  119   Sun Aug 25 09:24:15 2024 tb-crewVNFB scan56RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 09:13:3525.08.2024 09:24:4211Normal  automatic log for run 56
Comment:
vnfb = 40
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  120   Sun Aug 25 09:35:54 2024 tb-crewVNFB scan57RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 09:25:4325.08.2024 09:36:2210Normal  automatic log for run 57
Comment:
vnfb = 50
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  121   Sun Aug 25 09:47:51 2024 tb-crewVNFB scan58RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 09:37:1325.08.2024 09:48:1811Normal  automatic log for run 58
Comment:
vnfb = 60
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  122   Sun Aug 25 09:58:51 2024 tb-crewonly base RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  removed Piggy connections   
  124   Sun Aug 25 10:06:51 2024 tb-crewonly base59RD50-MPW4800 MeVLow Flux Very LowProtonCrap25.08.2024 10:05:0125.08.2024 10:07:182Normal  automatic log for run 59
Comment:
reducing base threshold
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  125   Sun Aug 25 10:26:57 2024 tb-crewonly base60RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 10:12:0425.08.2024 10:27:2415Normal  automatic log for run 60
Comment:
normal statistic run; !!! en_tb_mode  was
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  126   Sun Aug 25 10:44:10 2024 tb-crewonly base61RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 10:28:1825.08.2024 10:44:3716Normal  automatic log for run 61
Comment:
normal statistic run
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  127   Sun Aug 25 10:58:26 2024 tb-crewonly base62RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 10:48:2725.08.2024 10:58:5310Normal  automatic log for run 62
Comment:
vnfb = 10
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  128   Sun Aug 25 11:09:44 2024 tb-crewonly base63RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 10:59:4225.08.2024 11:10:1110Normal  automatic log for run 63
Comment:
vnfb = 60
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  129   Sun Aug 25 11:16:09 2024 tb-crewonly base64RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 11:14:1925.08.2024 11:16:362Normal  automatic log for run 64
Comment:
experimental DAC settings
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  130   Sun Aug 25 11:19:53 2024 tb-crewonly base65RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 11:17:2225.08.2024 11:20:202Normal  automatic log for run 65
Comment:
experimental DAC settings
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  131   Sun Aug 25 11:31:49 2024 tb-crewonly base66RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 11:21:0625.08.2024 11:32:1611Normal  automatic log for run 66
Comment:
experimental DAC settings
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  132   Sun Aug 25 11:33:21 2024 tb-crewonly base RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  back to nominal DACs and thr   
  145   Sat Dec 14 12:54:55 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon6RaMon73.2 MeV/uLow Flux MediumHeliumGood06:3406:341   Mean rate per spill~ 4.5-8E5 p/s (online
estimation without proper analysis)
  
  152   Sat Dec 14 13:00:26 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon13RaMon73.2 MeV/uLow Flux HighHeliumGood06:4406:451   Mean rate per spill~ 4Ee6 p/s (online estimation
without proper analysis)
  
  163   Sat Dec 14 13:37:26 2024 Felix Ulrich-PurEnergy vs TOF calibration24TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon73.2 MeV/uLow Flux HighHeliumGood11:4212:0018   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

2MHz with Ramon and only 200kHz
  
  146   Sat Dec 14 12:55:41 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon7RaMon63.3 MeV/uLow Flux MediumHeliumGood06:3506:361   Mean rate per spill~ 2-5E5 p/s (online
estimation without proper analysis)
  
  153   Sat Dec 14 13:01:14 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon14RaMon63.3 MeV/uLow Flux HighHeliumGood06:4606:461   Mean rate per spill~ 5Ee6 p/s (online estimation
without proper analysis)
  
  164   Sat Dec 14 13:39:15 2024 Felix Ulrich-PurEnergy vs TOF calibration25TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood12:0512:2318   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

380 kHz with Ramon and only 180kHz
  
  165   Sat Dec 14 13:40:47 2024 Felix Ulrich-Purthreshold and preamp tests26TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood12:3512:4914   TRB Setup: 260V bias and 250mA pre-amps,
threshold 10000 (changed threshold)

Diamond: 500mA, threshold 50
  