Sat Dec 14 15:46:16 2024, Felix Ulrich-Pur, plastic mouse radiography, 71, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 02:46, 03:03, 17, , plastic mouse,
|
pos x=-100, posy=75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sun Aug 25 10:44:10 2024, tb-crew, only base, 61, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 10:28:18, 25.08.2024 10:44:37, 16, Normal, ,
|
automatic log for run 61
Comment:
normal statistic run |
Sat Dec 14 15:25:12 2024, Felix Ulrich-Pur, WET measurement slabs, 46, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 18:55, 19:11, 16, , Dense Bone Slabs, 4cm
|
4cm dense bone
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:30:23 2024, Felix Ulrich-Pur, threshold and preamp tests, 50, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 20:19, 20:35, 16, , ,
|
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000 (looks good, clustersize max at ~3)
Diamond: 900mA, threshold 1000 offset
4MHz Ramon 370kHz TRB |
Sat Dec 14 15:31:32 2024, Felix Ulrich-Pur, plastic mouse radiography, 51, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 21:14, 21:30, 16, , plastic mouse,
|
before run, mouse was aligned with lasers and shift of beam w.r.t. sensor center was taken into account
pos x=250, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000 |
Sat Dec 14 15:43:01 2024, Felix Ulrich-Pur, plastic mouse radiography, 67, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 01:35, 01:51, 16, , plastic mouse,
|
pos x=175, posy=75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:43:45 2024, Felix Ulrich-Pur, plastic mouse radiography, 68, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 01:51, 02:07, 16, , plastic mouse,
|
pos x=100, posy=75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:46:54 2024, Felix Ulrich-Pur, plastic mouse radiography, 72, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 03:03, 03:19, 16, , plastic mouse,
|
pos x=-175, posy=75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:47:59 2024, Felix Ulrich-Pur, plastic mouse radiography, 74, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 03:35, 03:51, 16, , plastic mouse,
|
pos x=-100, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Mar 30 07:59:41 2024, bp, ci, hh, RD50-MPW4, 1006, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, 30.03.2024 07:46:50, 30.03.2024 08:02:08, 15, Normal, ,
|
automatic log for run 1006
Comment:
beautifully correlated :D |
Sun Aug 25 08:51:02 2024, tb-crew, VNFB scan, 53, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 08:36:24, 25.08.2024 08:51:28, 15, Normal, ,
|
automatic log for run 53
Comment:
vnfb = 10 |
Sun Aug 25 10:26:57 2024, tb-crew, only base, 60, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 10:12:04, 25.08.2024 10:27:24, 15, Normal, ,
|
automatic log for run 60
Comment:
normal statistic run; !!! en_tb_mode was set to 0 -> possibly sync problem |
Sun Aug 25 12:39:45 2024, tb-crew, only base, 70, RD50-MPW4, 100.4 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 12:24:36, 25.08.2024 12:40:12, 15, Normal, ,
|
automatic log for run 70
Comment:
E-scan |
Sat Dec 14 13:31:49 2024, Felix Ulrich-Pur, Energy vs TOF calibration, 21, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 10:41, 10:56, 15, , ,
|
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
3.5MHz with Ramon and only 600kHz with TRB-52ps single channel res prae calib |
Sat Dec 14 15:40:45 2024, Felix Ulrich-Pur, plastic mouse radiography, 62, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 00:22, 00:37, 15, , plastic mouse,
|
pos x=25, posy=-75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:48:49 2024, Felix Ulrich-Pur, plastic mouse radiography, 76, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 04:06, 04:21, 15, , plastic mouse,
|
pos x=25, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 13:40:47 2024, Felix Ulrich-Pur, threshold and preamp tests, 26, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 63.3 MeV/u, Low Flux High, Helium, Good, 12:35, 12:49, 14, , ,
|
TRB Setup: 260V bias and 250mA pre-amps, threshold 10000 (changed threshold)
Diamond: 500mA, threshold 50 |
Sat Dec 14 15:18:48 2024, Felix Ulrich-Pur, WET measurement slabs, 40, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 17:14, 17:28, 14, , Dense Bone Slabs, 1cm
|
1cm dense bone
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:21:44 2024, Felix Ulrich-Pur, WET measurement slabs, 43, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 18:04, 18:18, 14, , Dense Bone Slabs, 3cm
|
3cm dense bone
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:23:21 2024, Felix Ulrich-Pur, WET measurement slabs, 44, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 18:19, 18:33, 14, , Dense Bone Slabs, 2cm
|
3cm dense bone
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
Diamond: 900mA, threshold 1000 offset |
|