Entry  Sat Mar 15 15:02:39 2025, RD50 Generic User, Rate testing, 7, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 15:04, 15:25, 21, , ,  

RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)

Entry  Sat Mar 15 15:26:08 2025, RD50 Generic User, Rate testing, 8, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 15:31, 16:30, 59, , ,  

RaMon Rate: 1.3MHz

Comments:

Tested different evenbuilder settings which made things worse, probably switch is the bottleneck, changed rate settings inbetween, requires sergey

Entry  Sat Mar 15 16:50:39 2025, RD50 Generic User, Slab Test Water 1cm, 9, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 16:35, 17:23, 48, , Plastic Water Slabs, 1cm 

RaMon Rate: 1.3MHz

Entry  Sat Mar 15 17:30:18 2025, RD50 Generic User, Slab Test Water 2cm, 10, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 17:30, 18:24, 54, , Plastic Water Slabs, 2cm 

RaMon Rate 1.5 MHz

Entry  Sat Mar 15 18:37:36 2025, RD50 Generic User, Slab Test Water 3cm, 11, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 18:41, 19:28, 47, , Plastic Water Slabs, 3cm 

RaMon Rate 1.5MHz

Entry  Sat Mar 15 19:37:42 2025, RD50 Generic User, Slab Test Water 4cm, 12, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 19:39, 20:41, 62, , Plastic Water Slabs, 4cm 

RaMon Rate 1.4MHz

Entry  Sat Mar 15 21:25:18 2025, RD50 Generic User, Slab Test Water 5cm, 14, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 21:26, 21:50, 24, , Plastic Water Slabs, 5cm 

RaMon rate: 4.5MHz

Entry  Sat Mar 15 21:29:28 2025, RD50 Generic User, Slab and rate testing (with Michael), 13, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 20:44, 21:22, 38, , Plastic Water Slabs, 4cm 

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600

Entry  Sat Aug 16 23:44:00 2025, Maximilian Babeluk, CASTID - Summary, , TJ-Monopix2, 800 MeV, , Proton, , , , , , ,  

Summary for the CASTID shift RO Aug 16, 2025

We measured four TJ-Monopix2 DUTS with HV/HVC frontends using AIDA mode in a stacked telescope configuration. We used 800MeV protons at low flux settings from very low to high.

 

We took two high statistics runs on each of the 4 rates. Then we repeated the measurements at medium and high settings for following readout speeds (40 is the default): 30, 20, 10, 2 (minimum).

At increased readout speed, we shoudl be able to recover (part) of the efficiency drop at increased rates.

- Occasionally (maybe a few times an hour but in clusters) we got 8b/10b errors. If so, they all came from the W02R01 DUT using BDAQ board #063/50 and the TLU adapter 1. This is the main source of having 'crap' data

- About 3 times during the test beam, one of the chips (each time a different one) stopped sending data which was possible to recover with a power cycle.

 

Entry  Sat Jun 21 14:30:29 2025, Julia Müllner, 800MeV systemtest , 1, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 14:45, 15:42, 57, , ,  

first spills were done with low flux medium, changed to high at 14:49

again changed to medium at 14:55

again changed to high at 15:00

30 MB pro event builder

last few spills were with the wrong threshold

thresholds were set to 2000 instead of 1000 

Entry  Sat Jun 21 15:43:47 2025, Julia Müllner, 800MeV systemtest , 2, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 16:02, 16:29, 27, , ,  

Threshold set to 1000

Factor 4 chosen for future runs, 80 GB in total recorded in this run

Entry  Sat Jun 21 16:30:44 2025, Julia Müllner, 205.2 MeV systemtest , 3, TOF-Cal GSI, 205.2 MeV/u, Low Flux High, Helium, Unknown, 16:38, 16:57, 19, , ,  

Threshold set to 5000

dead channels on last LGAD, changed trigger from LGAD 12 to LGAD 11

Entry  Sat Jun 21 17:01:05 2025, Julia Müllner, 97.2 MeV systemtest , 4, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 16:58, 17:11, 13, , ,  

Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12.

Entry  Sat Jun 21 17:13:34 2025, Julia Müllner, 97.2 MeV systemtest , 5, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:31, 17:54, 23, , ,  

Threshold set to 3000

moved Ripple filters back in 

100GB data collected

Entry  Sat Jun 21 17:54:27 2025, Julia Müllner, 97.2 MeV systemtest , 6, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:56, 18:04, 8, , ,  

Threshold set to 4000

40GB data collected

Entry  Sat Jun 21 18:05:21 2025, Julia Müllner, 97.2 MeV systemtest , 7, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 18:06, 18:21, 15, , ,  

Threshold set to 2000

50GB data collected

Room Entry Request: 18:21

Entry  Sat Jun 21 18:22:28 2025, Julia Müllner, 73.2 MeV systemtest , 8, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Crap, 19:10, 19:21, 11, , ,  

new callibration was done, dimanond detector connected to readout

Threshold = 4000

thresholds were too low -> run was canceled

Entry  Sat Jun 21 19:22:45 2025, Julia Müllner, 73.2 MeV systemtest , 9, TOF-Cal GSI, 73.2 MeV/u, Low Flux High, Helium, Good, 19:23, 19:35, 12, , ,  

Threshold change from 50 to 500

10GB collected

Entry  Sat Jun 21 19:35:59 2025, Julia Müllner, 63.3 MeV systemtest , 10, TOF-Cal GSI, 63.3 MeV/u, Low Flux High, Helium, Good, 19:37, 19:53, 16, , ,  
 
Entry  Sat Jun 21 19:54:12 2025, Julia Müllner, 124.4 MeV systemtest , 11, TOF-Cal GSI, 124.4 MeV/u, Low Flux High, Helium, Good, 19:54, 20:05, 11, , ,  

16GB collected