184
|
Sat Dec 14 15:24:22 2024 |
Felix Ulrich-Pur | WET measurement slabs | 45 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 18:37 | 18:51 | 14 | | Dense Bone Slabs | 4cm |
4cm dense bone
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset
3MHz Ramon 800kHz TRB |
194
|
Sat Dec 14 15:36:37 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 56 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 22:46 | 23:00 | 14 | | plastic mouse | |
pos x=-25, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
195
|
Sat Dec 14 15:37:26 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 57 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:02 | 23:16 | 14 | | plastic mouse | |
pos x=-100, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
215
|
Sat Dec 14 15:49:12 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 77 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:22 | 04:36 | 14 | | plastic mouse | |
pos x=100, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
216
|
Sat Dec 14 15:49:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 78 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:36 | 04:50 | 14 | | plastic mouse | |
pos x=175, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
217
|
Sat Dec 14 15:49:58 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 79 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:51 | 05:05 | 14 | | plastic mouse | |
pos x=250, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
162
|
Sat Dec 14 13:35:59 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 23 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 124.4 MeV/u | Low Flux High | Helium | Good | 11:24 | 11:37 | 13 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
5MHz with Ramon and only 500kHz TRB |
171
|
Sat Dec 14 15:09:34 2024 |
Felix Ulrich-Pur | WET measurement slabs | 32 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 15:06 | 15:19 | 13 | | Plastic Water Slabs | 2cm |
2cm plastic water
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset
|
177
|
Sat Dec 14 15:17:10 2024 |
Felix Ulrich-Pur | WET measurement slabs | 38 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 16:42 | 16:55 | 13 | | Plastic Water Slabs | 5cm |
5cm plastic water
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset
2.5MHz Ramon 200 kHz TRB |
178
|
Sat Dec 14 15:17:57 2024 |
Felix Ulrich-Pur | WET measurement slabs | 39 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 17:00 | 17:14 | 13 | | Dense Bone Slabs | 1cm |
1cm dense bone
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset
4MHz Ramon 700 kHz TRB |
186
|
Sat Dec 14 15:26:18 2024 |
Felix Ulrich-Pur | WET measurement slabs | 47 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 19:16 | 19:29 | 13 | | Dense Bone Slabs | 5cm |
5cm dense bone
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset
3MHz Ramon 300kHz TRB |
196
|
Sat Dec 14 15:37:48 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 58 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:17 | 23:30 | 13 | | plastic mouse | |
pos x=-175, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
197
|
Sat Dec 14 15:39:11 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 59 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:33 | 23:46 | 13 | | plastic mouse | |
pos x=-175, posy=-75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
199
|
Sat Dec 14 15:40:09 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 61 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:09 | 00:22 | 13 | | plastic mouse | |
pos x=-25, posy=-75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
204
|
Sat Dec 14 15:42:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 66 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:21 | 01:34 | 13 | | plastic mouse | |
pos x=250, posy=75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
213
|
Sat Dec 14 15:48:26 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 75 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:52 | 04:05 | 13 | | plastic mouse | |
pos x=-25, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
69
|
Sat Mar 30 20:27:35 2024 |
hh, mb, ps | High statistics | 1052 | TJ-Monopix2 | 800 MeV | Low Flux Medium | Proton | Unknown | 30.03.2024 20:17:11 | 30.03.2024 20:30:02 | 12 | HV | | |
automatic log for run 1052
Comment:
Back to stock veto period of 7us (100) |
Attachment 1: tjmonopix2.conf
|
# example config file: Ex0.conf
[RunControl]
#pCT_STOP_RUN_AFTER_N_SECONDS = 3000000
# from the base RunControl.cc
#EUDAQ_CTRL_PRODUCER_LAST_START = my_pd0
#EUDAQ_CTRL_PRODUCER_FIRST_STOP = my_pd0
# Steer which values to display in the GUI: producerName and displayed value are seperated by a ",".
ADDITIONAL_DISPLAY_NUMBERS = "log,_SERVER"
[Producer.aida_tlu]
## GENERAL PARAMETERS
verbose= 1
skipconf= 0
confid= 20201311
delayStart= 200
## HDMI CONFIGURATION
# 4-bits to determine direction of HDMI pins
HDMI1_set= 0x7 #1= output (driven by TLU), 0 = input. bit 0=CONT, 1=SPARE, 2=TRIG, 3=BUSY for eudet, Busy needs to be 0. (0b0111 = 0x7)
HDMI2_set= 0x7
HDMI3_set= 0x7
HDMI4_set= 0x7
# Clock source (0= no clock, 1= Si5345, 2= FPGA)
HDMI1_clk = 0
HDMI2_clk = 0
HDMI3_clk = 0
HDMI4_clk = 0
# Enable/Disable clock on differential LEMO
LEMOclk = 0
## PMT POWER CONFIGURATION
PMT1_V= 0.8 #0.6363 #Szinti 4x4cm
PMT2_V= 0.8 #0.6363 #Szinti 4x4cm
PMT3_V= 0.0
PMT4_V= 0.0
## TRIGGER CONFIGURATION
trigMaskHi = 0x00000000
trigMaskLo = 0x00000008 #0x00000008 #0x00010002 #0x00000001 #8 coinc1+2
in0_STR = 0 # 0
in0_DEL = 0 # 18
in1_STR = 0 # 0
in1_DEL = 0 # 18
in2_STR = 0 # 0
in2_DEL = 0 # 0
in3_STR = 0
in3_DEL = 0
in4_STR = 0
in4_DEL = 0
in5_STR = 0 #streches pulse from 6.25ns (at 0) to 12.5ns
in5_DEL = 0
# Generate internal triggers (in Hz, 0= no triggers)
InternalTriggerFreq= 0 #4000 #00
## DISCRIMINATOR THRESHOLDS
DACThreshold0 = -0.025 #-0.025 #-0.012
DACThreshold1 = -0.012 #-0.025 #-0.012
DACThreshold2 = -0.012
DACThreshold3 = -0.12
DACThreshold4 = -0.12 #-0.0066
DACThreshold5 = -0.12
## DUT CONFIGURATION
# DUTMask Which DUTs are on
#DUTMask= 0x3 #6 bit 0= DUT1, bit 1= DUT2, bit 2= DUT3, bit 3= DUT4
DUTMask= 0xA
# DUTMaskMode Define AIDA (11) or EUDET (00) mode (2 bits per DUT)
DUTMaskMode= 0x00 #0x00
# In EUDET mode: 0 = standard trigger/busy mode, 1 = raising BUSY outside handshake vetoes triggers (2 bits per DUT, 0x3= DUT 4! -backwards!)
DUTMaskModeModifier= 0x30 #0x30 #0xC0 PS: Check what this does! 0x0 würde ich hier eingeben
# Ignore the BUSY signal for a DUT (0xF)
DUTIgnoreBusy= 0x0 #ignores triggers
DUTIgnoreShutterVeto= 0x0
EnableRecordData = 1
# EnableShutterMode: 0x0. If 1, shutter mode is enabled. If 0, shutter mode is disabled.
EnableShutterMode= 0x0
# Define which input is used for shutter source [0 - 5]
ShutterSource = 5
# 32-bit counter of clocks. Set to 0 to not use internal shutter generator.
InternalShutterInterval = 0
# 32-bit counter of clocks
ShutterOnTime = 0 #start of shutter after trigger
# 32-bit counter of clocks
ShutterVetoOffTime = 0 #time after input-trigger, until first trigger is sent to output
# 32-bit counter of clocks
ShutterOffTime = 200000000 #end of shutter after trigger #200000000 = 5s (multiples of 25ns)
## DATA COLLECTOR
EUDAQ_DC= tlu_dc
## TLU MONITOR PARAMETER
FileComment="mpw3"
PlotWindowSizeinns=40e9
MinSpillTimeOnins=4.5
MinSpilldownTimeins=0.5
ThreshEvBegin=1
ThreshEvEnd=1
ThreshPartBegin=1
ThreshPartEnd=1
[LogCollector.log]
# Currently, all LogCollectors have a hardcoded runtime name: log
# nothing
[DataCollector.tlu_dc]
EUDAQ_FW=native
# the format of data file
EUDAQ_FW_PATTERN= /home/silicon/Data/2024_03_MAUS/TLU/tlu_run$6R$X
# the name pattern of data file
# the $12D will be converted a data/time string with 12 digits.
# the $6R will be converted a run number string with 6 digits.
# the $X will be converted the suffix name of data file.
DISABLE_PRINT = 1
[Producer.tjmonopix2_AB]
# connection to the data collector
EUDAQ_DC = dc_tjmonopix2_AB
ENABLE_BDAQ_RECORD = 1
ENABLE_HITOR = 1
START_ROW = 0
STOP_ROW = 512
START_COLUMN = 448
STOP_COLUMN = 512
WAIT_FOR_FPGA = 1
[DataCollector.dc_tjmonopix2_AB]
EUDAQ_FW = native
EUDAQ_FW_PATTERN = /home/silicon/Data/2024_03_MAUS/TJ-Monopix2/raw/run$3R_tjmonopix2_AB_$12D$X
DISABLE_PRINT = 1
[Producer.tjmonopix2_CD]
# connection to the data collector
EUDAQ_DC = dc_tjmonopix2_CD
ENABLE_BDAQ_RECORD = 1
ENABLE_HITOR = 1
START_ROW = 0
STOP_ROW = 512
START_COLUMN = 448
STOP_COLUMN = 512
WAIT_FOR_FPGA = 1
[DataCollector.dc_tjmonopix2_CD]
EUDAQ_MN = monopix2_mon
EUDAQ_DATACOL_SEND_MONITOR_FRACTION = 1000
EUDAQ_FW = native
EUDAQ_FW_PATTERN = /home/silicon/Data/2024_03_MAUS/TJ-Monopix2/raw/run$3R_tjmonopix2_CD_$12D$X
DISABLE_PRINT = 1
[Producer.elog1]
#start_cmd = "./get_mpw4_configs.sh" # command (shell script) to execute before starting a run
#files2log = "peary_config.cfg, matrix_mpw4.txt" #files to attach to the auto Elog entries, EUDAQ config will be logged by default
|
172
|
Sat Dec 14 15:10:35 2024 |
Felix Ulrich-Pur | WET measurement slabs | 33 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 15:24 | 15:36 | 12 | | Plastic Water Slabs | 3cm |
3cm plastic water
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset
3-4MHz Ramon 600 kHz TRB |
175
|
Sat Dec 14 15:15:04 2024 |
Felix Ulrich-Pur | WET measurement slabs | 36 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 16:11 | 16:23 | 12 | | Plastic Water Slabs | 4cm |
4cm plastic water
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset
3MHz Ramon 300 kHz TRB |
176
|
Sat Dec 14 15:15:46 2024 |
Felix Ulrich-Pur | WET measurement slabs | 37 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 16:28 | 16:42 | 12 | | Plastic Water Slabs | 5cm |
5cm plastic water
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset
3-5MHz Ramon 500 kHz TRB |