ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
95
|
Sun Jun 9 01:26:56 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 24 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 01:02 | 01:14 | | |
2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 315 kHz on LGAD
WET measurement |
96
|
Sun Jun 9 01:27:38 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 25 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 01:16 | 01:30 | | |
3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD
WET measurement |
97
|
Sun Jun 9 01:32:51 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 26 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 01:30 | 01:45 | | |
3 cm dense bone (in isocentre)
1.7 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230 kHz on LGAD
WET measurement |
98
|
Sun Jun 9 01:48:51 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 27 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 01:48 | 01:59 | | |
4 cm dense bone (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 470 kHz on LGAD
WET measurement |
100
|
Sun Jun 9 02:02:16 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 28 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 02:00 | 02:14 | | |
4 cm dense bone (in isocentre)
1.4 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 175 kHz on LGAD
WET measurement |
101
|
Sun Jun 9 02:18:55 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 29 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 02:18 | | | |
5 cm dense bone (in isocentre)
1.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350 kHz on LGAD
WET measurement |
10
|
Sat Mar 30 07:59:55 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | | | | Normal |
currently no beam |
15
|
Sat Mar 30 08:40:10 2024 |
bp, ci, hh | RD50-MPW4 | 1008 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | 30.03.2024 08:37:03 | 30.03.2024 08:42:37 | 5 | Normal |
automatic log for run 1008
Comment:
waiting for beam |
16
|
Sat Mar 30 08:56:25 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | | | | Normal |
waiting for beam
Performing MTS restart |
17
|
Sat Mar 30 09:03:54 2024 |
bp, ci, hh | RD50-MPW4 | 1009 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | 30.03.2024 08:43:22 | 30.03.2024 09:06:20 | 22 | Normal |
automatic log for run 1009
Comment:
waiting for beam
Performing MTS restart |
18
|
Sat Mar 30 09:15:13 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | | | | Normal |
moved entire setup a bit in order too better focus beam on MPW4 (hopefully) |
19
|
Sat Mar 30 09:25:05 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | | | | Normal |
bea is back |
20
|
Sat Mar 30 09:27:33 2024 |
bp, ci, hh | RD50-MPW4 | 1010 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | 30.03.2024 09:23:42 | 30.03.2024 09:29:59 | 6 | Normal |
automatic log for run 1010
Comment: |
31
|
Sat Mar 30 10:23:06 2024 |
bp, ci, hh | RD50-MPW4 | 1017 | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Crap | 30.03.2024 10:25:09 | 30.03.2024 10:25:33 | 0 | Normal |
automatic log for run 1017
Comment:
changed rate to low again, too much "noise"
also moved table down and a bit to the left
no HV, is crap |
32
|
Sat Mar 30 10:25:55 2024 |
bp, ci, hh | RD50-MPW4 | 1018 | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Crap | 30.03.2024 10:26:17 | 30.03.2024 10:28:21 | 2 | Normal |
automatic log for run 1018
Comment: |
33
|
Sat Mar 30 10:27:56 2024 |
bp, ci, hh | RD50-MPW4 | 1019 | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Crap | 30.03.2024 10:28:28 | 30.03.2024 10:30:22 | 1 | Normal |
automatic log for run 1019
Comment: |
64
|
Sat Mar 30 18:59:16 2024 |
hh, mb, ps | 1st tests | 1047 | TJ-Monopix2 | 800 MeV | Low Flux Low | Proton | Crap | 30.03.2024 19:00:11 | 30.03.2024 19:01:43 | 1 | HV |
automatic log for run 1047
Comment:
Test if we get beam, MAUS has problems |
87
|
Sun Jun 9 00:05:11 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser (wrong energy) | 16 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Crap | 22:50 | 22:52 | | |
wrong energy don't use |
1
|
Sat Mar 30 06:34:39 2024 |
Bernhard Pilsl | And a new testbeam starts :D | | | | | | | | | | |
|
11
|
Sat Mar 30 08:05:59 2024 |
Christian Irmler | RD50-MPW4 | 999 | | | | | | | | | |
Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml
Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting. |