used 800MeV protons at low flux settings from very low to high.

 

We took two high statistics runs on each of the 4 rates. Then we repeated the measurements at medium and high settings for following readout speeds (40 is the default): 30, 20, 10, 2 (minimum).

At increased readout speed, we shoudl be able to recover (part) of the efficiency drop at increased rates.

- Occasionally (maybe a few times an hour but in clusters) we got 8b/10b errors. If so, they all came from the W02R01 DUT using BDAQ board #063/50 and the TLU adapter 1. This is the main source of having 'crap' data

- About 3 times during the test beam, one of the chips (each time a different one) stopped sending data which was possible to recover with a power cycle.

 