ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Datadown t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  181   Sat Dec 14 15:20:52 2024 Felix Ulrich-PurWET measurement slabs42TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux HighHeliumGood17:4818:0012 Dense Bone Slabs2cm

2cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

2.5MHz Ramon 250 kHz TRB

  182   Sat Dec 14 15:21:44 2024 Felix Ulrich-PurWET measurement slabs43TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux HighHeliumGood18:0418:1814 Dense Bone Slabs3cm

3cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

4MHz Ramon 1MHz TRB

  183   Sat Dec 14 15:23:21 2024 Felix Ulrich-PurWET measurement slabs44TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux HighHeliumGood18:1918:3314 Dense Bone Slabs2cm

3cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

4MHz Ramon 200kHz TRB

  184   Sat Dec 14 15:24:22 2024 Felix Ulrich-PurWET measurement slabs45TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux HighHeliumGood18:3718:5114 Dense Bone Slabs4cm

4cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

3MHz Ramon 800kHz TRB

  185   Sat Dec 14 15:25:12 2024 Felix Ulrich-PurWET measurement slabs46TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux HighHeliumGood18:5519:1116 Dense Bone Slabs4cm

4cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

2MHz Ramon 120kHz TRB

  186   Sat Dec 14 15:26:18 2024 Felix Ulrich-PurWET measurement slabs47TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux HighHeliumGood19:1619:2913 Dense Bone Slabs5cm

5cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

3MHz Ramon 300kHz TRB

  187   Sat Dec 14 15:27:08 2024 Felix Ulrich-PurWET measurement slabs48TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux HighHeliumGood19:3019:5020 Dense Bone Slabs5cm

5cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

1.5MHz Ramon

Wave crashes if 1 TDC disappears in dog d, DABC is still running

  188   Sat Dec 14 15:28:46 2024 Felix Ulrich-Purthreshold and preamp tests49TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood20:0420:095   

TRB Setup: 260V bias and 250mA pre-amps, threshold 10000 (was too high)

Diamond: 900mA, threshold 1000 offset

3.5MHz Ramon

  189   Sat Dec 14 15:30:23 2024 Felix Ulrich-Purthreshold and preamp tests50TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood20:1920:3516   

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000 (looks good, clustersize max at ~3)

Diamond: 900mA, threshold 1000 offset

4MHz Ramon 370kHz TRB

  190   Sat Dec 14 15:31:32 2024 Felix Ulrich-Purplastic mouse radiography51TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:1421:3016 plastic mouse 

before run, mouse was aligned with lasers and shift of beam w.r.t. sensor center was taken into account

pos x=250, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  191   Sat Dec 14 15:33:35 2024 Felix Ulrich-Purplastic mouse radiography53TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:3321:5724 plastic mouse 

run 52 was crap

pos x=175, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  192   Sat Dec 14 15:34:50 2024 Felix Ulrich-Purplastic mouse radiography54TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:5822:1022 plastic mouse 

pos x=100, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  193   Sat Dec 14 15:35:56 2024 Felix Ulrich-Purplastic mouse radiography55TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood22:1222:4533 plastic mouse 

pos x=25, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  194   Sat Dec 14 15:36:37 2024 Felix Ulrich-Purplastic mouse radiography56TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood22:4623:0014 plastic mouse 

pos x=-25, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  195   Sat Dec 14 15:37:26 2024 Felix Ulrich-Purplastic mouse radiography57TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:0223:1614 plastic mouse 

pos x=-100, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  196   Sat Dec 14 15:37:48 2024 Felix Ulrich-Purplastic mouse radiography58TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:1723:3013 plastic mouse 

pos x=-175, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  197   Sat Dec 14 15:39:11 2024 Felix Ulrich-Purplastic mouse radiography59TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:3323:4613 plastic mouse 

pos x=-175, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  198   Sat Dec 14 15:39:42 2024 Felix Ulrich-Purplastic mouse radiography60TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:5000:0818 plastic mouse 

pos x=-100, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  199   Sat Dec 14 15:40:09 2024 Felix Ulrich-Purplastic mouse radiography61TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:0900:2213 plastic mouse 

pos x=-25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  200   Sat Dec 14 15:40:45 2024 Felix Ulrich-Purplastic mouse radiography62TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:2200:3715 plastic mouse 

pos x=25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

ELOG V3.1.5-fc6679b