Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 6 of 11  Not logged in ELOG logo
Entry  Sat Mar 30 11:55:55 2024, bp, ci, hh, useful datataking, 1023, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 11:06:49, 30.03.2024 11:58:22, 51, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1023
Comment:
Entry  Sat Mar 30 12:28:29 2024, bp, ci, hh, useful datataking, 1024, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 11:58:45, 30.03.2024 12:30:56, 32, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1024
Comment:
changed thr to 1V (not 100% sure, configure was not executed)
Entry  Sat Mar 30 12:54:24 2024, bp, ci, hh, useful datataking, 1025, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 12:32:27, 30.03.2024 12:56:51, 24, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1025
Comment:
changed thr to 0.95V
Entry  Sat Mar 30 13:28:15 2024, bp, ci, hh, useful datataking, 1026, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 12:58:02, 30.03.2024 13:30:42, 32, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1026
Comment:
changed thr to 0.98V
Entry  Sat Mar 30 13:35:09 2024, bp, ci, hh, useful datataking, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal, ,  
new users arrived
Entry is currently edited by RD50 Generic User on 193.170.243.131  Entry  Sun Aug 25 10:02:35 2024, RD50 Generic User, init_geo_file, , , , , , , , , , , ,  detectors.geo
position of duts needs to be switched
Entry  Mon Aug 26 09:18:25 2024, RD50 Generic User, geo, , , , , , , , , , , ,  detectors_new.geo
new geo file with adjusted dut position
Entry  Sat Jun 8 19:53:47 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Test High Rate, 1, TOF-Cal GSI, 252.7 MeV, Low Flux High, Proton, Good, 16:00, 16:18, , , ,  
7.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 2.5 MHz on LGAD
Entry  Sat Jun 8 19:56:37 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 2, TOF-Cal GSI, 252.7 MeV, Low Flux Medium, Proton, Good, 16:29, 16:47, , , ,  
1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350kHz on LGAD

TOF Calibration Curve
Entry  Sat Jun 8 19:57:39 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 3, TOF-Cal GSI, 194.3 MeV, Low Flux Medium, Proton, Good, 16:51, 17:28, , , ,  
600 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 235kHz on LGAD

TOF Calibration Curve
Entry  Sat Jun 8 20:05:27 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 4, TOF-Cal GSI, 175.3 MeV, Low Flux Medium, Proton, Good, 17:31, 17:54, , , ,  
500 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 170kHz on LGAD

TOF Calibration Curve
Entry  Sat Jun 8 20:07:44 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 5, TOF-Cal GSI, 145.4 MeV, Low Flux Medium, Proton, Good, 17:55, 18:24, , , ,  
400 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 120kHz on LGAD

TOF Calibration Curve
Entry  Sat Jun 8 20:08:55 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 6, TOF-Cal GSI, 115.7MeV, Low Flux Medium, Proton, Good, 18:24, 19:00, , , ,  
400 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD

TOF Calibration Curve
Entry  Sat Jun 8 20:09:25 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 7, TOF-Cal GSI, 100.4 MeV, Low Flux Medium, Proton, Good, 19:00, 19:42, , , ,  
300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD

TOF Calibration Curve
Entry  Sat Jun 8 20:11:00 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 8, TOF-Cal GSI, 83 MeV, Low Flux Medium, Proton, Good, 19:42, 20:51, , , ,  
300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 35kHz on LGAD

TOF Calibration Curve
Entry  Sat Jun 8 21:41:04 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 9, TOF-Cal GSI, 62.4 MeV, Low Flux High, Proton, Good, 20:55, 21:21, , , ,  
changed back to high due to beamsize vs LGAD size factor
650 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230kHz on LGAD

TOF Calibration Curve
Entry  Sat Jun 8 21:42:13 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 10, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 21:27, 21:39, , , ,  
1cm plastic water (in isocentre)
6 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.5 MHz on LGAD

WET measurement
Entry  Sat Jun 8 21:43:26 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 11, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 21:39, 21:48, , , ,  
1cm plastic water (in isocentre)
4 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 700 kHz on LGAD

WET measurement
Entry  Sat Jun 8 21:54:59 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 12, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 21:53, 22:05, , , ,  
2cm plastic water (in isocentre)
5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD

WET measurement
Entry  Sat Jun 8 22:12:06 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 13, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 22:05, 22:34, , , ,  
2cm plastic water (in isocentre)
3.2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement
ELOG V3.1.5-fc6679b