Entry  Sat Sep 20 20:32:10 2025, elog_producer, Caribou 1.5, 1037, RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Unknown, 20.09.2025 20:27:14, 20.09.2025 20:32:22, 5, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1037
Comment:
higher rates
Entry  Sat Sep 20 20:33:23 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,  
high rate now
Entry  Sat Sep 20 20:40:06 2025, elog_producer, Caribou 1.5, 1038, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 20:34:31, 20.09.2025 20:40:18, 5, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1038
Comment:
Entry  Sat Sep 20 20:40:49 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,  
data collector starts to loose frames
Entry  Sat Sep 20 20:41:39 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,  
data collector starts to loose frames
Entry  Sat Sep 20 20:58:41 2025, elog_producer, Caribou 1.5, 1040, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 20:51:57, 20.09.2025 20:58:53, 6, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1040
Comment:
this time no RX drops
Entry  Sat Sep 20 20:59:07 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,  
lost one right at the end 20:58:44
Entry  Sat Sep 20 21:00:14 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,  
changing Peary readout to DMA
Entry  Sat Sep 20 21:00:20 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,  
changing Peary readout to DMA
Entry  Sat Sep 20 21:02:14 2025, elog_producer, Caribou 1.5, 1041, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:01:34, 20.09.2025 21:02:26, 0, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1041
Comment:
no data from DMA Frown
Entry  Sat Sep 20 21:12:30 2025, elog_producer, Caribou 1.5, 1042, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:11:57, 20.09.2025 21:12:41, 0, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1042
Comment:
DMA debugging
Entry  Sat Sep 20 21:19:04 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,  
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
Entry  Sat Sep 20 21:19:29 2025, elog_producer, Caribou 1.5, 1043, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:18:09, 20.09.2025 21:19:40, 1, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1043
Comment:
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
Entry  Sat Sep 20 21:23:52 2025, elog_producer, Caribou 1.5, 1044, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:23:44, 20.09.2025 21:24:03, 0, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1044
Comment:
DMA debugging
no data
Entry  Sat Aug 16 23:44:00 2025, Maximilian Babeluk, CASTID - Summary, , TJ-Monopix2, 800 MeV, , Proton, , , , , , ,  

Summary for the CASTID shift RO Aug 16, 2025

We measured four TJ-Monopix2 DUTS with HV/HVC frontends using AIDA mode in a stacked telescope configuration. We used 800MeV protons at low flux settings from very low to high.

 

We took two high statistics runs on each of the 4 rates. Then we repeated the measurements at medium and high settings for following readout speeds (40 is the default): 30, 20, 10, 2 (minimum).

At increased readout speed, we shoudl be able to recover (part) of the efficiency drop at increased rates.

- Occasionally (maybe a few times an hour but in clusters) we got 8b/10b errors. If so, they all came from the W02R01 DUT using BDAQ board #063/50 and the TLU adapter 1. This is the main source of having 'crap' data

- About 3 times during the test beam, one of the chips (each time a different one) stopped sending data which was possible to recover with a power cycle.

 

Entry  Sat Mar 15 08:52:52 2025, RD50 Generic User, Alignment Run 800MeV, 2, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Medium, Proton, Good, 08:22, 9:40, 78, , ,  

RaMon Rate 400kHz

front sensors 200mu: ~10-20kHz pro Streifen

Comments:

In between run, sensors were shifted by 2mm to the left (left and right in online DAQ is mirrored)

 

Entry  Sat Mar 15 08:58:26 2025, RD50 Generic User, Alignment Run 800MeV, 1, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Low, Proton, Good, 07:40, 08:20, 40, , ,  

RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro Streifen

Comments:

stopped run due to too low rate

 

Entry  Sat Mar 15 09:51:23 2025, RD50 Generic User, Alignment Run 800MeV, 3, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux High, Proton, Unknown, 9:44, 10:03, 19, , ,  

RaMon Rate 2MHz

front sensors 200mu: ~50-100kHz pro Streifen

Comments:

Factor 10 lost more data than measured

 

Entry  Sat Mar 15 10:07:28 2025, RD50 Generic User, Alignment Run 252MeV, 4, Sandwich-iCT setup(GSI)+RaMon, 252.7 MeV, Low Flux Medium, Proton, Good, 10:07, 11:43, 96, , ,  

RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen

Entry  Sat Dec 13 08:06:08 2025, elog_producer, Alignment, 2, TOF-Cal_GSI_8LGAD+RaMon, 200 MeV/u, Low Flux High, , Good, 13.12.2025 07:56:31, 13.12.2025 08:06:34, 10, Normal, None,  ramon.conf
automatic log for run 2
Comment:
initial alignment run
(run 1 not recorded, same settings)