  Testbeams at MedAustron in 2025, Page 1 of 19  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  364   Sat Dec 13 21:47:18 2025 elog_producerKopf Phantom33Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 21:36:0413.12.2025 21:47:4411NormalRW3 Plate2cm+Kopf
automatic log for run 33
Comment:
sinus cavity spot 5mm down
identifier ba
mki: 310
sensor 4 seems to be dead, measure without it
  363   Sat Dec 13 21:35:30 2025 elog_producerKopf Phantom32Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Crap13.12.2025 21:26:4513.12.2025 21:35:569NormalKopf 
automatic log for run 32
Comment:
sinus cavity spot 5mm down
identifier ba
mki: 310
sensor 4 seems to be dead, measure without it
enabling preamps for sensor 1+2 is beneficial for data (21:35)
  362   Sat Dec 13 21:23:52 2025 elog_producerKopf Phantom31Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Crap13.12.2025 20:58:4513.12.2025 21:24:1725NormalRW3 Plate2cm+Kopf
automatic log for run 31
Comment:
sinus cavity spot 5mm down
identifier ba
mki: 310
(problems with HV at 21:00-21:15)
new threshold scan
  361   Sat Dec 13 20:24:58 2025 elog_producerenergy calibration30Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 20:10:4313.12.2025 20:25:2414NormalRW3 Plate12cm+3mm
automatic log for run 30
Comment:
2x ionization chambers
0.5mm Kapton
identifier j
mki: 310
  360   Sat Dec 13 20:04:41 2025 elog_producerenergy calibration29Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 19:49:0113.12.2025 20:05:0716NormalRW3 Plate12cm+3mm
automatic log for run 29
Comment:
2x ionization chambers
C only
identifier i
mki: 430
  359   Sat Dec 13 19:47:31 2025 elog_producerenergy calibration28Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 19:42:0013.12.2025 19:47:575NormalRW3 Plate12cm+3mm
automatic log for run 28
Comment:
2x ionization chambers
identifier h
mki: 310
(ramon start delayed Frown)
  358   Sat Dec 13 19:35:03 2025 elog_producerenergy calibration27Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 19:18:3313.12.2025 19:35:2916NormalRW3 Plate12cm+3mm
automatic log for run 27
Comment:
2x ionization chambers
identifier g
mki: 290
  357   Sat Dec 13 19:11:30 2025 elog_producerenergy calibration26Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 18:50:2113.12.2025 19:11:5621NormalRW3 Plate12cm+2mm
automatic log for run 26
Comment:
2x ionization chambers
identifier f
mki: 290
  356   Sat Dec 13 18:47:46 2025 elog_producerenergy calibration25Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 18:28:2213.12.2025 18:48:1219NormalRW3 Plate12cm+2mm
automatic log for run 25
Comment:
2x ionization chambers
identifier e
mki: 310
  355   Sat Dec 13 18:22:46 2025 elog_producerenergy calibration24Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 18:04:2513.12.2025 18:23:1118NormalRW3 Plate12cm
automatic log for run 24
Comment:
2x ionization chambers
identifier d
  354   Sat Dec 13 18:01:55 2025 elog_producerenergy calibration23Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 17:43:0713.12.2025 18:02:2119NormalRW3 Plate12cm
automatic log for run 23
Comment:
2x ionization chambers
identifier c
  353   Sat Dec 13 17:26:16 2025 elog_producerenergy calibration22Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 16:57:5913.12.2025 17:26:4128NormalRW3 Plate10cm
automatic log for run 22
Comment:
2x ionization chambers
identifier b
  352   Sat Dec 13 16:54:13 2025 elog_producerenergy calibration21Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 16:27:3413.12.2025 16:54:3927NormalRW3 Plate10cm
automatic log for run 21
Comment:
2x ionization chambers
same C setting now with He
identifier a
powercycle TDCs (16:43)
  351   Sat Dec 13 16:26:02 2025 elog_producerenergy calibration20Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 16:13:1013.12.2025 16:26:2813NormalRW3 Plate10cm
automatic log for run 20
Comment:
2x ionization chambers
start only He without dogma
Starts with only C (16:24)
  350   Sat Dec 13 16:00:08 2025 elog_producerenergy calibration19Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 15:02:1513.12.2025 16:00:3458NormalRW3 Plate11cm
automatic log for run 19
Comment:
2x ionization chambers
new threshold scan
1 spill 400MeV
downtime
  349   Sat Dec 13 14:48:42 2025 elog_producerenergy calibration18Sandwich-iCT setup(GSI)+RaMon200 MeV/ureduced_mixed_beamMixed Beam (He+C)Crap13.12.2025 14:43:1413.12.2025 14:49:075NormalRW3 Plate 
automatic log for run 18
Comment:
2x ionization chambers
detector 4 failed (problem with HV)
  348   Sat Dec 13 14:18:49 2025 elog_producerenergy calibration17Sandwich-iCT setup(GSI)+RaMon63.3 MeV/uLow Flux HighHeliumGood13.12.2025 14:02:3013.12.2025 14:19:1416NormalNone 
automatic log for run 17
Comment:
calibration run 63.3 MeV
  347   Sat Dec 13 14:00:52 2025 elog_producerenergy calibration16Sandwich-iCT setup(GSI)+RaMon73.2 MeV/uLow Flux HighHeliumGood13.12.2025 13:47:2313.12.2025 14:01:1813NormalNone 
automatic log for run 16
Comment:
calibration run 73.2 MeV
  346   Sat Dec 13 13:45:59 2025 elog_producerenergy calibration15Sandwich-iCT setup(GSI)+RaMon97.2MeV/uLow Flux HighHeliumGood13.12.2025 13:35:1213.12.2025 13:46:2411NormalNone 
automatic log for run 15
Comment:
calibration run 97.2 MeV
  345   Sat Dec 13 13:33:47 2025 elog_producerenergy calibration14Sandwich-iCT setup(GSI)+RaMon124.4 MeV/uLow Flux HighHeliumGood13.12.2025 13:24:4713.12.2025 13:34:139NormalNone 
automatic log for run 14
Comment:
alignment run 124.4 MeV