Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 10 of 10  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_mindown Frontend Phantom Phantom thickness
  16   Fri Mar 14 22:13:14 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
APV25 latency 42 required for these input stretches
  19   Fri Mar 14 22:41:16 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
ignored veto of tracker
  21   Fri Mar 14 22:48:01 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
max trigger 75 -> 100
  23   Fri Mar 14 23:21:26 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
wrong trigger mode used for tracker
  24   Fri Mar 14 23:22:22 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
changed telescope timing again to latency 40
  25   Fri Mar 14 23:32:56 2025 elog-producer1st tests with beam TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
208 shows correlation
  33   Sat Mar 15 01:38:17 2025 elog-producerFast RO Test216TJ-Monopix2800 MeVLow Flux MediumProtonUnknown   HVNone 
Fast RO for Monopix:
W02W01 8b10b error quite early

Delay = 2
rd_frz_delay = 2

LOAD_CONF=10
FREEZE_STOP_CONF=11
STOP_CONF=10
  34   Sat Mar 15 01:51:31 2025 elog-producerFast RO Test TJ-Monopix2800 MeVLow Flux MediumProtonUnknown   HVNone 
Run 219, Medium settings, fast RO, W02R01 to 8b10b a few minutes in
  35   Sat Mar 15 01:58:29 2025 elog-producerFast RO Test TJ-Monopix2800 MeVLow Flux MediumProtonUnknown   HVNone 
Run 220, 8b10b error
  37   Sat Mar 15 02:34:31 2025 elog-producerFast RO Test TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
Run 223, 8b10b error again
  38   Sat Mar 15 02:46:47 2025 elog-producerenergy scans TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown   HVNone 
sticking with fast RO settings
  40   Sat Mar 15 02:56:07 2025 elog-producerenergy scans225TJ-Monopix2252.7 MeVLow Flux LowProtonUnknown   HVNone 
8b10b W02R01, 1 MHz rate (low flux low)
  41   Sat Mar 15 03:14:22 2025 elog-producerenergy scans226TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown   HVNone 
Run 226
  133   Tue Aug 5 14:43:42 2025 elog_producerCastid TJ-Monopix2800 MeVLow Flux MediumProtonCrap   HVNone 
test
  134   Tue Aug 5 16:02:12 2025 elog_producerCastid TJ-Monopix2800 MeVLow Flux MediumProtonCrap   HVNone 
manual test
  136   Tue Aug 5 16:12:07 2025 elog_producerCastid TJ-Monopix2800 MeVLow Flux MediumProtonCrap   HVNone 
Test debugging tests for debugging to test debugging
  197   Sat Aug 16 23:44:00 2025 Maximilian BabelukCASTID - Summary TJ-Monopix2800 MeV Proton       

Summary for the CASTID shift RO Aug 16, 2025

We measured four TJ-Monopix2 DUTS with HV/HVC frontends using AIDA mode in a stacked telescope configuration. We used 800MeV protons at low flux settings from very low to high.

 

We took two high statistics runs on each of the 4 rates. Then we repeated the measurements at medium and high settings for following readout speeds (40 is the default): 30, 20, 10, 2 (minimum).

At increased readout speed, we shoudl be able to recover (part) of the efficiency drop at increased rates.

- Occasionally (maybe a few times an hour but in clusters) we got 8b/10b errors. If so, they all came from the W02R01 DUT using BDAQ board #063/50 and the TLU adapter 1. This is the main source of having 'crap' data

- About 3 times during the test beam, one of the chips (each time a different one) stopped sending data which was possible to recover with a power cycle.

 

ELOG V3.1.5-fc6679b